Laney Alliance VC50 User Manual Download Page 8

7

USEFUL HINTS AND TIPS

The following hints and tips are provided so that you can get the best performance out of your

valve amplifier. These are only

guidelines and should be adapted for your own preferences:-

Valve amplifiers take a short time to 'warm up' to optimum operating temperature. To get optimum performance out of your amp

allow the amplifier to 'warm up' for three mins. before you begin playing.

The position of an amplifier in a room has an effect upon the overall sound characteristics. If you wish to increase the bass

responce of your amplifier place the amplifier on the floor. If you wish to reduce the bass response of your amplifier place the
amplifier on a stand.

Do not place you amplifier hard up against a wall as this will reduce the air circulating around the back of the unit and may result in

overheating.

Laney

1:

2:

3:

4:

Connecting your guitar to either the 'HI' or 'LO' input has an effect on the sound, regardless of the guitar type/pickup

configuration. The 'HI' socket provides more gain. The 'LO' socket provides a lower gain. You should experiment with both inputs
to find the one which suits your guitar, style of playing and gives you the most tonally pleasing results.

VALVE REPLACEMENT AND TROUBLE SHOOTINGPS

VALVE REPLACEMENT AND TROUBLE SHOOTING

The valves in your new valve amplifier will eventually need replacing due to wear, this is normal with valve amps. In most instances
you should be able to effect valve replacement yourself without incurring the costs of a service engineer. Following are some of the
most likely symptoms of valve malfunction and a suggested method of correction.

Normally valve amps give optimum performance when fitted with matched sets of output valves as factory fitted to all

valve

amps. NB: Damage will not occur by not fitting matched sets although the amplifiers performance may be impaired.

Laney

VALVE IDENTIFICATION

SOLUTION 1

SYMPTOM 1

Check time delay POWER FUSE and replace if necessary:-
100-120 Volts 5 Amp time delay
220-240 Volts 2 Amp time delay

Amp connections have been performed correctly but power light fails to illuminate

SOLUTION 2

SYMPTOM 2

Power light illuminates, no sound out put

Check secondary HT fuse and if blown replace with

1 amp time delay

5:

When using the 'BRIGHT SWITCH' on the amplifier keep in mind that it has a greater audible effect the lower the amount of

distortion produced by the preamplifier. At some distortion levels the 'BRIGHT SWITCH' may appear to have no effect at all.

1

2

3

4

5

6

7

8

9

10

Pre Amplifier
input valves
6xECC83

Power Aamplifier
output valves
4x5881 matched quartet

1 First gain stage-Clean channel
2 2nd gain stage-Clean channel
3 First gain stage Drive channel
4 2nd gain stage Drive channel
5 3rd gain stage Drive channel
6 Power driver stage

7 & 8 2x5881 Output valves for VC50

7,8,9&10 4x5881 Output valves for VC100/VH100R.

VALVE FUNCTIONS

Summary of Contents for Alliance VC50

Page 1: ...MODEL VC50 Laney USER MANUAL VC100 VH100R Alliance...

Page 2: ...ritten for easy access of information The front and rear panels of each unit are graphically illustrated with each control and feature numbered For a description of the function of each control featur...

Page 3: ...6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 1 2 3 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 10 5 0 1 2 3 4 6 7 8 9 1...

Page 4: ...able Controls the low frequency EQ in the pre amplifier Controls the mid frequency EQ in the pre amplifier Controls the high frequency EQ in the pre amplifier Controls the level of reverb assigned to...

Page 5: ...L B CLEAN CHANNEL A VH100R BACK PANEL POWER FUSE HT FUSE LINE POWER AMP PRE AMP IN OUT 6L6 5881 EL34 BIAS FOOTSWITCH RETURN LEVEL INSERT SIDE CHAIN BYPASS RETURN SEND INSERT EFFECTS LOOP SEND RETURN R...

Page 6: ...ng of the amplifier When using with the on board speaker set to 8 ohms When an 8 ohm extension cabinet is also connected set to 4 ohms 1 4 output jack factory connected to the on board speaker With no...

Page 7: ...l mix is controlled via the front panel effects level control This socket is provided for use when a single effects unit is to be used on both channels at different mix levels via the front panel effe...

Page 8: ...replacing due to wear this is normal with valve amps In most instances you should be able to effect valve replacement yourself without incurring the costs of a service engineer Following are some of...

Page 9: ...ing flashing or dead by using the procedures described in symptom 3 Next check driver pre amp valve No 6 All of these trouble shooting procedures can be performed quickly without the aid of any sophis...

Page 10: ...NEWLYN ROAD CRADLEY HEATH WEST MIDLANDS B64 6BE GREAT BRITIAN In the interest of continuing product developement BLT Industries reserve the right to amend specifications without prior notice...