background image

 

 

 

Lantech 

IES-0008-M12 

8 10/100TX IP41 rated Industrial Switch   

w/M12 connectors 

User Manual 

     

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for IES-0008-M12

Page 1: ...Lantech IES 0008 M12 8 10 100TX IP41 rated Industrial Switch w M12 connectors User Manual...

Page 2: ...acking List 5 Safety Precaution 5 Hardware Description 6 Physical Dimensions 6 Front Panel 7 LED Indicators 8 Fast Ethernet Ports 9 Pinouts of the Power Connector 10 Installation 11 Wall Mounting 11 D...

Page 3: ...Power Inputs The redundant power input design for the Ethernet switch gives a backup power solution With both the power inputs supplied if either one fails the other one will be activated to keep the...

Page 4: ...s Back plane switching fabric 1 6Gbps M12 connectors and IP41 metal housing Wide range redundant power design Wide operating temperature 40 75 C EN50155 50121 3 2 50121 4 Auto Bypass between Port 1 an...

Page 5: ...e Connectors 8 x M12 4 pole D coded female 10 100TX with the bypass function P1 and P2 1 x M12 5 pole A coded male Power LED Indicators System PWR1 PWR2 10 100Base TX port LNK ACT Power Power Consumpt...

Page 6: ...L 60950 EMC CE FCC Class A CE EN61000 4 2 ESD CE EN61000 4 3 RS CE EN61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6 CS CE EN61000 4 8 Magnetic Field CE EN61000 6 2 CE EN61000 6 4 Railway Traffic EN...

Page 7: ...p with screws 1 x User Manual CD ROM Compare the contents of the Ethernet switch with the standard checklist above If any item is damaged or missing please contact the local dealer for service Safety...

Page 8: ...section is intended to introduce the Ethernet switch s dimensions definitions of LED indicators and connector pinouts Physical Dimensions The figure below illustrates the dimensions for the Ethernet S...

Page 9: ...7 Front Panel The figure shown below is the Front Panel of the Ethernet switch Front Panel...

Page 10: ...witch Please refer to the following table for further details LED Color Description PWR1 Green On Power input 1 is active Off Power input 1 is inactive PWR2 Green On Power input 2 is active Off Power...

Page 11: ...auto sensing for 10Base T or 100Base TX devices connections Auto MDI MDIX means that you can connect to another switch or workstation without changing straight through or crossover cabling M12 D code...

Page 12: ...Ethernet connection Connect the positive and negative wires to PWR1 V1 V1 and PWR2 V2 V2 as the power pin assignments shown below Power1 Power2 Contacts of the M12 Connector Only trained and qualifie...

Page 13: ...all mount plates and six screws included 2 Align the screw holes between the wall mount plates and the unit as the figure illustrated 3 Secure the plates to the unit with the accompanying screws 4 Hav...

Page 14: ...d 2 Align the screw holes between the clip and the unit as the figure illustrated 3 Secure the DIN rail clip to the unit with the accompanying screws 4 After you have secured the DIN rail clip to the...

Page 15: ...Ethernet switch to ground When installing the Ethernet switch the ground connection must always be made first and disconnected last 1 Locate and remove the dome screw which has a ground symbol beside...

Page 16: ...h describes common problems you may encounter and where you can find possible solutions to assist in identifying problems If the power indicator does not light up when the power cord is plugged in you...

Reviews: