10Base-T/100Base-TX/E3 Converter
Operating Manual
IOA170-1A 22
January 2006
•
DHCP – server
frames filtering; OFFER and ACKNOWLEDGE packet filtering
6.4.2.2 Tab – Ethernet – Monitoring
Fig. 6-10. Interfaces– Ethernet, Monitoring.
The tab enables viewing the Ethernet interface signal, the following parameters are
monitored
LINK1
– activity of port 1
LINK2
– activity of port 2
LANPacketRXCnt
–
number of packets received from Ethernet interface
LANErrPacketRXCnt
–
number of errored packets received from Ethernet interface
LANFCtrlPacketRXCnt
–
number of packets with flow control received from Ethernet interface
LANFCtrlPacketTXCnt
–
number of packets with flow control sent from Ethernet interface
WANPacketRXCnt
–
number of packets received from E3
WANErrPacketRXCnt
–
number of errored packets received from E3
WANFCtrlPacketRXCnt
-
number of packets with flow control received from ES interface
WANFCtrlPacketTXCnt
-
number of packets with flow control sent from to ES interface