background image

8

28 GRN

30800-05

30304-16

40101-10

34 RED

33 BLK

35 GRN

23 YEL

24 YEL

25 BLK

26 

YEL

30802-04

27 GRN

29 

YEL

31 BLU

30 GRN

63 BLK

31601-07

37 

YEL

60 BLK

61 BLK

38 

YEL

39 GRN

43 BRN

11090-16

BLU

WHT

RED

BLK

BLK

BLU

WHT

RED

10 RED

19 RED

30700-06

5 RED 
6 WHT

7 BLU

32 BLU

WHT

WHT

WHT

20

19

18 
17

30303-06

30203-16

22 WHT

18 RED

13 WHT

45 BLK

45 BLK

48 BLK

12 RED

10 WHT

11 WHT

31400-10

48 

YEL

47 

YEL

36 RED

42 BRN

19 RED

21 WHT

40 BRN

41 BRN

30701-05

30200-17

17 BLK

XFMR

46 BLK

26 

YEL

PRL

30900-10

FUSE

CNTR

BOTT

OM

TOP

PULSE LAMP

38 

YEL

29 

YEL

PRL

28 PRL

T-BLOCK

30501-02

ARKLESS CONNECT

OR

D

D

HIGH

LO

14 RED

15 BLK

16 BLU

-AP

1

1

2

3

4

5

RTD

SWITCH

POSITION

12

10

9

8

7

6

5

4

3

2

TIMER

24V

AC

NO

C

NC

24V

AC

3667W

-240V

3667W

-240V

2750W

-3667W

2750W

-208V

2750W

-208V

2750W

-208V

3667W

-240V

= WIRE NUT

TOP

C

FROM

PULSE

"HEA

T"

LIGHT

PULSE MODE

ON

C

CONTROL

24V

AC

HEA

T LIGHT

2-SPEED SWITCH

CONTROL

-AP

HIGH-LI

MIT

DISC-ST

AT

SWITCH

POWER

SWITCH

FUSES

FIRST

 DECK

CIRCUIT

 BREAKERS

31800-04

MOT

OR

OVEN LIGHTS

DOOR SWITCH

M

FROM MAIN CONT

ACT

OR

GRO

UND LUG

12 POLE TERMI

NAL

 BLOCK

D

C

B

SECOND DECK CIRCUIT

 BREAKERS

5

6

7

8

4

3

2

1

SECOND DECK WIRING IDENTICAL FIRST

 DECK

FROM MAIN CONT

ACT

OR

240V

AC

LIGHT

24

240

B

D

C

24V

AC

MAIN

CONT

ACT

OR

FUSE

1

2

3

3

2

1

D

C

NC

NO

P1

T9

T7-T4

BUZZER

D

HEA

T

50

54

52

53

57

55

51

55

53

52

54

51

57

56

50

HEA

TING ELEMENT

TERMI

NALS

REAR 

VIEW

N

FUSE MOUNT ECCO-226

13 WHT

12 RED

10 RED

FUSE HOLDER

30901-08

11 WHT

TIE WRAP

DWG.  NO:

SHEET

OF

DESCRIPTION:

W/D   ECCO-AP

 220/308V

AC 4 WIRE & 240/415V

AC 4 WIRE

61

11

1-173

REV

:

1

A

1

V

O

LT

S

L1

-N

L2

-N

L3

-N

TO

TA

L

L1

L2

L3

N

eu

tra

l

1

D

E

C

K

22

0/

38

0

3.

10

3.

10

3.

10

9.

30

14

.1

14

.1

14

.1

14

.1

1

D

E

C

K

22

0/

38

0

6.

20

6.

20

6.

20

18

.6

0

28

.2

28

.2

28

.2

28

.2

2

D

E

C

K

24

0/

41

5

3.

70

3.

70

3.

70

11

.1

0

15

.4

15

.4

15

.4

15

.4

2

D

E

C

K

24

0/

41

5

7.

40

7.

40

7.

