CALIBRATION AND PROGRAMMING
4-9
Figure 4-12: Pumps Screen
Pumps Screen
The “PUMPS” screen shot provides featured parameters
for the Plus 1 functions. See Figure 4-12.
Below is provided a definitions list for forklift
parameters: See Figure 4-12.
1.
0,3-RPM_Per_RampUp
- Time delay between actual
and commanded RPM
2.
0,3-RPM_Per_RampDown
- Time delay between
actual and commanded RPM
3.
0,3-PropelCmd_RampUp
- Time delay between
actual and commanded Propel command
4.
0,3-PropelCmd_RampDown
- Time delay between
actual and commanded Propel command
5.
0,3-MaxPumpFWD
– Defines the max current
supplied to the forward direction coil.
6.
0,3-MinPumpFWD
– Defines the min current
supplied to the forward direction coil.
7.
0,3-MaxPumpREV
– Defines the max current
supplied to the reverse direction coil.
8.
0,3-MinPumpREV
– Defines the min current
supplied to the reverse direction coil.
9.
0,3-RampDownDFWD
– Sets the decel rate when
changing direction. “Forward to reverse”. The lower
the value the more aggressive.
10.
0,3-RampDownCFWD
– Sets the decel rate when
letting up on the drive pedal. The lower the value the
more aggressive.
11.
0,3-RampDownBFWD
– Sets the decel rate when
applying the brake. The lower the value the more
aggressive.
Summary of Contents for Bendi B40i4
Page 2: ......
Page 26: ...1 20 F 581 R1 INTRODUCTION SAFETY AND INSPECTION...
Page 100: ...3 52 F 581 R1 TROUBLESHOOTING AND CORRECTIVE MAINTENANCE...
Page 120: ...4 20 F 581 R1 CALIBRATION AND PROGRAMMING...
Page 129: ...ENGINE WITH FUEL SYSTEM 5 9 Figure 5 10 Fuel System Troubleshooting...
Page 133: ...ENGINE WITH FUEL SYSTEM 5 13...
Page 134: ...5 14 F 581 R1 ENGINE WITH FUEL SYSTEM...
Page 140: ...6 2 F 581 R1 GM ENGINE SUPPLIER PROVIDED DOCUMENTATION...