Lanner FW-8756 User Manual Download Page 4

1

Introduction

Chapter 1

Network Application Platforms

Chapter 1:   

Introduction

Thank  you  for  choosing  the  FW-8756. The  FW-8756  is  a 

1U  network  communication  appliance  that  is  designed 

to  meet  your  demand  for  quality  network  application 

platform. 
The FW-8756 supports different class of  Intel 90 nm CPUs 

packaged  in  LGA  775    for  user  selection  including  Intel 

Core2 Quad, Intel Core 2 Duo, and Intel Celeron.
The  FW-8756  comes  with  1  FE  and  6  Gb  Ethernet  ports 

with  three  pair  capable  to  be  an  abnormal  state  packet 

dual  latch  bypass  (the  newest  Generation  3  bypass).  In 

addition, with the Lanner riser card, an optional expansion 

LAN module can be added.
Here  is  the  list  of  some  key  features  of  the  FW-8756 

system:

Built on Intel chipset G41 and ICH7R

• 

Two COM ports: 1 x RJ45 Serial Console port (CISCO 

• 

TYPE) and 1 pin header on board (2x5)
Two USB 2.0 Ports on the front panel and one USB2.0 

• 

pinheader (2x5)
one 3.5”SATA II HDD or  two 2.5”SATA II

• 

One VGA pin header (Sku A only)

• 

One  IPMI  management  port  through  the  OPMA 

• 

connector (SKu B only)
One PCI-Ex8 for expansion riser card

• 

3 pairs of the Generation 3 bypass ports

• 

Please  refer  to  the  chart  below  for  a  summary  of  the 

system’s specifications. 

System Specification

Feature

  

Description

Form Factor

1U Rackmount

Platform

Processor

Supports Intel Core2 Quad, 
Core2 Duo, PentiumD, Celeron 
Processors, LGA775

Chipset

Intel G41 + ICH7R

Embedded  Accelerator

by request

System Memory

Technology

DDR3 800/1066/1333 MHz

Max Capacity

4GB

Socket

2 x 240P DIMM

OS Support

Windows, Linux

Storage

HDD Bay(s)

1 x 3.5” or 2 x 2.5”

Storage Interface

2 x Serial ATA, 
1 x CompactFlash

Networking

Ethernet Port Density

6 x RJ45 GbE Onboard
1 x RJ45 FE
1 x Optional Module

Controller

6 x Intel 82574L
1 x Intel FE LAN

Network Module(s)

1 x Tray to fit Lanner 8800 
Series Modules

Bypass

3 x pairs of LAN bypass

I/O Interface

Console

1 x RJ45

USB

2 x USB 2.0

IPMI via OPMA slot

Optional

Expansion

PCI

1 x Mini-PCI

Cooling

Processor

1U Passive heatsink with 3 
cooling fans

System

1 x Cooling Fan with Smart Fan

Environmental

Parameters

Temperature, ambient 
operating / storage

0ºC~40ºC / -20ºC~60ºC

Humidity (RH), ambient 
operating and non-
operating

5 ~ 95%, non condensing

Miscellaneous

LCD Module

2 x 20 Character
Optional Graphic LCM

Watchdog

Yes

Internal RTC with Li 
Battery

Yes

Physical 

Dimensions

Dimensions (WxHxD)

431 x 44.4 x 395 mm

Weight

6 kg (13.2 lbs)

Power

Type / Watts

1U ATX /200W

Input

AC 90~264V@47~63Hz

Output

+5V output: 1V min, 12V max; 
+3.3V output: 1V min, 14V 
max; 
+12V output 1V min, 14V max

Approvals &

Compliance

CE Emission, FCC Class A, 
RoHS

Summary of Contents for FW-8756

Page 1: ...Network Application Platforms Hardware platforms for next generation networking infrastructure FW 8756 User s Manual Publication date 2011 03 23...

Page 2: ...inal manufacturer assumes no responsibility for its use nor for any infringements upon the rights of third parties that may result from such use Acknowledgement Intel Pentium and Celeron are registere...

Page 3: ...Riser Card Installation 7 Front Ethernet Module Installation 7 Chapter 3 Motherboard Information 8 Block Diagram 8 Motherboard Layout 9 Jumper Settings 10 Appendix A ProgrammingWatchdogTimer 13 Appen...

Page 4: ...fications System Specification Feature Description Form Factor 1U Rackmount Platform Processor Supports Intel Core2 Quad Core2 Duo PentiumD Celeron Processors LGA775 Chipset Intel G41 ICH7R Embedded A...

Page 5: ...Ethernet cable 1 8 meters 1 straight through Ethernet cable 1 8 meters 1 RJ 45 to DB 9 female console cable Cisco type CPU heat sink 1 threaded screw set 1 short ear bracket set Front name plate labe...

Page 6: ...s to any USB devices for example a flash drive F6 Management Port ThisFastEthernetportcanbeconnectedforconfigurationortroubleshootingpurpose AconformitywithIPMI Intelligent PlatformManagementInterface...

Page 7: ...Platforms R1 System Fan CPU Fans 1 2 3 R2 Power on Switch It is a switch to turn on or off the power R3 AC Power in socket It is a 200W ATX power supply unit with input range of 90 264V 47 63Hz R4 Pow...

Page 8: ...odules DIMM sockets Open the DIMM slot latches 1 Install the DIMM 2 Note All DIMMs installed must be the same speed 1 DDR3 800 1066 or 1333 Do not install DIMMs supporting different speeds Installing...

Page 9: ...2 tab Lift the load lever and then the plate 3 Align the cut out of the CPU and the notch on the 4 socket The CPU should fit perfectly into the socket Note that the CPU fits in the socket in only one...

Page 10: ...rnet module take off the front 1 bezel first by unfastening the threaded screws at the bottom of the case Insert the Ethernet module into the front expansion 2 slot Youshouldhearaclickwhenthemodulecon...

Page 11: ...Application Platforms Chapter 3 Motherboard Information Block Diagram The block diagram depicts the relationships among the interfaces or modules on the motherboard Please refer to the following figu...

Page 12: ...VGA Cable Connector Clear CMOS Reset Switch Keyboard and Mouse Connectors PCI Ex8 golden finger Mini PCI Connector Fan3 Fan 2 Fan 1 Fan 4 Connectors DIMM Socket Fan5 Connector Serial Cable Connector...

Page 13: ...on when inserting the plugs for the supply plugs are designed to fit these connectors in only one orientation VGA Interface J1 It is for connecting the VGA interface cable Keyboard and mouse interface...

Page 14: ...Pin No Description Pin No Description 1 TIP 2 RING 3 8PMJ 3 4 8PMJ 1 5 8PMJ 6 6 8PMJ 2 7 8PMJ 7 8 8PMJ 4 9 8PMJ 8 10 8PMJ 5 11 LED1_GRNP 12 LED2_YELP 13 LED1_GRNN 14 LED2_YELP 15 CHSGND 16 RESERVED 1...

Page 15: ...umper J13 when an AT mode power switch is used AT ATX Mode Selection Jumper J24 Please adjust the jumpers J24 and J13 respectively as described in the flollowing jumper settings when conneting the pow...

Page 16: ...king a watchdog timer is based on a counter that counts down from an initial value to zero The software selects the counter s initial value and periodically restarts it Should the counter reach zero b...

Page 17: ...console cable to console port 1 of the system and the other end to serial port of the Remote Client System Configure the following settings in the BIOS Setup 2 menu for FW 8756 BIOS Advanced Remote A...

Page 18: ...orted by Lanner LCM function include platforms based on Linux Kernel series 2 4 x and Linux Kernel series 2 6 x Install insmod plcm_drv ko mknod dev plcm_drv c 241 0 Note If you cannot install the dri...

Page 19: ...the following features Communication through SMBUS I2C Independent bypass status control for each pair up to a total of 4 pairs Lanner Bypass Modules can bypass systems Ethernet ports on a host syste...

Page 20: ..._module WINXP folder Then Double click the PROXP EXE The 4 DriverInstaller InstallShield Wizard starts off by extracting files The Intel Network Connections InstallShield Wizard will appear as shown i...

Page 21: ...example the file name of driver version 7 0 38 is e100 or1000 7 0 38 tar gz Untar unzip the archive where x x x is the version 3 number for the driver tar file tar zxf e1000 x x x tar gz Change to the...

Page 22: ...vileges Insert the Drivers and user s manual CD to the optical 2 drive Browse the contents of the support CD to locate the 3 file executable program from the Driver Vga_driver Then Double click the ex...

Page 23: ...ll be returned at customer s expense The following conditions are excluded from this 5 warranty Improper or inadequate maintenance by the customer Unauthorized modification misuse or reversed engineer...

Page 24: ...ing by Air Freight Sea Express ___ Others ________________ Item Model Name Serial Number Configuration Item Problem Code Failure Status Problem Code 01 D O A 02 Second Time R M A 03 CMOS Data Lost 04...

Reviews: