11. WARRANTY
Limited Consumer Product
Warranty
While we take great care and pride in ensuring that our
products are of the highest quality, we recognise that
very occasionally things may go wrong.
Our guarantee covers any faults which affect the performance of the pump mechanism for 1 year and other product
components of our breast pump for 90 days.
This guarantee does not apply to cosmetic, accidental damage, improper use, incorrect voltage use, everyday wear
and tear, faults or damage that are a result of your misuse of the pump, and pumps which have been modified or
multiple-person use.
This guarantee applies to customers in the UK. For health and hygiene reasons our breast pumps should not be
re-sold, and our guarantee does not apply to any subsequent owners.
Where your breast pump develops a fault that is covered by our guarantee we will repair or replace the breast pump
or the affected parts. This may mean we provide one or more replacement parts to you. We may ask you to return
the pump and/or faulty components for testing or repair.
To make a claim under this guarantee, you should tell us about the fault by contacting us at
lansinoh.co.uk/
contact-us/
. You will need to provide us with proof of purchase of the breast pump or parts. We will then
notify you of next steps.
YOUR STATUTORY RIGHTS ARE NOT AFFECTED.
For more information on your rights contact your local consumer advice centre or go online.
This guarantee is provided by Lansinoh Laboratories Inc, Ground Floor, West Mayesbrook
House, Lawnswood Business Park, Leeds, LS16 6QY.
Declaration for Electromagnetic Compatibility (EMC)
For information use only
FCC Statement: This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause
undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy, and if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there
is no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
Stacking:
This device should not be used adjacent to or stacked with other equipment. And
if adjacent or stacked use is necessary, this device should be observed to verify normal
operation in the configuration in which it will be used.
Disposal:
The symbol which can be found on the product or on the package surface indicates
that the product shall not be disposed with other household wastes. It is the users responsibility to
properly dispose of the product, or facilitate recycling activities. For further information about the
recycling collection points, please contact your local authority or Lansinoh Customer Service.
Technical Data
Bluetooth version 4.1
Range up to 10m
Power Requirements
AC Adapter (included)
100-240 VAC wall plug type
AC adapter, galvanically isolated
adapter with 9Vdc output voltage.
Batteries (not included) 6 AA batteries,
1.5V alkaline
The expected use life of the pump is
500 hours.
To maintain your power adapter
follow these instructions:
Type BF applied part
Keep the device dry
Keep the device away from sunlight
Indicates the temperature limitation
for operation, transport and storage.
Indicates the humidity limitation for
operation, transport and storage.
Follow instructions for use
Identifies the manufacturer
Indicates the protection against
ingress of solid foreign objects and
against harmful effects due to the
ingress of water
Class II equipment
Do not dispose of electric/electronic
devices together with unsorted
municipal waste
SYMBOLS ON THE
PACKAGING
MEANING OF THE SYMBOLS
Transport/
Storage
20%
95%
Transport/
Storage
-4° F
+122° F
Operation
41° F
104° F
Operation
20%
80%
DO NOT use power adapter if damaged.
!
Warning: Children have STRANGLED in cords.
Keep the cords out of the reach of children.
DO NOT wrap cord of
power adapter around
the plug body.
CORRECT
DO NOT unplug
power adapter by
pulling on the cord.
CORRECT
TS EN 60601-1-2 STANDARD TEST REQUIREMENTS
Immunity Test Levels for ENCLOSURE PORT
Phenomenon
Basic EMC
standard or
test method
IMMUNITY TEST LEVELS
Professional healthcare
facility environment
HOME
HEALTHCARE
ENVIRONMENT
ELECTROSTATIC
DISCHARGE
IEC 61000-4-2
± 8 kV contact
± 2 kV, ± 4 kV, ± 8 kV, ± 15 kV air
Radiated RF EM fields
a)
IEC 61000-4-3
3 V/m
f)
80 MHz – 2,7 GHz
b)
80 % AM at 1 kHz
c)
10 V/m
f)
80 MHz – 2,7 GHz
b)
80 % AM at 1 kHz
c)
Proximity fields from RF
wireless communications
equipment
IEC 61000-4-3
See 8.10
RATED power frequency
magnetic fields
d) e)
IEC 61000-4-8
30 A/m
g)
50 Hz or 60 Hz