Lantech IES-3 Series User Manual Download Page 20

 

19

 

3.7  Cabling 

 

 

Use  four  twisted-pair,  Category  5e  or  above  cabling  for  RJ-45  port  connection. 

The cable between the switch and the link partner (switch, hub, workstation, etc.) 

must be less than 100 meters (328 ft.) long. 

 

Fiber  segment  using 

single-mode

  connector  type  must  use9/125  µm  single-

mode fiber cable. User can connect two devices in the distance up to 

30km

 

Fiber  segment  using 

multi-mode

  connector  type  must  use  50  or  62.5/125  µm 

multi-mode fiber cable. User can connect two devices up to 

2km

distances. 

 

Gigabit / 100M SFP port:

 

The  small  form-factor  pluggable  (SFP)  is  a  compact  optical  transceiver  used  in 

optical  communications  for  both  telecommunication  and  data  communications.  The 

SFP  slots  supporting  Gigabit  speed  up  to  1000Mbps. 

–DSFP/-DFT models  support 

dual  speed  100M  or  1000Mbps.    They  are  used  for  connecting  to  the  network 

segment  with  single  or  multi-mode  fiber.  You  can  choose  the  appropriate  SFP 

transceiver  to  plug  into  the  slots.  Then  use  proper  multi-mode  or  single-mode  fiber 

according to the transceiver. With fiber optic, it transmits at speed up to 1000 Mbps 

or dual speed (-DSFP/-DFT models) and you can prevent noise interference from the 

system. 

 

To connect the transceiver and LC cable, please follow the steps shown below: 

 

First, insert the transceiver into the SFP module. Notice that the triangle mark is the 

bottom of the module. 

Summary of Contents for IES-3 Series

Page 1: ...ES 3XXX I P ES 5XXX IP30 rated Series IP30 rated DIN Rail L2 Industrial Managed Switch User Manual Hardware For 19 inch rack mount models please refer to hardware manual with specific model name Oct 2...

Page 2: ...y an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where la...

Page 3: ...consent of Lantech Communications Global Inc Products offered may contain software which is proprietary to Lantech Communications Global Inc The offer or supply of these products and services does no...

Page 4: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...

Page 5: ...ardware installation 10 3 2 DIN Rail Mounting 12 3 3 Wall Mount Plate Mounting 14 3 4 Wiring the Power Inputs 15 3 4 1 For 12V 24V 48V models 15 3 4 2 For HV models 16 3 5 Wiring the Fault Alarm Conta...

Page 6: ...Rating classifies and rates the degree of protection provided against the intrusion including body parts such as hands and fingers dust accidental contact and water in mechanical casings and with elec...

Page 7: ...of protection that the enclosure provides against harmful ingress of water Level Protected against Testing for Details 0 Not protected 1 Dripping water Dripping water vertically falling drops shall ha...

Page 8: ...against the enclosure from any direction shall have no harmful effects Test duration at least 3 minutes Water volume 100 litres per minute Pressure 100 kPa at distance of 3 m 7 Immersion up to 1 m In...

Page 9: ...ide real time information of system and optional status are located on the front panel of the industrial switch The following table provides the description of the LED status and their meanings for th...

Page 10: ...device Off No device attached PoE FWD For PoE model Off The port is not operating in PoE mode On The port is operating in PoE mode SFP Port LED On A network device is detected Blinking The port is tra...

Page 11: ...se refer to Wall Mount Plate Mounting section for wall mount plate installation NOTE Wall mount kits are optional accessories 3 To hang the Industrial switch on the DIN Rail track or wall 4 Power on t...

Page 12: ...e Please refer to the LED Indicators section for LED light indication NOTE Make sure that the connected network devices support MDI MDI X If it does not support use the crossover category 5 cable 7 Wh...

Page 13: ...l is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following pictures to screw the DIN Rail on the switch Follow the steps...

Page 14: ...sert the top of DIN Rail into the track 2 Then lightly push the DIN Rail into the track 3 Check if the DIN Rail is tightened on the track or not 4 To remove the industrial switch from the track revers...

Page 15: ...s to remove the DIN Rail 2 Place the wall mount plate on the rear panel of the industrial switch 3 Use the screws to screw the wall mount plate on the industrial switch 4 Use the hook holes at the cor...

Page 16: ...the contacts 1 and 5 with negative electrode of power and 2 and 6 with positive electrode of power contacts 1 and 2 are defined as power input 1 and contacts 5 and 6 are defined as power input 2 you...

Page 17: ...e electrode of power and 6 with positive electrode of power the HV models are single power design Tighten the wire clamp screws for preventing the wires from loosing Using AC power AC power resource h...

Page 18: ...e switch will detect the fault status of the power failure or port link failure available for managed model and then forms an open circuit The following illustration shows an application example for w...

Page 19: ...d 2DO DI Digital input DO Digital output When disconnection of the specific port was detected DO will activate the signal LED to alarm DI can integrate the sensors for events and DO will trigger the a...

Page 20: ...ct optical transceiver used in optical communications for both telecommunication and data communications The SFP slots supporting Gigabit speed up to 1000Mbps DSFP DFT models support dual speed 100M o...

Page 21: ...20 Transceiver to the SFP module Transceiver Inserted Second insert the fiber cable of LC connector into the transceiver...

Page 22: ...21 LC connector to the transceiver...

Page 23: ...follow the steps shown below First press the upper side of the LC connector to release from the transceiver and pull it out Remove LC connector Second push down the metal loop and pull the transceive...

Page 24: ...or Attach the end of RS 232 connector to PC or terminal and the other end of RJ 45 connector to the console port of the switch The connected terminal or PC must support the terminal emulation program...

Page 25: ...f the console port Baud Rate 115200 bps Data Bits 8 Parity none Stop Bit 1 Flow control None The settings of communication parameters Having finished the parameter settings click OK When the blank scr...

Page 26: ...25 Console login interface Notice For web based management please refer to our Software Management Manual Please contact support lantechcom tw for more information...