![Lantech IES-5222T Series User Manual Download Page 7](http://html1.mh-extra.com/html/lantech/ies-5222t-series/ies-5222t-series_user-manual_675557007.webp)
6
Jumbo frame
9KB on all ports
Connector
10/100TX: 22 x M12 4-pole D-coded with auto MDI/MDI-X
function
10/100/1000T: 2 x M12 8-pole A-coded with auto
MDI/MDI-X function
RS-232 connector: 1 x M12 5-pole A-coded
Power Input connector : 1 x M12 5-pole A-coded
Relay contact : 1 x M12 5-pole A-coded
Network Cable
10Base-T: 2-pair UTP/STP Cat. 3, 4, 5 cable
EIA/TIA-568 100-ohm (100m)
100Base-TX: 2-pair UTP/STP Cat. 5/ 5E cable
EIA/TIA-568 100-ohm (100m)
Protocol
CSMA/CD
Bypass
Protection**
High-speed optical switching (<4ms)
Minimal insertion loss (Max 1.6dB as Bypass Mode)
LED
Per unit: Power 1 (Green), Power 2 (Green), P-Fail (Red)
Ethernet port: Link/Activity (Green), Speed (Green); GigaT:
Link/Activity (Green)
DI / DO
1 Digital Input (DI) :
Level 0: -30~2V / Level 1: 10~30V
Max. input current:8mA
1 Digital Output(DO): Open collector to 40 VDC, 200mA
Operating
Humidity
5% ~ 95% (Non-condensing)
Operating
Temperature
-40°C~75°C / -40°F~167°F
Storage
Temperature
-40°C~85°C / -40°F~185°F
Power Supply
Standard model:9.5~60VDC dual input
72V model: 50.4~90VDC dual input
110V model: 43~137.5VDC dual input
Power
Consumption
Max. 16W
Summary of Contents for IES-5222T Series
Page 11: ...10 Future release Optional...
Page 18: ...17 Off No device attached...
Page 26: ...25 4 3 Multiple Rings...
Page 27: ...26 4 4 Dual Homing 4 5 Chain...
Page 28: ...27...