background image

2

 

 

 

These symbols are intended to alert the user to the presence of 
important operating and maintenance instructions in the manual 
accompanying the appliance.

RETAIN THIS MANUAL FOR FUTURE REFERENCE

NOTICE

Using any part other than genuine Star factory supplied parts relieves the 
manufacturer of all liability.

Star reserves the right to change specifi cations and product design without 
notice.  Such revisions do not entitle the buyer to corresponding changes, 
improvements, additions or replacements for previously purchased 
equipment.

Due to periodic changes in designs, methods, procedures, policies and 
regulations, the specifi cations contained in this sheet are subject  to change 
without notice.  While Star Manufacturing exercises good faith efforts to provide 
information that is accurate, we are not responsible for errors or omissions 
in information provided or conclusions reached as a result of using the 
specifi cations.  By using the information provided, the user assumes all risks in 
connection with such use.

MAINTENANCE AND REPAIRS

Contact your local authorized service agent for service or required maintenance.  Please record the model 
number, serial number, voltage and purchase date in the area below and have it ready when you call to 
ensure faster service. 

 

SAFETY SYMBOL

Model No.

Serial No.

Voltage

Purchase Date

Business  

8:00 am to 4:30 p.m. Central Standard Time

Hours:

 

Telephone:

 

(800) 807-9054   Local (314) 781-2777

Fax: 

 

(800) 396-2677   Local (314) 781-2714

E-mail

  

[email protected]

                  

[email protected]

                 

[email protected]

Website:

        

www.star-mfg.com     

   

The Star Service Help Desk

Authorized Service Agent 

Reference the listing provided with the unit

 or

for an updated listing go to:

Website:

        

www.star-mfg.com    

E-mail

  

[email protected]

Telephone:

 

(800) 807-9054   Local (314) 781-2777

Mailing Address:

    Star Manufacturing International Inc.

  10 

Sunnen 

Drive

  St. 

Louis, 

MO 

63143 

  U.S.A 

 

Summary of Contents for R30S-M

Page 1: ...International 10 Sunnen Drive St Louis MO 63143 3800 Part Number 2M W1090 Ph 314 781 2777 Fax 314 781 2714 Rev B WWW STAR MFG COM March 7 2008 Installation Operation Maintenance Instructions Electric...

Page 2: ...information provided or conclusions reached as a result of using the speci cations By using the information provided the user assumes all risks in connection with such use MAINTENANCE AND REPAIRS Con...

Page 3: ...control these units All thermostats are used in conjunction with a red indicator or pilot lamp When the light is on the elements are energized and bringing the plate to the temperature set on the ther...

Page 4: ...range oven is also provided with an adjustable automatic temperature control the dial which is located in the range switch panel The setting of the control dial establishes the average temperature to...

Page 5: ...nded Light duty saucepans and small stock pots Not Recommended Heavy stock pots or heavy urns or kettles 12 x 24 or 24 x 24 Griddle plates controlled by thermostats Temperature range 450o F Recommende...

Page 6: ...ce After each cooking load scrape the griddle surface to remove any carbonized grease CAUTION When scraping griddle surface do not scrape the splash guard It may eventually be cut through Weekly Clean...

Page 7: ...E OVEN ARE SHOWN AT LEFT CONNECTED TO THEIR RESPECTIVE CIRCUIT BREAKERS 3 SEE SERVICE CONNECTION CHART FOR PROPER CONNECTION OF CIRCUIT BREAKERS TO POWER SUPPLY 2 1 3 4 P1 P2 2 1 3 4 P1 P2 1 2 4 3 1 2...

Page 8: ...ECTION AND THE OVEN ARE SHOWN AT LEFT CONNECTED TO THEIR RESPECTIVE CIRCUIT BREAKERS 3 SEE SERVICE CONNECTION CHART FOR PROPER CONNECTION OF CIRCUIT BREAKERS TO POWER SUPPLY 2 1 3 4 P1 P2 2 1 3 4 P1 P...

Page 9: ...RS N L1 L2 L3 SECTION 2 C TOP ARRANGEMENT SECTION 1 C C C B B B B A 18 A 30 PREVIOUS MODEL DESIGNATION 32S 1 32S 2 32S 2M H 32S 2M G 32S 4 32S 4M 32S 3M G 32S 3 32S 3M H R30S ATA R30S ATB R30S ATD R30...

Page 10: ...VIOUS MODEL DESIGNATION 32S 1 32S 2 32S 2M H 32S 2M G 32S 4 32S 4M 32S 3M G 32S 3 32S 3M H R30S ATA R30S ATB R30S ATD R30S ATE R30S ATC R30S ATF STAR MODEL DESIGNATION A 18 EXAMPLE FOR DETERMINING THE...

Page 11: ......

Page 12: ...SK2355 Rev 3 6 07 Model R30S Marine Range Top Assy 1 2 3 7 3 8 9 10 14 16 17 18 11 12 6 4 5 Old Style See Control Panel Detail 4 5 18 Suggested Parts Stocking...

Page 13: ...W ATB 240V ATD 240V 2N 11120 13 4 ELMNT TK 240V 2600W ATA 240V 2N 11120 14 2 ELMNT TK 480V 2600W ATB 440 480V 2N 11120 14 4 ELMNT TK 480V 2600W ATA 440 480V 2N 11120 18 4 ELMNT TK 380V 2000W ATA 380V...

Page 14: ...SK2356 Rev 3 6 07 Model R30S Marine Range Oven Assy 1 3 4 6 7 10 9 8 12 15 15 24 22 23 15 15 13 13 14 14 16 17 18 19 20 21 11 5 2 Suggested Parts Stocking 11 13 14 22 7 8 9 10 4...

Page 15: ...G LABEL ALL 7 2J 31601 01 1 PILOT LT 250V 6LEAD BLK 208 240V 7 2J 31601 02 1 PILOT LT 480V 6LEAD BLK 380V 440V 480V 8 2T 30402 08 1 STAT ADJ 450o 72 C T ALL 9 2E 30304 35 2 SWTROT3HT 240 480VAC20AMP A...

Page 16: ...20109 04 6 SCREW THD MS SS 10 32X 3 8 A C B Part No Qty Description 50302 302 1 SEARAILASSY 2 RT30 32 SK A 50302 307 1 SEARAIL LH SIDE RT30 B 50302 308 1 SEARAIL RH SIDE RT30 C 50302 317 6 SEARAIL SI...

Page 17: ...9 R30S ATB 1 2 4 10 8 9 16 16 8 13 14 13 7 6 R30S ATC 2 4 8 15 16 8 10 10 12 14 13 7 6 R30S ATD 2 4 16 16 8 11 14 15 9 13 13 7 6 SK2357 Rev 3 7 08 Model R30S Marine Range Top Controls 10 6 11 13 14 Su...

Page 18: ...R30S ATE 2 4 3 7 8 8 12 15 15 11 10 14 16 13 14 16 13 6 R30S ATF 3 4 7 12 13 14 16 16 8 15 8 11 15 14 6 10 6 11 13 14 Suggested Parts Stocking SK2358 Rev 3 7 08 Model R30S Marine Range Top Controls...

Page 19: ...23 1 STAT ADJ 850o 48C T NAK ATB ATE 2T 30402 23 2 STAT ADJ 850o 48C T NAK ATC 11 2T 30402 08 1 STAT ADJ 450o 72 C T ATD ATE 2T 30402 08 2 STAT ADJ 450o 72 C T ATF 12 P9 CR30 311 1 CONTROL FRONT SS A...

Page 20: ...STAR MANUFACTURING 10 Sunnen Drive St Louis MO 63143 U S A 800 807 9054 314 781 2777 Parts Service 800 807 9054 www star mfg com...

Reviews: