INITIAL START UP

 

6.1 Initial Lighting Procedure 

Clean the preservative coating from the griddle plate and splash guard.  Add a mild 
detergent to hot water and wash the griddle plate and splash guard.  Rinse with a 
damp sponge and dry with a clean rag. 

WARNING:

 

BEFORE LIGHTING, USE A SOAP AND WATER 
SOLUTION TO TEST ALL JOINTS FOR GAS LEAKS. 

 

Plug the unit into a 115 volt power supply. 

 

Turn the ON-STANDBY toggle switch to ON. 

 

Set the temperature dials to the desired temperature. 

 

To turn the griddle off simply turn the main toggle switch to STANDBY.

 

6.2 Seasoning the Griddle Plate 

NON-CHROME ONLY

 

 

Set the temperature dials to 300

°

F (148°C). 

 

Observe the burners through the opening at the top of the control panel. 

 

When the burners go OFF, apply a thin coat of high-grade, non-salted 
vegetable oil to the griddle surface. 

 

Rub the oil into the griddle surface with the flat side of a spatula or a towel. 

 

Recoat any dry spots that appear then wait two minutes and wipe off any 
excess oil. 

 

Repeat the seasoning process at 350

°

F (176°C) and at 400

°

F (204°C). 

 

NOTICE:

 

During the first few hours of operation you may notice a 
small amount of smoke coming off the griddle, and a 
faint odor from the smoke.  This is normal for a new 
griddle and will disappear after the first few hours of 
use. 

 

 

 

Summary of Contents for 224SHG

Page 1: ...314 781 2777 Fax 314 781 2714 Rev F WWW STAR MFG COM July 9 2009 Installation Operations and Maintenance Instructions Gas Griddle Spark Ignition ACCU TEMP Model 224T 224TH 224THG 224SHG 236T 236THE 2...

Page 2: ...E INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT IMPORTANT The installation of the Appliance should conform to th...

Page 3: ...D FIRST 4 3 EQUIPMENT DESCRIPTION 6 4 UNPACKING 8 5 INSTALLATION 10 6 GRIDDLE SURFACE CARE 11 7 CHROME WARRANTY 12 8 INITIAL START UP 13 9 OPERATION 14 15 10 MAINTENANCE CLEANING PROCEDURES 16 11 TROU...

Page 4: ...O PERSONNEL AND OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTICE The data plate is located inside the control compartment of each griddle The griddle voltag...

Page 5: ...n cause corrosion CAUTION GRILL CALIBRATION REQUIRES DISASSEMBLY OF THE THERMOSTAT AND SHOULD BE PERFORMED BY QUALIFIED PERSONNEL ONLY IT IS GENERALLY MORE COST EFFECTIVE TO REPLACE A THERMOSTAT THAT...

Page 6: ...dle 3 2 Operation Each twelve inch section has its own snap action thermostat and gas valves that are fully on or fully off 3 3 Controls The ACCU TEMP Griddle comes with thermostat controls 3 4 Techni...

Page 7: ...2 SUPPLIED 272T 72 INCHES 162 000 162 000 TWO 3 4 NPT 115 VOLT 2 SUPPLIED SPECIFICATIONS AND INFORMATION GRILL SURFACE OVERALL CLEARANCE FROM COMBUSTIBLE SURFACES MODEL NUMBER WIDTH DEPTH SQUARE INCH...

Page 8: ...near its intended location as practical The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways 4 3 Un crating The griddle will...

Page 9: ...st be wired by a licensed electrician and in accordance with local codes or in the absence of local codes with NFPA No 70 latest edition in Canada use CSA STD C221 5 2 Gas Connection This griddle is m...

Page 10: ...ould be used that is resistant to the action of liquid petroleum gas Initial adjustments are the responsibility of the installer and are not chargeable to Star Manufacturing International After the gr...

Page 11: ...ash in the same way as an ordinary cooking utensil The drawers are removed by pulling forward until they are released from their track GRIDDLE CARE CHROMIUM SURFACES It takes very little time and effo...

Page 12: ...ncorporated or one of its authorized representatives that the chrome surface has been misused or abused or subjected to the following situations 1 Improperly installed 2 Incorrect voltage applied to e...

Page 13: ...h to STANDBY 6 2 Seasoning the Griddle Plate NON CHROME ONLY Set the temperature dials to 300 F 148 C Observe the burners through the opening at the top of the control panel When the burners go OFF ap...

Page 14: ...F 190 C 5 to 7 3 4 to 1 inch thick cooked medium 375 F 190 C 8 to 10 Lamb Chops 350 F 176 C 6 to 8 Pork Chops 350 F 176 C 6 to 8 Salmon 350 F 176 C 6 to 8 Halibut 325 F 162 C 6 to 8 Snapper 325 F 162...

Page 15: ...ddle temperature 7 2 Sequence of Operation When the griddle is connected to 115 Volt Power the spark module for each section starts sparking While they are sparking the solenoid valve for the pilot bu...

Page 16: ...COST EFFECTIVE TO REPLACE A THERMOSTAT THAT IS OUT OF CALIBRATION 8 1 Daily Cleaning Empty the grease drawer daily or whenever it is 3 4 full It is easily removed for washing Keep the non chromed gri...

Page 17: ...dials to 350 F 176 C Allow the burners to cycle ON and OFF at least five times before attempting to calibrate Place a surface thermometer in the center of each cooking section to be calibrated Allow...

Page 18: ...ify test procedures SYMPTON POSSIBLE CAUSE Entire griddle not lighting Failed regulator or plugged regulator vent Failed transformer Power indicator is not lit No power to cord outlet Griddle unplugge...

Page 19: ...ce thermostat Failed transformer Check transformer for correct voltage replace as necessary Failed igniter Replace as necessary Failed spark module Check for correct incoming voltage at module Failed...

Page 20: ...T 1 224T LP NATLR NAT TH LPMG TH NATCD TH NATMG T LPBK TH NAT THG NAT 2J 80201 24 PLT LT BURNR FR GEI12LEAD 1 224T LP NATLR NAT TH LPMG TH NATCD TH NATMG T LPBK TH NAT THG NAT 2J 80201 25 PLT LT BRNR...

Page 21: ...36T LP NAT THE NAT 2J 31601 07 PILOT LT 28V 6 LEAD WHT 1 236T LP NAT THE NAT 2J 80201 24 PLT LT BURNR FR GEI12LEAD 2 236T LP NAT THE NAT 2J 80201 25 PLT LT BRNR GEI LT 12 3S2 1 236T LP NAT THE NAT 2J...

Page 22: ...HOLE 4 248T LP NAT 2J 31601 07 PILOT LT 28V 6 LEAD WHT 1 248T LP NAT 2J 80201 24 PLT LT BURNR FR GEI12LEAD 3 248T LP NAT 2J 80201 25 PLT LT BRNR GEI LT 12 3S2 1 248T LP NAT 2J 80300 03 SPRK IGNITR MOD...

Page 23: ...AD WHT 1 260T LP NAT 2J 80201 24 PLT LT BURNR FR GEI12LEAD 4 260T LP NAT 2J 80201 25 PLT LT BRNR GEI LT 12 3S2 1 260T LP NAT 2J 80300 03 SPRK IGNITR MODULE SM2 5 260T LP NAT 2T 30402 27 STAT ADJ 450 D...

Page 24: ...42 HOLE 6 272T LP NAT 2J 31601 07 PILOT LT 28V 6 LEAD WHT 1 272T LP NAT 2J 80201 24 PLT LT BURNR FR GEI12LEAD 4 272T LP NAT 2J 80201 25 PLT LT BRNR GEI LT 12 3S2 2 272T LP NAT 2J 80300 03 SPRK IGNITR...

Page 25: ...25...

Page 26: ......

Page 27: ...ALVE THERMOSTAT THERMOSTAT THERMOSTAT THERMOSTAT THERMOSTAT TERMINAL BLOCK POWER CORD YEL YEL 12 YEL 13 YEL 20 YEL 27 YEL 34 YEL 41 YEL 48 YEL BLK BLK WHT WHT GRN BLK BLK 7 BLK 14 BLK 21 BLK 28 BLK 35...

Page 28: ...STAR MANUFACTURING GROUP Star Holman Lang Wells Bloomfield 10 Sunnen Drive St Louis MO 63143 U S A 800 807 9054 314 781 2777 Parts Service 800 807 9054 www star mfg com...

Reviews: