VALVE REPLACEMENT AND TROUBLE SHOOTING
Laney
6
6
TECHNICAL SPECIFICATIONS
SOLUTION
3
Replace the secondary fuse and turn on the power. View the output valves. IF one valve fails to light up, replace that valve.
If the output valves check out OK, another cause of a blown secondary fuse is a damaged preamplifier valve. Start with valve
V1 and replace it. Follow the above procedure. If the symptom persists, consult a qualified engineer, do not fit higher rated
fuses.
SYMPTOM
4
No preamplifier boost
SOLUTION
4
Replace preamplifier tubes V1, V2 or V3 or a combination
SYMPTOM
5
Slow loss of power
SOLUTION
5
Check first for damaged output valves (glowing, flashing or dead) by using the procedures described in solution 3.
All of these trouble shooting procedures can be performed quickly, without the aid of any sophisticated test gear. We suggest
that you always maintain spare valves for emergency purposes. Keep you
Laney
free of dirt, dust and moisture to prevent
performance failure. Never subject your amp to environmental conditions that would not be comfortable to you!
Should other customer service be necessary, contact your authorised
Laney
dealer or call
Laney
service direct.
Laney
Maximum power consumption:
30
Watts
Supply voltage (Factory pre-set):
115/230
Volts
Supply
Frequency:
50/60Hz
Output power:
15
watts
Input impedance Hi & Lo:
1
Meg
Input sensitivity
Hi input:
100uV/-80dB
Input sensitivity Lo input:
200uV/-74dB
Line output level (nominal):
0dB
Line out impedance:
1K
Ohm
Speaker Impedance:
8
Ohms
Speaker size:
10"/250mm
Speaker
rating:
35
watts
HxWxD (mm):
355x385x250
*In the intrest of continuing product developement BLT Industries reserve the right to amend specifications without prior notice.
In the interest of continued product development BLT Industries Ltd. Reserves the right to amend product specification without prior notification.
POWER TO THE MUSIC
Laney