OPERATION
F-661R4
3-9
If a password is set, you will not be able to adjust the
pulses per mile.
Width
Press the
*
/FUNC
button until the “
WIDTH
” LED is lit.
The number displayed is the length of your implement in
feet.
To adjust the width, press the
UP
and
DOWN
buttons. If a
password has been entered, you will not be able to adjust
the width.
The length can be adjusted from .1 to 99.9 feet, in tenths
of a foot.
Acre Meter Password
The password function allows you to protect the total acre
count, pulses per 400 feet, and width settings with a
password. This stops anyone from accidentally changing
those settings. When the acre counter is shipped, the
password is disabled. You can modify the pulses per 400
feet and implement width at any time.
Press the
*
/FUNC
button until the “
PASS
” LED is lit. The
digits will display the word “
Ent
” or “
dIS
”.
If the display shows “
dIS
”: The password is disabled. The
total acre count, pulses/400 ft, width, and password
settings can be adjusted using the
UP
and
DOWN
buttons. The password can also be changed using the
UP
and
DOWN
buttons.
If the display shows “
Ent
”: You must enter your password
using the
UP
and
DOWN
buttons. When your password
is displayed, press the
*
/FUNC
button to test the
password. If the password is correct, you will be able to
change the acre counter settings. The password will be
viewable until the acre counter powers down. When the
acre counter is powered up again, you will have to
re-enter the password to change settings.
If the password is not correct, you will not be able to
change the acre counter settings. When the “
PASS
”
function is selected again, “
Ent
” will appear in the display.
Changing the Acre Meter Password
Select a new password using the
UP
and
DOWN
buttons.
Press the
*
/FUNC
button until the word “
SEt
” appears in
the display. Release the
*
/FUNC
button. The number in
the display is your new pass code. Make sure you record
this number. Press and hold the
*
/FUNC
button until the
word “
dIS
” appears in the display.
If the password is forgotten, it can be disabled by
removing the batteries. The password is intended for
rental units. It is recommended that a seal be affixed to
the rear plate of the acre counter to determine if the
settings have been tampered with.
Battery Replacement for Acre Meters
The battery operated acre counter uses 3 AA batteries.
The batteries should last between 5 and 10 years. The
acre counter will last much longer than that. Eventually,
you will have to replace the batteries. The “
BATT
” LED
will light when the batteries require replacement. Remove
the acre counter from the implement and undo the 4
screws on the back of the case. This will separate the
housing from the rear plate. Replace the batteries with 3
high quality AA alkaline batteries.
This unit is dust and splash resistant, under no
circumstances should this unit be submerged in any
conductive, corrosive, or flammable liquid.
Table 3-1: Acre Meter Settings
Wheel Type
Pulses
2P800
Notched Ductile
90
3P300
Optimizer
TBD
164639
Crowfoot
TBD
Summary of Contents for Brillion WFPD38-52
Page 2: ......
Page 45: ...ASSEMBLY F 661R4 2 31 Table provided for general use NOTES ...
Page 48: ...2 34 F 661R4 ASSEMBLY Table provided for general use NOTES ...
Page 58: ...3 10 F 661R4 OPERATION Table provided for general use NOTES ...
Page 63: ...MAINTENANCE F 661R4 4 5 Figure 4 3 Lubrication 2 of 2 UV UV UV UV UV 5HSDFN QQXDOO 3 2S UHDVH ...
Page 70: ...4 12 F 661R4 MAINTENANCE Table provided for general use NOTES ...