background image

SEASONING THE COOKING SURFACES

The cooking surfaces must be "seasoned" in order to reduce product sticking .  To season, bring grill 
to 300°F, until completed .  Brush upper and lower cooking surfaces with a a salt free liquid vegitable 

oil.  If using an aerosol agent, first apply into a cup and then brush onto cooking surface.  Let sit for 20 

minutes, and then wipe clean using a warm damp cloth .  Repeat if required .

SETTING THE TEMPERATURE

The thermostat control knob is used to set the temperature to your requirements .  The maximum set 
point is 450°F (232°C), the minimum set point is 175°F (79°C) .

DAILY OPERATION

Check the power cord to insure that it is plugged into a proper outlet .

Check that the thermostat control is turned on .   
The pilot light will come on when the thermostat control goes past the 175°F .

Set the thermostat control knob to desired temperature .

Always allow 20 minutes of preheat time before loading the unit with product .   

Failure to allow sufficient preheat time will result in unsatisfactory cooking of the first load.

OPERATING HINTS AND SAFETY

Disconnect power to the unit with the switch at the end of each day of operation .

Do not leave the unit in operation without an attendant .

Turn thermostat down to 200°F (93°C) during idle periods .  It will take only a few minutes to regain 
operating temperature .

Use spatula to push excess grease into grease cup after each load of food is cooked .   
This will reduce smoking of hot grease and carbonizing .

Do not leave the unit at high temperature when not in use or during idle periods .   

This will cause food particles and grease film to carbonize.

"Season" cooking surfaces with non-salted vegetable oil to reduce product sticking .

MONTHLY LUBRICATION/INSPECTION

Apply two (2) drops of non-toxic mineral or vegetable oil to hinge bracket at the rear .

Check the bolts, screws and nuts, tighten if necessary .

TOP HOUSING MAINTENANCE

The Spring setting which holds the top housing in the up 
position is set at the factory and should provide many years 
of use without the need of adjusting .  After a extended period 
of time the top housing may not maintain its original setting, 
therefore the spring tension can be adjusted by tightening and 
loosening the Retainer bolts on the back of the unit .

Abobe: Oiling the Hinge,  

Below: Tightening the top housing

Summary of Contents for PaneBella Fresco PBF12G

Page 1: ...TWO SIDED GRILLS MODEL PBF12G PBF12S PBF14G PBF14S PBF24G PBF24S PBF24SG Installation and Operation Instructions 2M W1448 Rev A 12 15 10 PBF12G...

Page 2: ...ERVICE PERSONNEL ONLY NOTICE Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all liability Star reserves the right to change speci cations and product design...

Page 3: ...Maintenance Cleaning 7 Troubleshooting 7 Wiring Diagram PBF12 PBF14 208 240VAC 8 PBF24 240V 9 Exploded View Parts List 10 13 PROBLEMS QUESTIONS or CONCERNS Before you proceed consult you authorized L...

Page 4: ...h carrier within 15 days Be certain to retain all contents plus external and internal packaging materials for inspection The carrier will make an inspection and will supply necessary claim forms VENTI...

Page 5: ...y debris from the grilling surface WARNING Model Height D x Width A x Depth B Clearance from combustible surface Weight Freight Class Actual Shipping PBF12 G S 21 8 x 15 75 x 19 9 Sides 0 Back 0 45 lb...

Page 6: ...AND SAFETY Disconnect power to the unit with the switch at the end of each day of operation Do not leave the unit in operation without an attendant Turn thermostat down to 200 F 93 C during idle peri...

Page 7: ...you must re season the grill See Seasoning Grill 2 Acidic cleaners are NOT recommended as a cleaning agent DO NOT IMMERSE OR LET THE UNIT STAND IN WATER DO NOT HOSE DOWN THE UNIT OR THE TABLE COUNTER...

Page 8: ...6 15P ON 240V 1 800 WATT UNITS 20 AMP PLUG NEMA 6 20P ON 240V 3 600 WATT UNITS IEC 320 POWER INLET 16 AMP RATING SEE SEPERATE SKETCH 230V UNITS TOP ELEMENT 1 BLACK 3 3 2 1 TERMINAL BLOCK BOTTOM ELEMEN...

Page 9: ...OM PLATE REMOVED ITEMS ARE IN GENERAL LOCATION BUT MAY BE RELOCATED OR SCALED FOR CLARITY G 20 N 19 18 L TOP ELEMENT 3 2 3 1 1 11 12 11 12 CERTAIN INSTANCES MAY NOT BE AVAILABLE ILLUSTRATIVE PURPOSES...

Page 10: ...5 45 43 46 8 47 44 28 14 13 12 3 8 25 3 38 49 15 This drawing contains information confidential to Lang Manufacturing Inc No reproduction or disclosure of its CERTAIN INSTANCES MAY NOT BE AVAILABLE I...

Page 11: ...COMMON ALL 24 D9 Z8444 1 BRACKET MTG TOP LATCH ROD ALL 25 2C Z2992 2 BOLT 1 4 20X1 PHP STL NP ALL 26 2F Z7910 2 RETAINER SPRING ALL 27 D9 GR0253 1 BODY ASSY 10 ALL 28 2T Y2313 1 THERMOSTAT 118V 236V...

Page 12: ...HANDLE COMMON ALL 24 D9 Z8444 1 BRACKET MTG TOP LATCH ROD ALL 25 2C Z2992 2 BOLT 1 4 20X1 PHP STL NP ALL 26 2F Z7910 2 RETAINER SPRING ALL 27 D9 GR0253 1 BODY ASSY 10 ALL 28 2T Y2313 1 THERMOSTAT 118...

Page 13: ...L 23 2F Z8529 4 RETAINER HANDLE COMMON ALL 24 D9 Z8444 1 BRACKET MTG TOP LATCH ROD ALL 25 2C Z2992 12 BOLT 1 4 20X1 PHP STL NP ALL 26 2F Z7910 4 RETAINER SPRING ALL 27 D9 GR0255 1 BODY ASSY 20 ALL 28...

Page 14: ...16 STAR INTERNATIONAL HOLDINGS INC COMPANY Star Holman Lang Wells Bloomfield Toastmaster 10 Sunnen Drive St Louis MO 63143 U S A 314 781 2777 www star mfg com...

Reviews: