Item

Name of article

Type

Qty.

01

Preamplifier 10 MHz to 10 GHz

PA 3010

1

02

Power supply unit

NT FRI EU or NT FRI US

1

03

System case

Case A5

1

04

Quick guide

1

05

User manual

1

The scope of delivery may deviate depending on the respective order.

Figure 1 - System case of PA 3010 set

3 Scope of Delivery

Summary of Contents for PA 3010 set

Page 1: ...User Manual Translation of the original PA 3010 set Preamplifier 10 MHz up to 10 GHz Copyright August 2021 LANGER EMV Technik GmbH 2021 09 24 PA 3010 Bedienungsanleitung A5_DE_ENG_PS...

Page 2: ...of Liability 4 2 4 Errors and Omissions 4 2 5 Copyright 4 3 Scope of Delivery 5 4 Technical Parameters 6 4 1 Connections and Dimensions 6 4 2 Measurements and Characteristics 7 5 Safety 9 5 1 Intende...

Page 3: ...0 EU Restriction of certain Hazardous Substances 2011 65 EU EU 2015 863 For the implementation of the requirements from the above mentioned directives the following applicable standards were used DIN...

Page 4: ...assume no liability for personal injury or damage to material if the instructions in this user manual were not followed the PA 3010 set was operated by staff not qualified in the field of EMC and who...

Page 5: ...ier 10 MHz to 10 GHz PA 3010 1 02 Power supply unit NT FRI EU or NT FRI US 1 03 System case Case A5 1 04 Quick guide 1 05 User manual 1 The scope of delivery may deviate depending on the respective or...

Page 6: ...mption 170 mA Max input power destruction threshold 17 dBm Max DC component at RF input output 9 V Amplitude flatness 3 dB Housing dimensions height x width x depth 50 x 38 x 14 mm Weight 60 g Connect...

Page 7: ...compression point 0 01 29 3 6 3 8 2 2 8 4 0 1 30 16 1 4 18 1 3 4 0 1 30 15 1 4 20 1 2 3 1 19 2 29 13 1 6 12 1 7 2 7 17 3 30 17 1 3 13 1 6 2 1 18 4 30 13 1 6 11 1 8 2 1 18 5 30 9 2 2 10 1 9 2 2 18 6 31...

Page 8: ...PA 3010 set 8 12 Figure 4 PA 3010 1 dB compression point Figure 5 PA 3010 noise figure...

Page 9: ...rameters The field of application is changed by modifications to the design Claims due to the improper use of the PA 3010 set are excluded 5 3 Staff Requirements Only persons who are trained and quali...

Page 10: ...ey are connected to the preamplifier due to its funtion the input of the PA 3010 preamplifier is not secured against ESD For this we recommend to establish a low impedance connection between the inner...

Page 11: ...e with the WEEE Directive 2012 19 EU Waste of Electrical and Electronic Equipment the following must be observed At the end of its service life this product should be taken to a suitable disposal faci...

Page 12: ...e statutory warranty period either by repair or by delivery of spare parts This warranty is only granted on condition that the information and instructions in the user manual have been observed The wa...

Reviews: