background image

CAUTION:

WARNING:

5. Do not use this apparatus near water. 

    b) The wire that is coloured blue must be connected to the terminal that is marked with the letter N or the colour black.

11. Only use attachments/accessories provided by the manufacturer.

8. Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus (including  amplifiers) that produce 

heat.

17. Note for UK only: If the colours of the wires in the mains lead of this unit do not correspond with the terminals in your plug‚ 

proceed as follows:

    a) The wire that is coloured green and yellow must be connected to the terminal that is marked by the letter E‚ the earth symbol‚ 

coloured green or

7. Do not block any of the ventilation openings. Install in accordance with manufacturer’s instructions. 

Risk of electrical shock - DO NOT OPEN. To reduce the risk of electrical shock, do not remove the cover.  No user 

serviceable parts inside.  Refer servicing to qualified personnel.

13. The mains plug or appliance coupler is used as the disconnect device and shall remain readily operable. The user should allow easy 

access to any mains plug, mains coupler and mains switch used in conjunction with this unit thus making it readily operable. Unplug 
this apparatus during lightning storms or when unused for long periods of time.

1. Read these instructions. 

20. Symbols & nomenclature used on the product and in the product manuals,  intended to alert the operator to areas where extra 

caution may be necessary, are as follows:

3. Heed all warnings.

9. An apparatus with Class I construction shall be connected to a mains socket outlet with a protective connection. Do not defeat the 

safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding 
type plug has two blades and a third grounding prong. The wide blade or third prong is provided for your safety. If the provided plug 
does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 

10. Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point they exit 

from the apparatus.

12. Use only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, 

use caution when moving the cart/apparatus combination to avoid injury from tip-over.

14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as 

when power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been 
exposed to rain or moisture, does not operate normally, or has been dropped.

16. If this product is to be mounted in an equipment rack, rear support should be provided.

4. Follow all instructions.

2. Keep these instructions safe.

WARNING: When using electrical products, basic cautions should always be followed, including the following:

6. Clean only with a dry cloth.

15. Never break off the ground pin. Connect only to a power supply of the type marked on the unit adjacent to the power supply 

cord.

         coloured green and yellow.

18.This electrical apparatus should not be exposed to dripping or splashing and care should be taken not to place objects containing 

liquids, such as vases, upon the apparatus.

19. Exposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary 

considerably in susceptibility to noise-induced hearing loss, but nearly everyone will lose some 
hearing if exposed to sufficiently intense noise for a sufficient time.

Intended to alert the user to the presence of high ‘Dangerous Voltage’ within the products enclosure that may be sufficient to 

constitute a risk of electrical shock to persons.

    c) The wire that is coloured brown must be connected to the terminal that is marked with the letter L or the colour red.

    The U.S. Government’s Occupational Safety and Health Administration (OSHA) has specified the 

following permissible noise level exposures: According to OSHA, any exposure in excess of the above 
permissible limits could result in some hearing loss. Earplugs or protectors to the ear canals or over 
the ears must be worn when operating this amplification system in order to prevent a permanent 
hearing loss, if exposure is in excess of the limits as set forth above. To ensure against potentially 
dangerous exposure to high sound pressure levels, it is recommended that all persons exposed to 
equipment capable of producing high sound pressure levels such as this amplification system be 
protected by hearing protectors while this unit is in operation.

Intended to alert the user of the presence of important operating and maintenance (Servicing) instructions in the literature 

accompanying the product.

If your appliance features a tilting mechanism or a kickback style 
cabinet, please use this design feature with caution. Due to the 
ease with which the amplifier can be moved between straight 
and tilted back positions, only use the amplifier on a level, 
stable surface. DO NOT operate the amplifier on a desk, 
table, shelf or otherwise unsuitable non-stable platform.

To prevent electrical shock or fire hazard, do not expose this 

appliance to rain or moisture.  Before using this appliance please 

read the operating instructions.

EN

Duration Per 

Day in Hours

8
6

¼ or less 

2

3

½

1 ½

4

1

slow response

115

105

102

90

97

95

100

92

Sound Level dBA, 

110

IMPORTANT SAFETY INSTRUCTIONS

Summary of Contents for Lionheart L5T-112

Page 1: ......

Page 2: ...for contemporary tones it also has a mean spiteful side to it as well making it ideal for any style of playing Perfect for studio and practice use but also equally at home or on stage plugged into a Laney LT212 cabinet the sound will blow you away Every Lionheart product is extensively play tested by experienced guitarists before being shipped to our customers Only when the unit is finished to our...

Page 3: ...ickups Also use this input for the cleanest full range sound with extended low end response Only use good quality guitar cable CLEAN VOLUME Sets how loud the clean channel is Try cranking it up a little to drive the power tubes harder for that real retro sound and feel that only a quality tube amplifier can deliver Now use your guitar volume to control the amount of distortion Wind it up for disto...

Page 4: ...tar controls playing weight and style DRIVE VOLUME Sets how loud the Drive channel is It is useful to experiment with drive levels and drive volumes If you want a very open warm and semi overdriven sound try reducing the amount of drive and increasing the drive volume This reduces pre amp gain but pushes the power amp section and makes it work harder giving you a very desirable level of power amp ...

Page 5: ...r end harmonics on the output stage and preamplifier overdrive sounds This will give you bright cutting sounds at high settings and smooth rounded sounds at lower settings Midway 5 is a good starting point STANDBY SWITCH Disconnects the main HT voltage from the tubes but keeps the tubes warm so that they are ready to go instantly Switch to standby for short breaks when you don t want to wait for t...

Page 6: ...lifier USE ONLY THE CORRECT SIZE AND RATING FUSE AS SPECIFIED ON THE PANEL If a fuse blows or fails and a replacement of the same size and rating is installed and it in turn blows the amplifier has suffered a malfunction at this point check the output tubes and replace faulty ones if required Should tubes not be the problem the amplifier should be checked out by a qualified technician Do not try u...

Page 7: ...f FX units with a 10dBu nominal output level As this is intended for devices wth a lower output level this switch increases the gain from the FX loop by 10dBu 0 dBu For connection of FX units with a 0 dbu nominal output level Bypass Removes the FX loop from the signal path FX SEND Mono jack socket for connection to the input of an external FX unit FOOTSWITCH SOCKET Provided for connection of the i...

Page 8: ...bes are more susceptible to damage than cool ones Use good quality loudspeaker leads cheap leads are often not up to the job of handling the large requirements for loudspeakers and can often short out Tube amplifiers don t like running into an open circuit A tubes life expectancy is based upon a number of factors which include operating temperature how hard and how often it is played vibration due...

Page 9: ...ifier Many products have large transient surges at turn on and off which can cause damage to your speakers By turning on your guitar amplifier LAST and making sure its volume controls are set to minimum any transients from other equipment will not reach your loudspeakers Wait until all system parts have stabilised usually a couple of seconds Similarly when turning off your system always turn down ...

Page 10: ...L5T 112 USER MANUAL EN www laney co uk 10 TUBE MAP REMOVAL TIPS TUBE TABLE V1 ECC83 005570 V2 ECC83 005570 V3 ECC83 005570 V4 EL84 005563 ...

Page 11: ...11 www laney co uk L5T 112 USER MANUAL EN ...

Page 12: ...L5T 112 USER MANUAL EN www laney co uk 12 QUICK START SETTINGS suggestions only USER SETTINGS ...

Page 13: ...13 www laney co uk L5T 112 USER MANUAL EN L5T 112 CONNECTIONS WITH FX WITH EXT CABINET FX ...

Page 14: ...uct GUITAR Amplifier Power 5 Watts RMS Channels Twin Channel Features Clean volume Bright switch Drive Drive volume Drive switch Bass Middle Treble Reverb Tone External Speaker socket FX loop LINE OUT send FX Loop Return Footswitch socket FS2 MINI Speaker 1 x Celestion G12H 70th Anniversary Unit Size mm 425x565x255 HxWxD Unit Weight 21 7 Kg Carton Size mm 550x660x350 HxWxD Packed Weight 23 4 Kg L5...

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ... has been exposed to rain or moisture does not operate normally or has been dropped 16 If this product is to be mounted in an equipment rack rear support should be provided 4 Follow all instructions 2 Keep these instructions safe WARNING When using electrical products basic cautions should always be followed including the following 6 Clean only with a dry cloth 15 Never break off the ground pin Co...

Page 19: ...to Cuando se use un carro tenga cuidado al mover el conjunto carro aparato para evitar que se dañe en un vuelco 6 Limpiar solamente con un trapo seco 19 La exposición a altos niveles de ruido puede causar una pérdida permanente en la audición La susceptibilidad a la pérdida de audición provocada por el ruido varía según la persona pero casi todo el mundo perderá algo de audición si se expone a un ...

Page 20: ...il 11 N utilisez que des fixations approuvées par le fabriquant 1 Lisez ces instructions 16 Si votre appareil est destiné à être monté en rack des supports arrière doivent être utilisés 17 Note pour le Royaume Uni Si les couleurs des fils du câble d alimentation ne correspondent pas aux fiches de la prise secteur procédez comme suit a Le fil vert et jaune doit être branché sur la borne repérée par...

Page 21: ...保证使用者及电 器的安全 如所提供的插头不适用于插座 须请专业人员更换 切勿自行更换电源插座 14 当该电器受到任何方式的损坏时 如 电源线或插头被损坏 液体泼溅或物体落入电器内 该电器放置于有雨水或潮湿 处 及该电器坠落后 无法正常运行 需进行检修时 必须请有资格认证的维修人员进行维修 a 黄绿色电缆须连接至标有字母 E 的电极 为接地符号 颜色为黄绿色或绿色 19 如果人处于极高噪音级中可能会造成永久失聪 每个人受噪音导致听力损害的差异很大 然而若 长时间处于极强噪音中 任何人几乎都会造成不同程度的听力损害 美国政府职业安全健康管理 局 OSHA 指定了以下允许范围内的噪音级别 见右表 根据OSHA 任何超出上述允许的极限 范围可导致不同程度的听力损害 在运行该电器时 人体处于超出了以上设定的限制 须佩戴耳 塞或配备耳朵的保护装置 以预防永久性听力损害 为避免可能处于强声压程度的危险 ...

Page 22: ...使用してください 付属の冊子に書かれている操作上 または管理上 サービス上 重要な事項を確認してください 激しい騒音の中にある一定の期間さらされた場合 を定めています OSHAによると 許容量を超える騒音は 製品カバーを開けないでください 感電の危険性を減らすためにも 蓋は取り外さないでください 必ず取扱説明書をお読みください アンプを使用しないときは スイッチをオフにし 電源コードは抜いてください 棚またはそれ以外の場合に不適切な nonstable プラットフォーム上増幅器を 安全上の重要な注意事項 電子機器を使用する際は 下記の注意事項に従ってご使用ください 掃除するときは 乾いた布のみを使用してください 通気孔は絶対に塞がないでください ラジエーター ヒートレジスター ストーブ等 熱を発する装置 アンプを含む の近くには決して置かないでください 電源コードは 踏まれたりはさまれたり...

Page 23: ...KR CAUTION WARNING ...

Page 24: ... chuva ou umidade não operar normalmente ou se tiver caído colorido em verde e amarelo b O fio é de cor azul que tem de ser ligado ao terminal que está marcada com a letra N ou a cor preta Segurança do Trabalho do governo dos EUA e Administração de Saúde OSHA especificou os seguintes exposições de nível de ruído admissíveis de acordo com OSHA a exposição em excesso dos limites admissíveis acima po...

Page 25: ...nicht in der Nähe von Wasser ein 6 Reinigen Sie es nur mit einem trockenen Tuch 7 Blockieren Sie keine der Lüftungsöffnungen Führen Sie die Installation gemäß den Anweisungen des Herstellers durch 11 Verwenden Sie nur die vom Hersteller erhältlichen Zubehörgeräte oder Zubehörteile 14 Lassen Sie sämtliche Wartungsarbeiten von qualifizierten Kundendiensttechnikern durchführen Eine Wartung ist erford...

Page 26: ...IT ...

Reviews: