DANGER:
THIS APPLIANCE MUST BE GROUNDED AT THE
TERMINAL PROVIDED. FAILURE TO GROUND THE
APPLIANCE COULD RESULT IN ELECTROCUTION AND
DEATH.
WARNING:
INSTALLATION OF THE UNIT MUST BE DONE BY
PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY.
IMPROPER INSTALLATION CAN CAUSE INJURY TO
PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT
MUST BE INSTALLED IN ACCORDANCE WITH ALL
APPLICABLE CODES.
NOTICE:
The data plate is located behind the access panel in the
back of the grill. The griddle voltage, wattage, serial
number, wire size, and clearance specifications are on the
data plate. This information should be carefully read and
understood before proceeding with the installation.
NOTICE:
The installation of any components such as a vent hood,
grease extractors, fire extinguisher systems, must
conform to their applicable National, State and locally
recognized installation standards.
4.1 Electrical Connection
There is one power supply connection on the griddle. Refer to the power supply chart
on the bottom of this page for proper power supply size.
There is (1) one 1 1/4 inch conduit knockout on the griddle located at the rear of the
griddle, through the back and the bottom of the griddle body. Use a supply wire suitable
for at least 90
°
C.
4.2 Griddle Voltage
The model CLG-48A-S griddle is shipped from the factory wired for 440 volts.
4.3 Phasing
All griddles are shipped from the factory set up for a
three phase
service.
GRIDDLE SPECIFICATIONS
NOMINAL AMPS PER LINE
WEIGHT
THREE PHASE
440 VOLT
MODEL
NUMBER
TOTAL
kW
LINE 1
LINE 2
LINE 3
CLG-48A-S
24.0
35.4
35.4
23.6
515 lbs.