40

22

.2

0

30

.8

30

.8

30

.8

30

.8

L1

L2

L3

N

1

D

E

C

K

1

2

3

N

2

D

E

C

K

1,

4

2,

5

3,

6

N

,N

K

W

A

M

P

S

S

E

R

V

IC

E

C

O

N

N

E

C

TI

O

N

S

Summary of Contents for ECOD-AP

Page 1: ...IL1519 ELECTRIC FULL SIZE COMPUTERIZED CONVECTION OVEN ECOD AP ECOF AP Installation and Operation Instructions 2M W488 Rev D 2 5 09 ECOF AP...

Page 2: ...ERVICE PERSONNEL ONLY NOTICE Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all liability Star reserves the right to change speci cations and product design...

Page 3: ...bleshooting Symptoms Possible Causes Test 16 Wiring Diagram 208 240VAC 17 220V 308VAC 4 Wire 240V 415VAC 4 Wire 18 380V 480VAC 19 Exploded View Parts List 20 27 PROBLEMS QUESTIONS or CONCERNS Before y...

Page 4: ...2 7 8 GA 2 1 3 23 1 GA 8 8 8 8 5 5 4 GA 240V 1 1 3 11 5 6 GA 4 2 3 7 3 7 10 GA 2 1 3 23 2 GA 7 8 7 8 7 3 4 GA ECOD AP 480V ECCO APXD U 480V 1 60 3 11 5 15 6 15 6 10 5 14 GA ECOF AP ECCO AP C 208V 1 60...

Page 5: ...or of the oven is constructed of porcelainized stainless steel Operation The ECOD AP and ECOF AP ovens are forced air convection ovens with a vented oven cavity The air is driven by a 1 3 HP fan motor...

Page 6: ...n crating move the oven as near to its intended location as practical The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways U...

Page 7: ...l instructions follow the instructions provided with the kit 27 Leg Installation With unit in position fasten the two legs to the front corner pads then to the oven s front corners using the four 5 16...

Page 8: ...all 5 16 inch nuts with lock washers and flat washers Adapter to Oven Installation Gently tip the oven onto its back Place the front leg adapter into the front corers of the oven The holes without the...

Page 9: ...ch socket head bolts found in the stacking kit into the two front leg holes that match the holes in the top of the lower oven Install the socket head bolts with the heads of the bolt pointing away fro...

Page 10: ...loser than 4 inches from another oven on the right hand side control panel side Do not install the oven closer than 12 inches from an uncontrolled heat source char broiler etc on the right side Keep t...

Page 11: ...r the number of ovens being installed Wire size information can be found on the oven DATA PLATE or in the specifications section on page 4 208 240V ovens can be installed on both single and three phas...

Page 12: ...n Once oven has been turned on verify that the blower wheel is spinning freely in a clockwise position and that the elements are heating properly Confirm that both thermostat knob and timer knob move...

Page 13: ...gs will always give the same results If the results vary problems may be because of changes in the product preparation ECOF AP ECOD AP Control Panel The Control panel consists of the following items D...

Page 14: ...quipment The same control settings will always give the same results If the results vary problems may be because of product preparation Opening the vent will to allow mositure to escape the cooking ch...

Page 15: ...side the oven cavity using oven cleaner Using any harsh chemicals will result in the removal of the ETC coating and etching of the porcelain below it The oven interior should only be cleaned using a m...

Page 16: ...he list is followed by an asterisk the work should be done by a Lang factory authorized service representative USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY LANG OR THEIR AUTHORIZED DISTRI...

Page 17: ...1 WHT 10 WHT 12 RED BOTTOM 48 BLK 45 BLK 1 TOP 45 BLK 13 WHT 18 RED 22 WHT 30203 16 30303 06 17 18 19 20 WHT WHT WHT WHT 31800 01 32 BLU 7 BLU 6 WHT 5 RED 30700 06 59 BLU 58 BLU RED WHT BLU BLK BLK RE...

Page 18: ...C HEAT LIGHT 2 SPEED SWITCH CONTROL AP HIGH LIMIT DISC STAT SWITCH POWER SWITCH FUSES FIRST DECK CIRCUIT BREAKERS 31800 04 MOTOR OVEN LIGHTS DOOR SWITCH M FROM MAIN CONTACTOR GROUND LUG 12 POLE TERMIN...

Page 19: ...DENTICAL SECOND DECK OVEN LIGHTS 240 VAC 480 24 D LIGHT CONTACTOR MAIN 24VAC FIRST DECK MOTOR FUSE MOTOR FUSE 1 2 3 3 2 1 DOOR SWITCH D C NC NO P1 T9 T7 T4 2 SPEED SWITCH RTD D HEAT 50 54 56 52 53 57...

Page 20: ...Main Assembly 1 5 7 6 1 2 3 4 8 9 10 11 13 16 10 17 18 19 20 21 22 10 24 26 27 28 29 30 46 48 49 1 4 10 50 51 47 32 33 34 35 36 41 42 43 44 45 37 38 39 40 31 23 25 Detail A Control Panel Assy Detail B...

Page 21: ...N 5 8IDX3 4ODX1 ECOF ECOD 25 2C 20115 01 8 SCRW S S 8 32X1 2 P H S T ECOF ECOD 26 2C 20203 03 4 WSHR FLT SS 5 16 USS ECOF ECOD 27 2C 20204 06 4 WSHR S S 5 16 SPLIT LOCK ECOF ECOD 28 2C 20111 07 4 SCRW...

Page 22: ...ECO DEEP OVEN ONLY ECOD Model No ECOF ECOD Main Assembly Commercial Marine Full Size Electric Convection Oven PARTS LIST June 30 2008 Rev C IMPORTANT WHEN ORDERING SPECIFY VOLTAGE OR TYPE GAS DESIRED...

Page 23: ...ECOF D ACCU PLUS Control Panel Assy Electric Full Size Convection Oven 3 2 6 7 11 9 14 16 19 20 24 26 28 Suggested Marine Parts Stocking 1 2 3 4 5 12 15 16 20 21 22 27 23 10 6 8 9 13 17 10 18 24 25 26...

Page 24: ...JFA ECCOPAP KFA 2E 30303 06 3 SWT TOG ON ON DPDT BLK ECCOPAP C ECCOPAP K ECCOPAP U 2E 30305 01 1 SWT INF 240V 15AMP ECCOPAP JFA ECCOPAP KFA 8 2E 30304 16 1 CIR BD SWITCH 140 450 F ECCOPAP C ECCOPAP JF...

Page 25: ...K ECCOPAP KFA ECCOPAP U 23 2C 20101 26 4 SCRW MS PLT 6 32 X 25 ECCOPAP JFA ECCOPAP K ECCOPAP KFA ECCOPAP U 2C 20101 26 6 SCRW MS PLT 6 32 X 25 ECCOPAP C 24 2J 30802 04 1 BUZZER ELEC 24V AC PIEZIO ECC...

Page 26: ...7 Rev A 6 03 08 ECOF CAN MOTOR ASSEMLBY Detail B 16 8 28 33 34 Suggested Marine Parts Stocking 1 2 3 4 5 6 7 8 9 10 14 17 4 18 19 20 21 13 15 22 13 23 25 26 27 35 28 30 31 27 32 33 34 29 24 15 16 11 1...

Page 27: ...0VM ECOD AP 480V 2U 30200 17 1 MTR 1 3HP208 240V1PH2SPD ECOF AP ECOD AP 2U 30200 53 1 MTR 1 3HP240 254V50HZ2SP ECOF AP2 4FA 2U 30200 60 1 MTR 1 3HP380V1PH50HZ2SP ECOF AP 380V ECOF AP380FA 17 2C 20118...

Page 28: ...STAR MANUFACTURING 10 Sunnen Drive St Louis MO 63143 U S A 800 807 9054 314 781 2777 Parts Service 800 807 9054 www star mfg com...

Reviews: