background image

 

4

 

IMPORTANT READ 

FIRST 

IMPORTANT

 

CAUTION:

 

THE FRYER WEIGHS 145 LBS. (65.91 KILOGRAMS).  
FOR SAFE HANDLING, INSTALLER SHOULD OBTAIN 
HELP AS NEEDED, OR EMPLOY APPROPRIATE 
MATERIALS HANDLING EQUIPMENT (SUCH AS A 
FORKLIFT, DOLLY, OR PALLET JACK) TO REMOVE 
THE UNIT FROM THE SKID AND MOVE IT TO THE 
PLACE OF INSTALLATION.

 

CAUTION:

 

ANY STAND, COUNTER OR OTHER DEVICE ON 
WHICH FRYER WILL BE LOCATED MUST BE 
DESIGNED TO SUPPORT THE WEIGHT OF THE 
FRYER (145 LBS.). 

CAUTION:

 

SHIPPING STRAPS ARE UNDER TENSION AND CAN 
SNAP BACK WHEN CUT. 

DANGER:

 

THIS APPLIANCE MUST BE GROUNDED AT THE 
TERMINAL PROVIDED.  FAILURE TO GROUND THE 
APPLIANCE COULD RESULT IN ELECTROCUTION 
AND DEATH. 

WARNING:

 

INSTALLATION OF THE UNIT MUST BE DONE BY 
PERSONNEL QUALIFIED TO WORK WITH 
ELECTRICITY.  IMPROPER INSTALLATION CAN 
CAUSE INJURY TO PERSONNEL AND/OR DAMAGE 
TO EQUIPMENT.  UNIT MUST BE INSTALLED IN 
ACCORDANCE WITH ALL APPLICABLE CODES. 

NOTICE: 

The data plate is located behind the front control 
panel.  The fryer voltage, wattage, serial number, wire 
size, and clearance specifications are on the data 
plate.  This information should be carefully read and 
understood before proceeding with the installation. 

NOTICE:

 

The installation of any components such as a vent 
hood, grease extractors, fire extinguisher systems, 
must conform to their applicable National, State and 
locally recognized installation standards. 

CAUTION:          

NEVER ENERGIZE THE HEATING ELEMENTS WITH 

NO OIL IN THE KETTLE OR WITH THE OIL LEVEL 
MORE THAN 3 INCHES FROM THE LOWER FILL 
LEVEL.

 

CAUTION:

 

ALWAYS KEEP THE AREA NEAR THE APPLIANCE 
FREE FROM COMBUSTIBLE MATERIALS. 

CAUTION:

 

KEEP FLOOR IN FRONT OF EQUIPMENT CLEAN 
AND DRY.  IF SPILLS OCCUR, CLEAN IMMEDIATELY, 
TO AVOID THE DANGER OF SLIPS OR FALLS. 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for CLF-15-S

Page 1: ...Company 6500 Merrill Creek Parkway Everett WA 98203 Phone 425 349 2400 Fax 425 349 2733 WWW LANGWORLD COM Copyright 2000 Installation Operation Maintenance Troubleshooting Model CLF 15 S Electric Cruise Line Fryer Serial ...

Page 2: ...RNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT NOTICE THIS EQUIPMENT IS APPROVED FOR INSTALLATION ONLY ON VESSELS GREATER THAN 65 FEET IN LENGTH IN ACCORDANCE WITH USCG REGULATIONS IN TITLE 46 CFR 110 113 ANY WIRIN...

Page 3: ...1 TABLE OF CONTENTS 3 2 READ FIRST 4 3 UNPACKING 6 4 INSTALLATION 7 5 INITIAL START UP 8 6 OPERATION 9 7 CLEANING MAINTENANCE PROCEDURES 10 8 TROUBLESHOOTING 12 9 PARTS LISTS 14 10 EXPLODED VIEW 16 11 WIRING DIAGRAMS 19 12 WARRANTY 20 ...

Page 4: ...PER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTICE The data plate is located behind the front control panel The fryer voltage wattage serial number wire size and clearance specifications are on the data plate This information should be carefully read and understood before proceeding with the installation N...

Page 5: ... AND FOLLOW THE DIRECTIONS ON THE LABEL OF THE CLEANER TO BE USED NOTICE Service on this or any other LANG appliance must be performed by qualified personnel only Consult your authorized service station directory or call the factory at 1 800 224 LANG 5264 or WWW LANGWORLD COM for the service station nearest you WARNING BOTH HIGH AND LOW VOLTAGES ARE PRESENT INSIDE THIS APPLIANCE WHEN THE UNIT IS P...

