INSTALLATION
DANGER:
THIS APPLIANCE MUST BE GROUNDED AT THE
TERMINAL PROVIDED. FAILURE TO GROUND THE
APPLIANCE COULD RESULT IN ELECTROCUTION AND
DEATH.
WARNING:
INSTALLATION OF THE UNIT MUST BE DONE BY
PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY.
IMPROPER INSTALLATION CAN CAUSE INJURY TO
PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT
MUST BE INSTALLED IN ACCORDANCE WITH ALL
APPLICABLE CODES.
NOTICE:
The data plate is located behind the access cover to the
right of the oven door. The range voltage, wattage, serial
number, wire size, and clearance specifications are on the
data plate. This information should be carefully read and
understood before proceeding with the installation.
NOTICE:
The installation of any components such as a vent hood,
grease extractors, fire extinguisher systems, must
conform to their applicable National, State and locally
recognized installation standards.
4.1 Electrical Connection with an Overhead Switch Box
Electrical connection must be accomplished with 3 separate connections on remote
switch box, and 2 connections on the range. Connection #1 is for incoming power.
Connection #2 is for wires connecting switch box to range. Connection #3 is for
probe wires only. The probe wires must be connected from the range to the switch
box with a shielded cable. Grounded at one end only, running in a separate
conduit. Connections for the range are made on the terminal block located behind
an access panel to the right of the oven door. Recommend conduit be hooked into
the bottom front, below the terminal block, or at the right back of the unit behind
the terminal block.
4.2 Overhead Switch Box
The overhead switch box can be mounted anywhere above the range. The
electrical service connection can by made anywhere on the body of the switch box.
4.3 Range Voltage
The Lang Model CLR36R-GB-S can be operated on 440 Volts.