27
Page 1: ...CTRONIC ELECTRIC GRIDDLE Commercial Marine 124S 124SHE 124SCHE 136S 136S SC 136SHE 148S 148SHE 148SR 160S 160SHE 160SR 160S SC 172S 172SR 172SC Installation and Operation Instructions 2M W353 Rev I 1...
Page 2: ...IZED SERVICE PERSONNEL ONLY NOTICE Using any part other than genuine Lang factory supplied parts relieves the manufacturer of all liability Lang reserves the right to change specifications and product...
Page 3: ...le Causes 13 Possible Causes Test 14 Wiring Diagram 208 240VAC 15 480VAC 16 380VM 17 5 480V w CSE12 Hoods 18 Exploded View Parts List 19 27 PROBLEMS QUESTIONS or CONCERNS Before you proceed consult yo...
Page 4: ...0 x 24 0 x 28 2 243 lbs 280 lbs 85 381mm x 610mm x 717mm 110 kg 127 kg 136 15 0 x 36 0 x 28 2 368 lbs 410 lbs 381mm x 914mm x 717mm 167 kg 186 kg 148 15 0 x 48 0 x 28 2 Sides 2 483 lbs 515 lbs 381mm...
Page 5: ...0V 480 60 3 12 22 13 13 12 124SHE 208 240 60 1 3 12 58 4 50 29 29 6 124SHE 480F 480 60 3 12 22 13 13 12 124SCHE 208 240 60 1 3 12 58 4 50 29 29 6 136S 208 240 60 1 3 18 87 2 50 50 50 6 136S 380V 380 5...
Page 6: ...elve inch section of the griddle is controlled by an area sensitive RTD probe which can sense and react to a temperature change of 4 F Each twelve inch section has a set of 6 K W elements for high eff...
Page 7: ...un crating move the oven as near to its intended location as practical The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways...
Page 8: ...NEL AND OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTICE The data plate is located behind access panel between controls and grease drawer The grill voltage...
Page 9: ...al voltage design Jumper wires on terminal strip next to the main power supply connection determine the griddle voltage For a 208 volt power supply leave the jumpers in place For a 240 volt power supp...
Page 10: ...C for another hour and repeat this until it is at 450 F 232 C for hour The unit may emit a small amount of smoke as the cooking surface passes the 300 F 148 C point Do not be alarmed as the smoke is...
Page 11: ...front or back of the temperature sensor the thermostat will react to the temperature change much slower During slow periods with minimal loads do not load directly over the thermostat sensors as this...
Page 12: ...surface sparkling clean and performing at top efficiency DO NOT allow grease to accumulate as it will carbonize and become difficult to remove To prevent this condition the following cleaning suggesti...
Page 13: ...then refer to test to identify test procedures SYMPTOM POSSIBLE CAUSE Whole Griddle will not heat No Power to Griddle Failed Power switch Failed Transformer One Section will not heat Failed Power swi...
Page 14: ...F ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY LANG OR THEIR AUTHORIZED DISTRIBUTORS CAN CAUSE BODILY INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT AND WILL VOID ALL WARRANTIES POSSIBLE CAU...
Page 15: ...30 30 31 31 9 2 32 32 8 13 15 4 14 25 1 10 16 16 3 27 27 17 25 19 4 18 1 10 20 20 3 6 28 28 6 5 3 4 9 25 11 4 12 1 10 12 12 3 26 26 2 1 1 10 4 3 8 7 29 29 22 25 21 23 24 24 9 1 POSITION SWITCH 12 3 2...
Page 16: ...H 9 TRANSFORMER CLASS 2 10 PROBE 7 6 7 7 6 8 8 8 24V 480V NOTE SOME LG48 148S AND ALL LG60 160S LG72 172S HAVE TWO POWER SUPPLY CONNECTIONS LG48 148S CONN 1 USE LG24 124S CONN 2 USE LG24 124S LG60 160...
Page 17: ...2 3 L2 2 5 L3 3 6 CLAMSHELL HOOD BOX CONTACTOR GRIDDLE LEFT 18 17 17 16 14 14 13 8 3 32 31 7 31 30 GRIDDLE FIELD 30 30 31 31 32 7 32 11 3 7 DASHED COMPONENTS ARE 27 8 20 14 14 16 17 17 18 GRIDDLE RIGH...
Page 18: ...1 4 5 6 7 16 3 2 8 9 10 11 12 13 14 15 For individual parts SEE DETAIL A This drawing contains information confidential to Star Manufacturing International Inc No reproduction or disclosure of it s CE...
Page 19: ...LL 12 K9 XL 439 2 ELEMENT PAN Z ASSEMBLY ALL 13 2N 11030 29 2 ELE GRD 208 240V4 5KW 6KW 124S 124S 480V VM 124SHE 124SCHE 2N 11030 31 ELMNT GRID 480V 5991W 124S 480V 124SHE 480V 2N 11030 48 ELE GRD 440...
Page 20: ...L XL LG SEL 3 480V 136S 480V 7 K9 60102 13531 1 ACCESS PANEL ASSY 2 136S 136SB 136SC 8 K9 XL 235 1 1 GREASE BUCKET ASSY S S ALL K9 XL 235 30 GREASE BKT ASY REAR GUTER 136SR 9 K9 XL 441 3 PROBE HOLDER...
Page 21: ...REAR GUTER 148S WB 148SR 9 K9 XL 441 4 PROBE HOLDER SELECTRONIC ALL 10 K9 XL 434 4 ELEMENT PAN ASSEMLBY ALL 11 2H XL 424 4 ELEMENT PAN INSULATION ALL 12 K9 XL 439 4 ELEMENT PAN Z ASSEMBLY ALL 13 2N 11...
Page 22: ...S3 C PANEL XL LG SEL 3 208 240V 160S 160S SC K9 LGPS3 U PANEL XL LG SEL 3 480V 160S 480V 7 K9 60102 13531 1 ACCESS PANEL ASSY 2 160S 160S M 160S SC 160SHE 160SB 8 K9 XL 235 1 2 GREASE BUCKET ASSY S S...
Page 23: ...BE HOLDER SELECTRONIC ALL 10 K9 XL 434 6 ELEMENT PAN ASSEMLBY ALL 11 2H XL 424 6 ELEMENT PAN INSULATION ALL 12 K9 XL 439 6 ELEMENT PAN Z ASSEMBLY ALL 13 2N 11030 29 6 ELE GRD 208 240V4 5KW 6KW 172S 2N...
Page 24: ...24 1 2 3 8 5 10 11 2 12 1 13 14 15 16 16 20 9 7 6 18 19 17 2 4 Control Panel Assembly LPGS4 C shown SK2307 Rev B 7 7 08 DETAIL A...
Page 25: ...B LGPS2 CWB 172S 172S SC 2 PANEL XL LG SEL 3 208 240V LGPS3 C W1 172S 480V 2 PANEL XL LG SEL 3 480V LGPS3 U W1 Control Panel Parts Listing Fig No Part Number Qty Description Control Panel Assembly 1 K...
Page 26: ...LGPS3 C LGPS2 U 9 LGPS3 C LGPS3 U LGPS3 K 12 LGPS4 C LGPS4 U LGPS4 K 15 K9 XL 522 10 1 CIRC BRD MNT 4 LGPS4 C LGPS4 U LGPS4 K K9 XL 522 8 CIRCUIT BOARD MOUNT LGPS2 C LGPS2 U K9 XL 522 9 CIRC BOARD MO...
Page 27: ...27...
Page 28: ...28 STAR INTERNATIONAL HOLDINGS INC COMPANY Star Holman Lang Wells Bloomfield Toastmaster 10 Sunnen Drive St Louis MO 63143 U S A 314 678 6303 www star mfg com...