Page 6: ...ts intended location as practical The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways 3 3 Un crating The fryer will arrive completely assembled inside a wood frame covered by cardboard box and strapped to a skid Remove the cardboard cover cut the straps and remove the wood frame CAUTION FRYER WEIGHS 145 LBS 65 91 kilogram...

Page 7: ...understood before proceeding with the installation NOTICE The installation of any components such as a vent hood grease extractors fire extinguisher systems must conform to their applicable National State and locally recognized installation standards 4 1 Electrical Connection Electrical service may be made through a standard 1 inch conduit A hole should be cut out in one of two locations the first...

Page 8: ...eat to 200 F and let stand for 30 minutes After 30 minutes drain water and vinegar mix see operation section for instructions Be sure to wipe out and dry fry pot to remove any water spots Fill levels There are two fill marks on the sides of the fryer kettle The lower level indicates the fill mark with the elements out the upper level indicates the fill mark when the elements are lowered Fill and m...

Page 9: ...ed to the heating elements The lamp marked overtemp will illuminate if the oil reaches an over temperature condition The over temperature thermostat shuts off the fryer before the oil reaches a dangerously high temperature 6 2 Heating Elements The elements may be raised and locked in the up position The latch is located on the rear top surface of the fryer and may be activated by lifting the handl...

Page 10: ...brush 8 Flush out scrapings and sediment with a small quantity of hot oil and allow to drain thoroughly 9 Close drain valve and fill with a commercial fryer cleaning agent or soapy solution of non corrosive grease dissolving cleaner 10 Lower heating elements and set selector switch to 250ºF be sure to read and follow cleaner manufactures instructions and boil solution for 15 to 20 minutes 11 Turn ...

Page 11: ...e brackets bulbs become loose the brackets that hold the bulbs should be tightened right away 7 5 Component Access All maintenance may be done from the front Opening the front by removing 4 bolts gains access to all circuitry with the exception of the thermostat which is located on the top where the thermostat knob is located To gain access to the safety thermostat the thermostat and element termi...

Page 12: ...yer unplugged from outlet Failed power cord or plug Failed power switch Failed pilot light Fryer will not heat Failed element Power switch is not ON Failed contactor Failed thermostat Failed transformer Tripped over temperature thermostat Product burning Product is cooked too long Failed thermostat Failed contactor Product under done Failed temperature sensor Failed circuit board Failed temperatur...

Page 13: ...e representative Possible Cause TEST Product is cooked too long No test available operational condition Failed thermostat Check poles on thermostat for continuity Failed element Remove the wires and check for continuity across the element Failed heat contactor Remove the wires from the contactor coil and check for continuity across the contactor coil connection Ensure the contactor moveable points...

Page 14: ...rt C28 136 CL 1 14 Stanchion Trimlock C28 540 CL 2 15 Head Pivot C28 137 CL 1 16 3 32 X 1 1 2 Stainless Steel Cotter Pin 71801 03 2 17 3 Feet of Black Rubber Lock 71100 03 1 18 Wire Cover C28 508 2 CL 1 19 Body Back C28 506 CL 1 20 Large 2 Pole Terminal Block 175 Amp 30500 11 2 21 2 Position Rotary Switch 30304 30 1 22 Contact Block 30304 31 1 23 3 Pole Contactor 35A 208 240 V 30700 05 2 24 15 Amp...

Page 15: ...arge Bulb Clip C28 167 CL 4 40 Small Bulb Clip C28 168 CL 2 41 Limitstat Bulb Spacer C28 168 1 CL 2 42 Element Washer C28 160 CL 6 43 Over Temperature Thermostat Insulator C28 131 2 1 44 Over Temperature Thermostat Spacer C28 131 1 CL 1 45 Element Clamp C28 161 1 46 Element 440 V 4 KW 11110 47 3 47 5 8 18 Stainless Steel Jam Nut 20303 14 6 48 Basket Hanger Assembly C28 531 CL 1 49 Head Wrap C28 13...

Page 16: ...16 ...

Page 17: ...17 28 51 52 ...

Page 18: ...18 ...

Page 19: ......

Page 20: ...cted by the repair Quartz elements are warranted for ninety 90 days from the date of installation II Damage during shipment is to be reported to the carrier is not covered under this warranty and is the sole responsibility of purchaser user III Replacement components will be shipped F O B factory with freight prepaid Replacement component damage related to shipment is not covered under this warran...

Reviews: