Lanner NCA-4112A User Manual Download Page 30

30 

 

TPM1: 2.54 Pin header 2x6 

 
 
 
 

 

 

 

LCM_1: 2.54 SMD Pin header 2x5 

 
 
 
 

 

 

 

LOM1: 2.54 SMD Pin header 2x6 

 
 
 
 

 

 

 

 

 

Pin 

Description 

Pin 

Description 

SERIRQ 

LFRAME 

LAD0 

CLK 

LAD1 

3VSB 

LAD2 

NC 

LAD3 

10 

3V3 

11 

RST 

12 

GND 

Pin 

Description 

Pin 

Description 

P5VSB 

P5V 

USB_D- 

NC 

USB_D+ 

HDD_LED 

GND 

GND 

COM2_TX 

10 

COM2_RX 

Pin 

Description 

Pin 

Description 

MDIP0 

MDIN0 

MDIP1 

MDIN1 

MDIP2 

MDIN2 

MDIP3 

MDIN3 

SPEED_100_N 

10 

ACT_N 

11 

SPEED_1G_N 

12 

P3VSB 

 

 

 

Summary of Contents for NCA-4112A

Page 1: ...1 NCA 4112 User Manual Version 1 0 Date of Release 2020 10 28 Network Appliance Platform...

Page 2: ...t utilizes different font types and icons in order to make selected text more transparent and explicable to users This document contains the following conventions Example Convention Usage iptables F M...

Page 3: ...pport department Copyright and Trademarks This document is copyrighted 2019 by Lanner Electronics Inc All rights are reserved The original manufacturer reserves the right to make improvements to the p...

Page 4: ...ft Corporation in the United States and or other countries All other product names or trademarks are properties of their respective owners Federal Communication Commission Interference Taiwan Corporat...

Page 5: ...ment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Any changes...

Page 6: ...quipement dangereux Coupez compl tement l alimentation en teignant l alimentation et en d branchant le cordon d alimentation avant d installer ou de retirer un ch ssis ou de travailler proximit de so...

Page 7: ...ittent failures Be sure to follow ESD prevention procedures when removing and replacing components to avoid these problems Wear an ESD preventive wrist strap ensuring that it makes good skin contact I...

Page 8: ...may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer...

Page 9: ...ffets n fastes du bruit externe et r duire les risques d lectrocution en cas de foudre Pour d sinstaller l quipement d branchez le c ble de mise la terre apr s avoir teint l appareil Un c ble de mise...

Page 10: ...Electrical Code and NFPA 75 Peut tre install dans des salles de mat riel de traitement de l information conform ment l article 645 du National Electrical Code et la NFPA 75 The machine can only be use...

Page 11: ...ront Panel 16 Rear Panel 17 Motherboard Information 18 Opening the Chassis 34 Installing the System Memory 36 Replacing the Cooling Fans 37 Mounting the System 38 Installing the AC Power Supply 39 Rem...

Page 12: ...12...

Page 13: ...1x LAN Cable Grey 1x SAS Cable Optional Accessories It is strongly recommended to use Lanner Slim type NIC modules on this system please consult Lanner for product compatibility if you consider adopt...

Page 14: ...P Intel 82599ES 1 PCIEx8 Fiber Bypass Non Latching Controller NCS2 IXM409A 4 10Gb SFP Intel XL710 BM1 1 PCIEx8 multi mode latch Form Factor 1U 19 Rackmount Platform Processor Options AMD EPYC 3000 Ser...

Page 15: ...ng Fans w Smart Fan Environmental Parameters Temperature 0 40 C Operating 20 70 C Non Operating Humidity RH 5 90 Operating 5 95 Non Operating System Dimensions WxDxH 438 x 431 x 44 mm Weight TBD Packa...

Page 16: ...ules F3 LED Indicators F4 Reset Button Press once for software reset Press twice for hardware reset F5 Console Port 1x RJ 45 Management Port F6 USB Ports or SFP Ports 2x USB 3 0 SKU B D 2x 10G SFP Por...

Page 17: ...to power off the system Long press 4sec to force the system to shut down Short press twice to have GPIO select NMI EVENT R3 Alarm off Button An audible alarm will sound when the system s redundant po...

Page 18: ...O RJ 45 Console Reset Bottom SATA3 0 4xDDR4 2667 Long DIMM support ECC R U DIMM 2x DIMM Channel 1xPCIE 8 or 2xPCIE 4 1x PCIEx4 LPC I350 One pair Gen3 bypass 2xSFP M 2 MiniPCIE 1xPCIE 8 or 2xPCIE 4 One...

Page 19: ...nated pins push the jumper down on them so that they become SHORT To make the pins setting OPEN simply remove the jumper cap 2 pin Header 3 pin Header 4 pin Header Open Short Open 1 2 Jumped Open 1 2...

Page 20: ...ND 10 GND 11 5V 12 GND 13 GND 12 GND 15 PROK 16 NC 17 5VSB 18 5V 19 12V 20 5V 21 12V 22 5V 23 3 3V 24 GND ATX2 Power Supply Connector CON2 3 SATA Power Connector 1x4 Pins 2 54mm PIN NO DESCRIPTION PIN...

Page 21: ...A CONNECTOR PIN NO DESCRIPTION 1 GND 2 TX 3 TX 4 GND 5 RX 6 RX 7 GND PIN NO DESCRIPTION PIN NO DESCRIPTION 1 USB5V 10 USB5V 2 D1 11 D2 3 D1 12 D2 4 GND 13 GND 5 SSRX1 14 SSRX2 6 SSRX1 15 SSRX2 7 GND 1...

Page 22: ...C_UIM_PWR 34 GND 9 GND 35 GND 10 NC_UIM_DATA 36 USB_D 11 REFCLK 37 GND 12 NC_UIM_CLK 38 USB_D 13 REFCLK 39 VCC3 14 NC_UIM_RST 40 GND 15 GND 41 VCC3 16 NC_UIM_VPP 42 NC_LED_WWAN 17 NC_RSV3 43 GND 18 GN...

Page 23: ...23...

Page 24: ...ND 21 GND PCIE_RX_P6 22 GND PCIE_RX_N6 23 PCIE_TX_P5 GND 24 PCIE_TX_N5 GND 25 GND PCIE_RX_P5 26 GND PCIE_RX_N5 27 PCIE_TX_P4 GND 28 PCIE_TX_N4 GND 29 GND PCIE_RX_P4 30 CLK_1_DP PCIE_RX_N4 31 CLK_1_DN...

Page 25: ..._1_DN 15 PCIE_TX_N8 GND 16 GND PCIE_RX_P8 17 NC PCIE_RX_N8 18 GND GND 19 PCIE_TX_P9 NC 20 PCIE_TX_N9 GND 21 GND PCIE_RX_P9 22 GND PCIE_RX_N9 23 NC GND 24 NC GND 25 GND NC 26 GND NC 27 NC GND 28 NC GND...

Page 26: ...AIR2_RXP 20 NC 21 GND 22 NC 23 PAIR2_TXN 24 NC 25 PAIR2_TXP 26 NC 27 GND 28 NC 29 PAIR1_RXN 30 NC 31 PAIR1_RXP 32 NC 33 GND 34 NC 35 PAIR1_TXN 36 NC 37 PAIR1_TXP 38 NC 39 GND 40 NC 41 PAIR0_RXP 42 NC...

Page 27: ...iption 1 5V 2 GND 3 SLIN 4 VEE 5 AFD 6 INIT 7 PD1 8 PD0 9 PD3 10 PD2 11 PD5 12 PD4 13 PD7 14 PD6 15 LCD_N 16 5V 17 KPA1 18 KPA2 19 KPA3 20 KPA4 21 RST 22 CRT_GRN 23 CTR_YLW 24 HD_LED Pin Description P...

Page 28: ...5Pin FAN connector 9 D1 19 V5USB 10 LTE_PWR 20 KEY PIN DESCRIPTION PIN DESCRIPTION 1 GPO_1 2 GPI_1 3 GPO_2 4 GPI_2 5 GPO_3 6 GPI_3 7 GPO_4 8 GPI_4 9 GND 10 GND Pin No Description 1 GND 2 12V 3 FANIN1...

Page 29: ...Detect DCDA 2 Data Set Ready DSRA 3 Receive Data RXDA 4 Request To Send RTSA 5 Transmit Data TXDA 6 Clear To Send CTSA 7 Data Terminal Ready DTRA 8 Ring Indicator RIA 9 Ground GND 10 Key pin JPWR1 Pow...

Page 30: ...2 LFRAME 3 LAD0 4 CLK 5 LAD1 6 3VSB 7 LAD2 8 NC 9 LAD3 10 3V3 11 RST 12 GND Pin Description Pin Description 1 P5VSB 2 P5V 3 USB_D 4 NC 5 USB_D 6 HDD_LED 7 GND 8 GND 9 COM2_TX 10 COM2_RX Pin Descriptio...

Page 31: ...K 2 LAD1 3 RST 4 LAD0 5 LRAME 6 P3V3 7 LAD3 8 KEY 9 LAD2 10 GND Pin Description Pin Description 1 CRT_RED 2 GND 3 CRT_GREEN 4 GND 5 CRT_BLUE 6 GND 7 CRT_HSYNC 8 NC 9 CRT_VSYNC 10 GND 11 DDC_DATA 12 DD...

Page 32: ...SCRIPTION PIN DESCRIPTION 1 P3V3 2 SGPIO_SMBUS_CLK 3 NC 4 SGPIO_SMBUS_DATA 5 AGPIO 6 6 SGPIO0_CLK 7 EGPIO 119 8 SGPIO0_DATAOUT 9 GND 10 SGPIO0_LOAD PIN DESCRIPTION PIN DESCRIPTION 1 P1V8SB 2 HDT_TCK 3...

Page 33: ...eader 1x4 Power PWM controller programming Pin Description W O Jumper default Normal W Jumper Disable RTC power Pin Description 1 P0_SPD_SMBUS_CLK 2 P0_HP_SMBUS_CLK 3 SFPP_SMBUS_CLK 4 P0_BMC_SCL Pin D...

Page 34: ...ompletely Also please wear ESD protection gloves when conducting the steps in this chapter Opening the Chassis 1 Loosen the 2 thumb screws from the rear panel 2 Gently pull the cover backward a bit an...

Page 35: ...stem supports multiple wireless connectivity methods with two M 2 slots and a MPCIE slot Based on your application and modules used install modules in the corresponding slots IPMI Card NIC 1x PCIE x8...

Page 36: ...imum DIMM Installed Each processor requires at least 2 memory modules to boot and run from Memory Module Installation Instructions Please follow the steps below to install the DIMM memory modules 1 Po...

Page 37: ...ust reverse the steps to install the fan back onto the enclosure and the system 1 Remove the chassis cover 2 From the rear side of the fan loosen the screw that secures the fan connector 3 Disconnect...

Page 38: ...cket assembly alone cannot provide sufficient support to the chassis Please ensure the use of these brackets goes with a shelf or slide rails to prevent the chassis from falling over Slide Rail Kit Sh...

Page 39: ...entually Please be noted that this system supports only 300W PSU Please prepare the power supply units matching this capacity 1 On the rear panel locate the power supply units and disconnect the power...

Page 40: ...pport KCS System Interface Support LAN RMCP IPMI 2 0 based Management BMC stack with an IPMI 2 0 implementation System Management Sensor monitoring System power management Watchdog timer Fan speed mon...

Page 41: ...t Chassis power soft Server s power status report Watchdog Timer The BMC provides an IPMI 2 0 compatible watchdog timer which can prevent the system from system hanging Fan Speed Control BMC is in cha...

Page 42: ...Moreover the account creator is allowed to enable disable the user account at any time If not specified the default user accounts are listed follows User Name Password User Access Characteristics adm...

Page 43: ...sis Status Chassis 00h 01h Chassis Control Chassis 00h 02h Chassis Reset Chassis 00h 03h Sensor Device Commands Get Sensor Reading Factors S E 04h 23h Get Sensor Hysteresis S E 04h 25h Get Sensor Thre...

Page 44: ...Device Commands Set LAN Configuration Parameters Transport 0Ch 01h Get LAN Configuration Parameters Transport 0Ch 02h Serial Modem Device Commands Set User Callback Options Transport 0Ch 1Ah Get User...

Page 45: ...r username and password A screenshot of the login screen is given below Login Page Username Enter your username in this field Password Enter your password in this field Sign me in After entering the r...

Page 46: ...hange the default password Dialog Clicking OK will take you to the User Management Configuration page to set a password Change the default password Set password Note Duplicate usernames shouldn t exis...

Page 47: ...Menu Bar The menu bar displays the following Dashboard Sensor Event Log Settings Remote Control Image Redirection Power Control Maintenance Sign out A screenshot of the menu bar is shown below Menu B...

Page 48: ...fication Click the icon to view the notification messages Refresh Click the icon to reload the current page Sign out Click the icon to log out of the Web UI This option shows the logged in username an...

Page 49: ...e and make a bootable DVD from it 2 Connect a DVD player or other type of readers floppy disk or a drive to a computer 3 Connect to your target system from this computer Refer to Remote Server Managem...

Page 50: ...ewer screen pops up select Media and then Virtual Media Wizard from the toolbar 6 On Virtual Media screen select your media type to load the image For example click on Browse of CD DVD Media 1 and the...

Page 51: ...atus window will display the connection status 8 The installation process will automatically start Please follow the onscreen instruction to complete the rest of the steps and restart the target syste...

Page 52: ...ystem 2 Pressing the Tab or Del key immediately allows you to enter the Setup utility and then you will be directed to the BIOS main screen The instructions for BIOS navigations are as below Control K...

Page 53: ...on CRB code base X64 Compliancy UEFI version PI version Project Version BIOS release version Build Date and Time MM DD YYYY Access Level Administrator User System Date To set the Date use Tab to switc...

Page 54: ...54 Select the Advanced menu item from the BIOS setup screen to enter the Advanced setup screen Users can select any of the items in the left frame of the screen...

Page 55: ...55 AMD CBS Feature Options Description Ac Loss Control Always Off Always On Previous Select Ac Loss Control Method...

Page 56: ...tions Description Security Device Support Enabled Disabled Enables or disables BIOS support for security device By disabling this function OS will not show Security Device TCG EFI protocol and INT1A i...

Page 57: ...curity Device NOTE Your computer will reboot during restart in order to change State of the Device Pending operation None TPM Clear Schedules an Operation for the Security Device NOTE Your computer wi...

Page 58: ...58 Trusted Computing TPM2 0...

Page 59: ...erarchy Storage Hierarchy Enabled Disabled Enables or disables Storage Hierarchy Endorsement Hierarchy Enabled Disabled Enables or disables Endorsement Hierarchy TPM2 0 UEFI Spec Version TCG_1_2 TCG_2...

Page 60: ...60 Super IO Configuration...

Page 61: ...61 Serial port 1 Configuration Feature Options Description Serial Port Enabled Disabled Enables or disables Serial Port COM Device Settings NA IO 3F8h IRQ 4...

Page 62: ...62 Serial port 2 Configuration Feature Options Description Serial Port Enabled Disabled Enables or disables Serial Port COM Device Settings NA IO 2F8h IRQ 3...

Page 63: ...63 H W Monitor...

Page 64: ...get Temperature T2 Input Target Temperatur Range 0 127 Target Temperature T3 Input Target Temperatur Range 0 127 Target Temperature T4 Input Target Temperatur Range 0 127 Critical Temperature Input Ta...

Page 65: ...65 Serial Port Console Redirection Feature Options Description COM0 Console Redirection Enabled Disabled Enables or disables Console Redirection...

Page 66: ...Extended ASCII char set Bits per second 9600 19200 38400 57600 115200 Selects serial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds D...

Page 67: ...pport for ANSI VT100 terminals Recorder Mode Disabled Enabled With this mode enabled only text will be sent This is to capture Terminal data Resolution 100x31 Disabled Enabled Enables or disables exte...

Page 68: ...lution 80x24 80x25 On Legacy OS the Number of Rows and Columns supported redirection Redirection After BIOS POST Always Enable BootLoader When Bootloader is selected Legacy Console Redirection is disa...

Page 69: ...CPU Configuration Feature Options Description SVM Mode Enabled Disabled Enable disable CPU Virtualization SMEE Enabled Disabled Control secure memory encryption enable...

Page 70: ...led Globally Enables or Disables 64bit capable Devices to be Decoded in Above 4G Address Space Only if System Supports 64 bit PCI Decoding SR IOV Support Enabled Disabled If system has SR IOV capable...

Page 71: ...ff support The XHCI ownership change should be claimed by XHCI driver USB Mass Storage Driver Support Enabled Disabled Enables or disables USB Mass Storage Driver Support Port 60 64 Emulation Enabled...

Page 72: ...wer up delay Auto Manual Maximum time the device will take before it properly reports itself to the Host Controller Auto uses default value for a Root port it is 100 ms for a Hub port the delay is tak...

Page 73: ...Network Stack Configuration Feature Options Description Network Stack Disabled Enabled Enables or disables UEFI Network Stack...

Page 74: ...ls the execution of UEFI and Legacy PXE OpROM Storage Do Not Launch UEFI Legacy Controls the execution of UEFI and Legacy Storage OpROM Video Do Not Launch UEFI Legacy Controls the execution of UEFI a...

Page 75: ...NVME Configuration...

Page 76: ...Control Legacy PXE Boot Feature Options Description Control Legacy PXE Boot from t Disabled MGT LAN1 Control Legacy PXE Boot from which Lan...

Page 77: ...the screen Feature Description Administrator Password If ONLY the Administrator s password is set it only limits access to Setup and is only asked for when entering Setup User Password If ONLY the Us...

Page 78: ...is activated when Platform Key PK is enrolled System mode is User Deployed and CSM function is disabled Secure Boot Mode Standard Custom Customizable Secure Boot mode In Custom mode Secure Boot Polic...

Page 79: ...vision factory default Secure Boot keys when System is in Setup Mode Install Factory Default keys None Force System to User Mode install all Factory Default keys Enroll Efi Image None Allow the image...

Page 80: ...The number of seconds to wait for setup activation key 65535 means indefinite waiting Bootup NumLock State On Off Select the keyboard NumLock state Quiet Boot Disabled Enabled Enables or disables Qui...

Page 81: ...ation The following window will appear after the Discard Changes and Exit option is selected Select Yes to Discard changes and Exit Setup Save Changes and Reset When Users have completed the system co...

Page 82: ...estore Defaults Restore default values for all setup options Select Yes to load Optimized defaults Note The items under Boot Override were not same with image It should depend on devices connect on sy...

Page 83: ...mber Link has been established and there is activity on this port Solid Amber Link has been established and there is no activity on this port Off No link is established Speed Solid Amber Operating as...

Page 84: ...The following conditions are excluded from this warranty Improper or inadequate maintenance by the customer Unauthorized modification misuse or reversed engineering of the product Operation outside of...

Page 85: ...85 RMA Service Request Form When requesting RMA service please fill out the following form Without this form enclosed your RMA cannot be processed...

Reviews: