uni-cast or multi-cast data from the serial device server to host computers, and the serial 

device can also receive data from one or multiple host. 

 

 

Label 

Description 

Listen Port 

Allows the user to set a new TCP port number to listen on rather 

than the default value of the device

 

Host Start/End IP 

If  there  are  more  than  one  destination  hosts,  specify  the  IP 

address  range  by  inputting  a  value  in 

Host  Start 

End  IP

.  You 

can also auto scan the sending port number of the device

 

Send Port 

Set the send port number.

 

Management 

Access IP Control 

 

Access IP Control List allows you to add or block remote host IP addresses to prevent 

unauthorized access. If a 

host’s IP address is in the accessible IP table, the host will be 

allowed to access the DS. You can check     

Summary of Contents for IDS-2102A

Page 1: ...IDS 2102A User s Manual 1 RS 232 422 485 port to 2 10 100TX Ethernet Device Server May 2018 Version 1 10...

Page 2: ...Hardware Installation 8 3 1 DIN rail Installation 8 3 2 Wall Mounting 9 3 3 Wiring 10 3 3 1 Grounding 10 3 3 2 Redundant Power Inputs 11 3 4 Connection 11 3 4 1 Cables 11 10 100BASE T X Pin Assignmen...

Page 3: ...IDS 2102A User s Manual Lantech Communications Global Inc 2 System 32 Port Serial Setting 36 Management 43 Save Reboot 47 4 3 Configuration by SSH Console 48 4 3 1 Connect to DS 48...

Page 4: ...ncy in case of Ethernet connection breakdown or host PC failure Further the device supports HTTPS SSH and SSL encryption to assure the security of critical data transmission Software Features Supports...

Page 5: ...IDS 2102A User s Manual Lantech Communications Global Inc 4 Casing IP 30 Dimensions 26 W x 75 D x 110 H mm...

Page 6: ...ports on the top panel The Ethernet port on the device use RJ 45 connectors Port Description Copper port 2 x 10 100Base T X port one is PoE enabled Serial port 1 x DB9 serial ports IDS 2102A 1 Power...

Page 7: ...n On Ethernet port link up TX RX Red On Receiving data Green On Transmitting data 2 2 Top Panel Below are the top panel components of the device 1 Terminal blocks PWR1 PWR2 2 Reset default button 3 Gr...

Page 8: ...IDS 2102A User s Manual Lantech Communications Global Inc 7...

Page 9: ...low you to fasten the device to a DIN rail in any environments DIN rail Kit Measurement unit mm Installing the device on the DIN rail is easy First screw the Din rail kit onto the back of the device r...

Page 10: ...n rail the device can be fixed to the wall via wall mount kits which can be found in the package Wall Mount Kit Measurement unit mm Follow the steps below to install the device to a rack Step 1 Instal...

Page 11: ...could overheat causing serious damage to your equipment 4 Use separate paths to route wiring for power and devices If power wiring and device wiring paths must cross make sure the wires are perpendicu...

Page 12: ...ments The device has two standard Ethernet ports According to the link type the device uses CAT 3 4 5 5e UTP cables to connect to any other network devices PCs servers switches routers or hubs Please...

Page 13: ...transmit RD receive 3 RD receive TD transmit 4 Not used Not used 5 Not used Not used 6 RD receive TD transmit 7 Not used Not used 8 Not used Not used Note and signs represent the polarity of the wire...

Page 14: ...DS series It supports device discovery device configuration group setup group firmware update and monitoring functions The tool enables you to easily install and configure devices on the network 4 1 1...

Page 15: ...checking Launch DS Tool Later 4 1 2 Using DS Tool Explore device servers DS Tool will broadcast to the network and search all available DS devices in the network automatically The default IP address o...

Page 16: ...r s Manual Lantech Communications Global Inc 15 4 1 3 Configure Device Servers General This page enables you to perform general configuration for the device includes the device name SNTP server and au...

Page 17: ...on such as the SNTP server domain name or IP address and the port number and select a time zone Auto IP Report Check the Auto IP Report box if you want to receive IP report regularly By Clicking the G...

Page 18: ...our server Factory default is no password Ethernet You must assign a valid IP address for DS before attached in your network environment Your network administrator should provide you the IP address an...

Page 19: ...network must have the same subnet mask to communicate on the network Gateway Enter the IP address of the router in you network DNS1 2 Enter the IP addresses of the primary and secondary DNS servers T...

Page 20: ...s to use for sending emails if the box is checked Syslog Notification Check the box to allow the system to send a detailed log to an external Syslog server when an event occurs The syslog will capture...

Page 21: ...gger the event Password Changed Changing the password will trigger the event Access IP Blocked Report blocked IP addresses System Log Settings You can specify the server IP address and port or click U...

Page 22: ...checked you need to fill in the SNMP settings in these fields by assigning the Community Location Contact and Trap Server Upgrade Firmware You can find up to date firmware from support lantechcom tw T...

Page 23: ...again in order to search the device warm start Import Configuration Click this button will retrieve saved configuration file and apply it to in current device Export Configuration Saving the current...

Page 24: ...ing the baud rate to 9600bps the serial port will transfer a maximum of 9600 bits per second You can select a baud rate from the drop down list which ranges from 110bps to 460800bps Parity Parity is a...

Page 25: ...be configured to transmit the same number of stop bits Flow Control Serial communication consists of hardware flow control and software flow control so called as the control is handled by software or...

Page 26: ...r The received data will be queuing in the buffer until all the delimiters are matched When the buffer is full 4K Bytes or after flush S2E data buffer timeout the data will also be sent You can set th...

Page 27: ...ault value If multilink is configured only the first host connection is effective for this setting Alive Check The serial device will send a TCP alive check package in each defined time interval Alive...

Page 28: ...number for data transmission Auto Scan Scan the data port automatically Idle Timeout When a serial port stops data transmission for a defined period of time Idle Timeout the connection will be closed...

Page 29: ...character After the data has been transferred the device can disconnect automatically from the server by using the TCP alive check time or idle time settings Label Description Destination Host Input t...

Page 30: ...evice is started Connect on Any Character The TCP Client will build a TCP connection once the connected serial device starts to send data UDP Mode Compared to TCP communication UDP is faster and more...

Page 31: ...Carrier Detect signal changes it indicates that the modem connection status has changed A notification will be sent if the box is checked DSR changed When DSR Data Set Ready signal changes it indicate...

Page 32: ...a built in web server which supports Internet Explorer Internet Explorer 5 0 or above versions and other Web browsers such as Chrome Therefore you can manage and configure the device easily and remote...

Page 33: ...device as below On the left hand side of the management interface shows links to various settings Clicking on the links will bring you to individual configuration pages 4 2 1 Settings System Time SNTP...

Page 34: ...t location time zones for your reference Local Time Zone Conversion from UTC Time at 12 00 UTC November Time Zone 1 hour 11 am Oscar Time Zone 2 hours 10 am ADT Atlantic Daylight 3 hours 9 am AST Atla...

Page 35: ...ustralian 10 hours 10 pm Standard GST Guam Standard USSR Zone 9 IDLE International Date Line NZST New Zealand Standard NZT New Zealand 12 hours Midnight IP Configuration This page allows you to config...

Page 36: ...viders Enter the PPPoE login user name and password which should have been provided to you by your ISP IP Address Enter the IP address that identifies the server on the TCP IP network Netmask Enter a...

Page 37: ...to set up login account and password You can also change your password in this page Label Description Old Password Enter the existing password that is used to log in New Password Enter a new password...

Page 38: ...data bits to be 7 or 8 Data is transmitted as a series of five six seven or eight bits five and six bit data formats are used rarely for specialized communications equipment Stop Bits Choose the numb...

Page 39: ...ding data then the receiving side will send an XOFF character over its Tx line to tell the transmitting side to stop transmitting Choose XON to tell the computer to begin sending data again then the r...

Page 40: ...onds Delimiter For advanced data packing options you can specify delimiters for Serial to Ethernet and or Ethernet to Serial communications You can define max 4 delimiters 00 FF Hex for each way The d...

Page 41: ...to remote host to check the TCP connection If the TCP connection is not alive the connection will be closed and the port will be freed 0 indicate disable this function Factory default is 0 Max Connec...

Page 42: ...ed time interval Alive Check to remote host to check the TCP connection If the TCP connection is not alive the connection will be closed and the port will be freed 0 indicate disable this function Fac...

Page 43: ...configured only the first host connection is effective for this setting Alive Check The serial device will send TCP alive check packages in each defined time interval to remote host to check the TCP...

Page 44: ...the default value of the device Host Start End IP If there are more than one destination hosts specify the IP address range by inputting a value in Host Start End IP You can also auto scan the sendin...

Page 45: ...1 255 255 255 255 Netmask Only the host on the specified subnet can access the device server The format should be IP address 255 255 255 0 e g 192 168 0 1 255 255 255 0 SMTP SNMP Conf Email server co...

Page 46: ...User s Manual Lantech Communications Global Inc 45 System Event Conf Specify the events that will be reported to the administrator The notifications of the events can be done via e mail SNMP trap or s...

Page 47: ...rming a warm start DS will automatically send an e mail log or SNMP trap after rebooting Login Failed When unauthorized access from the console or Web interface occurs a notification will be sent IP A...

Page 48: ...ection this event will be triggered In TCP Client Mode when the device has connected to the remote host the event will be triggered In Virtual COM Mode when Virtual COM is ready to use this event will...

Page 49: ...iguration Restore to previous settings using previously exported configurations Backup Configuration Export the current configuration to a file Upgrade Firmware Upgrade to a new firmware by browsing t...