background image

Assembly and operating manual

V

ERSION

12113

D

ATED

#2018

E

DITION

02/18

ZO

Ardor PTS+ 5.0+ 

Built-In

 

Read the operating instructions before using the device.

Please lift the operating instructions for future reference.

Summary of Contents for Ardor PTS+5.0+Built-In

Page 1: ...bly and operating manual VERSION 12113 DATEd 2018 EdITION 02 18ZO Ardor PTS 5 0 Built In Read the operating instructions before using the device Please lift the operating instructions for future refer...

Page 2: ...2 Ardor 1 3 2 4 5 6 7 8...

Page 3: ...der 9 Operation 10 Starting up the barbecue 10 Igniting the burners 10 Switching off the barbecue 11 Cleaning 11 Barbecue 11 Gas system 11 Maintenance 12 Barbecue 12 Gas system 12 Environmental inform...

Page 4: ...r G1 Pressure reducer Reduce gas pressure G2 Gas cylinder for bottle valve Fuel container G3 Rubber hose Directs gas to burner G4 Proper hose clip Fuel container G5 Regulator handle Cut off safety dev...

Page 5: ...for private use only Improper use Any other use or application beyond the intended purpose is not permitted This applies in particular to the following reasonably foreseeable types of improper use Do...

Page 6: ...and pets are kept away from the barbecue General safety instructions Failure to observe the following basic safety measures can result in severe injury to persons and substantial damage to property U...

Page 7: ...or fittings that are blocked with insects as this can result in a dan gerous flashback When igniting the gas flame do not bend over the barbecue as deflagration can occur if gas has accu mulated in t...

Page 8: ...xperienced at DIY assembly does not generally take longer than one hour The illustrations showing the assembly steps are at the end of this manual Connecting and disconnecting the gas cylinder Parts a...

Page 9: ...for leaks using a naked flame Listening for leaks is not a reliable method of detection If a leak is detected close the cylinder valve immedi ately and tighten the loose connection or replace the leak...

Page 10: ...gas Wait for 3 minutes to ensure that any accumula ted gas has dissipated Then re ignite the burners Caution Never run the infrared rear back burner when the main burners are running 1 Open the lid on...

Page 11: ...e areas around the burners with particular care To make sure that you enjoy your barbecue for many years you should always clean it after use after making sure that all the parts have cooled down with...

Page 12: ...us ignition of gas outside the burner Make sure that all parts of the barbecue are available and assembled visual check Check to ensure that all connections are present and securely fastened Tighten i...

Page 13: ...hose The igniter cable is not connected to the Piezo igniter Conduct a visual test connect if neces sary Distance between the spark plug and gas outlets on the burner is incorrect Visual inspection c...

Page 14: ...uantity Main burner Rear burner 4 x 3 5 kW 14 kW 3 5 kW Flow rate mass flow rate G30 1091 g h G31 1071g h Gas type Liquid gas propane Pressure regulator Preset and approved pressure regulator Flow rat...

Page 15: ...eel design Large drawers e g for BBQ accessories Ardor Island 12117 Steel frame with Hardie board design Work surface covered with two colour porcelain tiles Air supply through ventilation slots all a...

Page 16: ...16 Ardor 1 2 5 5 5 6...

Page 17: ...17 Ardor 3 4 1 7 8...

Page 18: ...18 Ardor 5 4 2...

Page 19: ...19 Ardor...

Page 20: ...le ventilation Always consult your local housing authority building inspector or contractor for clarification before proceeding with any construction Caution Please read all instructions before instal...

Page 21: ...red for building any outdoor kitchen Caution The island must be made out of non combustible mate rials In the event it is combustible the use of an insu lated jacket is required Minimum clearance to a...

Page 22: ...ovide 8 cm to 15 cm of overhang on all exposed sides The exhaust hood shall provide no less than 1200 CFM for proper exhaust ventilation Rear hood clearance A minimum of 14 6 cm clearance is required...

Page 23: ...or level The effectiveness of the opening s for purposes of ventilation shall be determined with the LP gas supply cylinder in place This shall be accom plished by one of the following Eeffective vent...

Page 24: ...24 Ardor 1 2 Gas Connection Steps The following steps will show you how to connect the gas supply system of 12113 and 12114 L 500mm...

Page 25: ...25 Ardor 3 4 NOTE If you want to use a side burner then they can be connected as shown in Figure 4 6...

Page 26: ...26 Ardor 5 6...

Page 27: ...pply leak testing solution by spraying on the pipe joints fittings and hose 5 A gas leak is detected if a There is a faint gas smell and or b Growing bubbles appear on any of the connection points and...

Page 28: ...ngdom Customer Service 014 80 42 17 20 www landmann co uk LANDMANN France 2 rue Gambetta 77210 Avon Tel 33 1 64 69 12 14 Email receptionfrance landmann de 1 IS LANDMANN Iceland ehf Grillb in ehf Smi j...

Reviews: