Lanex TR-55.1 Operation Manual Download Page 12

 

C

ONVERTER 

RS-232, RS-422, RS-485 

O

PERATION 

M

ANUAL

 

IOA55-1c  

 

August 

2009 

12

 

The converter should be connected with a cat. 5 twisted wire, of which the impedance of 

twisted wire pairs is 120 

. The maximum wire length to meet the requirements is 

1200 m.

 

However, it is not advisable to use such long connections. The length of a twisted wire should 
be limited in favour of the length of an optic-fibre wire.  

 

Figure 8. Power supply joint 

To connect the power supply we use two upper triple-contact sections of the connector 

in figure 8. In order to connect it, you should put the cable of the isolated power supply feeder 
or battery in the connector and screw its screws tight. Power supply polarization is any. There 
should be ground added to the connector in output 3 (first from the bottom).  
 

2.1.2. TR-55.2 

 

The device is equipped with the screw connector intended any signal and power wire.  

Optic-fibre wire should be connected by the agency of SC-type connectors (double, single for 
final converter version and two double or single ones for intermediate converter version). 
 

1     2     3     4     5     6     7     8     9 

 
 
 

Figure 9. Pin numbering of the screw connector 

 
 The

 

screw connector of the 

TR-55.2

 converter is adjusted for connecting to the serial 

computer port of the RS-232 standard or any other device equipped with a port of the RS-232, 
RS-422, RS-485 standards as well as power voltage 6-60 VDC.  The view of this connector is 
shown in figure 7. Table 1 shows description of specific outputs. 
 

Table 2. Specific pins description of the screw connector 

Function 

Pin number of screw 

connector 

RS-232 

RS-422 

RS-485 

 

TxD + 

D + 

TxD 

TxD - 

D - 

3 RxD 

RxD 

 

 

RxD -  

 

5 GND 

  

6  

SHIELD 

 


 

6-60 VDC 

9 Ground 

 

Summary of Contents for TR-55.1

Page 1: ...0 Lublin Poland tel 48 81 444 10 11 tel fax 48 81 740 35 70 IOA55 1c August 2009 LANEX S A Customer Technical Support 8 Ceramiczna Street 20 150 Lublin Poland tel 48 81 443 96 39 CONVERTER RS 232 RS 4...

Page 2: ...2 1 The RS 232 Interface 18 5 2 2 The RS 422 and RS 485 Interfaces 18 5 3 Mechanical Parameters 18 5 4 Environmental Requirements 18 5 4 1 Operation 18 5 4 2 Transport 19 5 5 Electromagnetic Compatibi...

Page 3: ...ase of a DC power supply to the device an easily accessible disconnecting system should be installed in the fixed wiring outside the device Radiation emitted by a laser transmitter is harmful to the e...

Page 4: ...le for the connection to use two fibres of a single mode or multi mode optic fibre or one fibre of a single mode optic fibre in the WDM technology The TR 55 converter is fully compatible with the ITU...

Page 5: ...iver working at the 1310nm wavelength 1310 1550nm transmitter working at the 1310 nm wavelength receiver working at the 1550nm wavelength 1550 1310nm transmitter working at the 1550 nm wavelength rece...

Page 6: ...5 1c August 2009 6 1 4 Examples of Different Uses for the Converter RS232 RS232 TR 55 TR 55 RS232 RS232 RS422 or RS485 TR 55 TR 55 Driver RS422 or RS485 bus RS232 RS422 or RS485 TR 55 TR 55 Optic sing...

Page 7: ...r double fibre line Driver Driver Driver Driver Driver RS232 RS422 or RS485 TR 55 TR 55 TR 55 TR 55 Driver Driver Driver Two pair copper wire RS422 or RS485 bus RS232 RS422 or RS485 Converter units op...

Page 8: ...L IOA55 1c August 2009 8 RS422 or RS485 bus RS232 RS422 or RS485 TR 55 TR 55 Optic single or double fibre line Driver Driver Driver Driver Driver TR 55 TR 55 TR 55 Driver Driver Driver Two pair copper...

Page 9: ...converter with one optical port TR 55 6 60V DC Optical connectors Transmitter er Receiver RJ45 signal connector Power connector and ground TR 55 6 60V DC Optical connector Transmitter Receiver RJ45 si...

Page 10: ...nd ground TR 55 RS RS RS 232 422 485 1 2 3 4 5 6 7 8 9 TXD TXD RXD RXD TXD RXD D D GND SHIELD 6 60 VDC Transmitter receiver 1310 1550 lub 1550 1310 Optical connector Signal connector and power connect...

Page 11: ...for intermediate converter version 1 8 Figure 7 Pin numbering of the RJ 45 connector The RJ 45 socket of the TR 55 converter is adjusted for connecting to the serial computer port of the RS 232 stand...

Page 12: ...dded to the connector in output 3 first from the bottom 2 1 2 TR 55 2 The device is equipped with the screw connector intended any signal and power wire Optic fibre wire should be connected by the age...

Page 13: ...version the device is equipped with either 2 or 3 signalling parts Their arrangement on the front panel is shown in figure 10 TR 55 6 60V DC Figure 10 The TR 55 converter signaling parts The signaling...

Page 14: ...dless of the number of these devices configuring one device as MASTER is necessary Yet the other devices have to be configured as SLAVE A different type of configuration may interfere with the working...

Page 15: ...tions complacent with point 5 3 of Operation Manual They should not be exposed to direct sunbeams It is unacceptable to clog ventilation holes 4 2 Installation The TR 55 device is adjusted to be mount...

Page 16: ...imum scopes of the transmission are compiled in table 4 Table 4 Estimated maximum scope along the electrical path RS 232 transmission speed Estimated maximum range for a twisted wire category 5 0 4 mm...

Page 17: ...rs Optic fibre connectors are devices of extremely high precision and require handling with care You should protect them from dust and dirt Disconnected parts of the connector should be protected with...

Page 18: ...ge level L VA VB 0 3V H VA VB 0 3V Differential output impedance for the RS 422 and RS 485 converters is 120 5 3 Mechanical Parameters Table 9 Mechanical parameters of the TR 55 converter Feature Valu...

Page 19: ...ce emission as described in the PN EN 55022 standard under the condition that they are installed in accordance with this instruction Caution The device is of class A In living conditions it may cause...

Page 20: ...CONVERTER RS 232 RS 422 RS 485 OPERATION MANUAL IOA55 1c August 2009 20...

Page 21: ...MANUAL IOA55 1c August 2009 21 Produced in Lanex S A 8 Ceramiczna Street 20 150 Lublin Poland tel 48 81 444 10 11 fax 48 81 740 35 70 e mail info lanex pl web www lanex pl Customer Technical Support N...

Reviews: