Laney VC15-110 Operating Instructions Manual Download Page 2

SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

WARNING:

 When using electric products, basic cautions should always be followed, including the

 

 following.

1.   Read all safety and operating instructions before using this product
2.   The product should be powered by a three pin `grounded (or earthed) plug connected to a power socket with a grounded earth outlet.
3.   All safety and operating instructions should be retained for future reference
4.   Obey all cautions in the Operating instructions and on the back of the unit
5.   All operating instructions should be followed
6.   This product should not be used near water, i.e. a bathtub, sink, swimming pool, wet basement, etc.
7.   This product should be located so that its position does not interfere with its proper ventilation. It should not be placed flat against a wall or placed in a built up enclosure that 

will impede the flow of cooling air.

8.  This product should not be placed near a source of heat such as stove, radiator, or another heat producing  amplifier.
9.   Connect only to a power supply of the type marker on the unit adjacent to the power supply cord.
10. Never break off the ground pin on a power supply cord. 
11. Power supply cords should always be handled carefully.  Never walk or place equipment on power supply cords. Periodically check cords for cuts or signs of stress, especially at  

the plug and the point where the chord exits the unit.

12. The power supply cord should be unplugged when the unit is to be unused for long periods of time.
13. If this product is to be mounted in an equipment rack, rear support should be provided.
14. The user should allow easy access to any mains plug, mains coupler and mains switch used in conjunction with this unit thus making it readily operable.
15. Metal parts can be cleaned with a damp cloth.  The vinyl covering used on some units can be cleaned with a damp cloth or ammonia based household cleaner if necessary.  

Disconnect the unit from the power supply before cleaning.   

16. Care should be taken so that objects do not fall and liquids are not spilled into the unit through any ventilation holes or openings.  On no account place drinks on the unit.
17. A qualified service technician should check the unit if:

18. The user should not attempt to service the equipment.  All service work is done by a qualified service technician.
19. Exposure to extremely high noise levels may cause a permanent hearing gloss.  Individuals vary considerably in susceptibility to noise induced hearing loss, but nearly everyone 

will lose some hearing if exposed to sufficiently intense noise for a sufficient time.  The U.S. Government's Occupational Safety and Health Administration (OSHA) has specified 
the following permissible noise level exposure.

        

    Duration Per Day In Hours

Sound Level dBA, slow response

90

6

92

4

95

3

97

2

100

1 ½

102

1

105

½

110

¼ or less              

115

According to OSHA, any exposure in excess of the above permissible limits could result in some hearing loss.  Ear plugs or protectors in the ear canals or over the ears must be 
worn when operating this amplification system in order to prevent a permanent hearing loss if exposure exceeds the limits set forth above.  To ensure against potentially dangerous 
exposure to high sound pressure levels it is recommended that all persons exposed to equipment capable of producing high sound pressure levels such as this amplification system 
be protected by hearing protectors while this unit is in operation.

!

The power cord has been damaged

!

Anything has fallen or spilled into the unit

!

The unit does not appear to operate correctly

!

The unit has been dropped or the enclosure damaged.

Page 2 /16

C1

1

V

5-

10

Summary of Contents for VC15-110

Page 1: ...ALL TUBE CLASS A B VINTAGE AMPLIFIER POWER TO THE MUSIC Laney C 0 V 15 11OPERATING INSTRUCTIONS 2 2 w w w l a n e y c o u k LA N E Y AM P L I F I C A T I O N ...

Page 2: ...aking it readily operable 15 Metal parts can be cleaned with a damp cloth The vinyl covering used on some units can be cleaned with a damp cloth or ammonia based household cleaner if necessary Disconnect the unit from the power supply before cleaning 16 Care should be taken so that objects do not fall and liquids are not spilled into the unit through any ventilation holes or openings On no account...

Page 3: ...es de decharge electrique ou de feu n exposez pas cet appareil a la pluie ou a l humidite Avant d utiliser cet appareil lisez les advertissments supplentaires situes dans le guide VORSICHT VORSICHT ACHTUNG Dieses Symbol soll den Anwender vor unsolierten gefahrlichen Spannungen innerhalb des Gehauses warnen die von Ausrichender Starke sind um einen elektrischen Schlag verursachen zu konnen Dieses S...

Page 4: ...eck the number with the explanations adjacent to each panel Your Laney amplifier has undergone a thorough two stage pre delivery inspection involving actual play testing When you first receive your Laney guitar amplifier follow these simple procedures i Ensure that the amplifier is the correct voltage for the country it is to be used in ii Connect your instrument with a high quality shielded instr...

Page 5: ...ier We hope you enjoy using yourVC15 as much as we enjoyed designing and making it Best wishes from all at Laney Laney OPERATING INSTRUCTIONS Dear Player Thank you very much for purchasing your new Laney product and becoming part of the worldwide Laney family Each and every Laney unit is designed and built with the utmost attention to care and detail so I trust yours will give you many years of en...

Page 6: ...at real retro sound and feel that only a quality tube amplifier can deliver Now use your guitar volume to control the amount of distortion Wind it up for distortion back it off a little for clean Adds brightness and life to the treble frequencies of your guitar when on the clean channel Adds edge and picking emphasis when on the drive channel The switch has more effect at low CleanVolume Drive con...

Page 7: ...ir ideal sound Try them all set at midway 5 as a good starting point REVERB Controls how loud the built in reverb sounds The reverb in theVC15 is a legendary Sound Enhancements aka Accutronics reverb the only choice for that authentic reverb sound The tone control works in a similar fashion to the Tone control you probably have on your guitar except that it uniquely works at the other end of the a...

Page 8: ...er USE ONLY THE CORRECT SIZE AND RATING FUSE AS SPECIFIED ON THE PANEL If a fuse blows or fails and a replacement of the same size and rating is installed and it in turn blows the amplifier has suffered a malfunction at this point check the output tubes and replace faulty ones if required Should tubes not be the problem the amplifier should be checked out by a qualified technician Do not try using...

Page 9: ...ts loop allows you to connect external effects such as tremolos chorus and delays to your amplifier Signal leaves the amplifier via the Send socket and comes back from the effects via the Return socket Some Effects are better suited to being between the guitar and amplifer input these are foot pedal types distortion wah wah pedals etc Rack mount effects will work better in the FX loop on the ampli...

Page 10: ...0 10 10 10 10 9 9 9 9 8 8 8 8 7 7 7 7 6 6 6 6 5 5 5 5 4 4 4 4 3 3 3 3 2 2 2 2 1 1 1 1 0 0 0 0 10 10 10 10 9 9 9 9 8 8 8 8 7 7 7 7 6 6 6 6 5 5 5 5 4 4 4 4 3 3 3 3 2 2 2 2 1 1 1 1 0 0 0 0 10 10 10 10 9 9 9 9 8 8 8 8 7 7 7 7 6 6 6 6 5 5 5 5 4 4 4 4 3 3 3 3 2 2 2 2 1 1 1 1 0 0 0 0 10 10 10 10 9 9 9 9 8 8 8 8 7 7 7 7 6 6 6 6 5 5 5 5 4 4 4 4 3 3 3 3 2 2 2 2 1 1 1 1 0 0 0 0 10 10 10 10 9 9 9 9 8 8 8 8 7 ...

Page 11: ... 2 2 2 1 1 1 1 0 0 0 0 10 10 10 10 9 9 9 9 8 8 8 8 7 7 7 7 6 6 6 6 5 5 5 5 4 4 4 4 3 3 3 3 2 2 2 2 1 1 1 1 0 0 0 0 10 10 10 10 9 9 9 9 8 8 8 8 7 7 7 7 6 6 6 6 5 5 5 5 4 4 4 4 3 3 3 3 2 2 2 2 1 1 1 1 0 0 0 0 10 10 10 10 9 9 9 9 8 8 8 8 7 7 7 7 6 6 6 6 5 5 5 5 4 4 4 4 3 3 3 3 2 2 2 2 1 1 1 1 0 0 0 0 10 10 10 10 9 9 9 9 8 8 8 8 7 7 7 7 6 6 6 6 5 5 5 5 4 4 4 4 3 3 3 3 2 2 2 2 1 1 1 1 0 0 0 0 10 10 10 ...

Page 12: ...at any regular interval Typical problems with preamp tubes can be a crackley noise hiss hum and microphony The preamp tubes can safely be changed with no action required if they fail or reduce in performance Typical output tube problems can be blown HT fuse sound lacking in punch sound lacks extreme highs or lows and low level hum The Output tubes can be replaced singularly if you replace them wit...

Page 13: ...l Number Input Laney Power To The Music www laney co uk DESIGNED IN THE UK BY LANEY 8 Ohms Link Model RB115 Power Rating 300W Program Model RB115 Power Rating 300W Program Serial Number Serial Number Input Laney Power To The Music www laney co uk DESIGNED IN THE UK BY LANEY SAMPLE GS412S VC15 110 SAMPLE SYSTEM 2 Input Output FX Controller Page 13 16 C1 1 V 5 10 ...

Page 14: ...ur guitar amplifier and then turn off its power before turning off other equipment Cables never use shielded or microphone cable for any speaker connections as this will not be substantial enough to handle the amplifier load and could cause damage to your amplifier system Caution These professional loudspeaker systems are capable of generating very high sound pressure levels Use care with placemen...

Page 15: ... of signal Bright Switch Input Impedance 1MOhm Size 368 450 205 Unit Weight 14 0 Kg Shipping Weight Loudspeaker outputs Extension speaker socket Disconnects Internal speaker Minimum 8 Ohm Impedance H W D 15 0 Kg This product conforms to the requirements of the following European Regulations Directives Rules CE Mark 93 68 EEC LowVoltage 72 23 EEC EMC 93 68 EEC RoHS EU2002 95 EC WEEE EU2002 96 EC In...

Page 16: ...roduct development Laney reserves the right to amend product specification without prior notification POWER TO THE MUSIC Laney JAZZ AMPICONS ARE HERE TO HELP BLUES ROCK METAL w w w l a n e y c o u k LA N E Y AM P L I F I C A T I O N ...