Order codes (type number key)
22/26
11
Order codes (type number key)
Order codes for label plate data
1. Type of meter and mounting location
Code
Heating meter for two wire temperature measure-
ment, mounting place cold side
A
Heating meter for two wire temperature measure-
ment, mounting place hot side
B
Cooling meter for two wire temperature measure-
ment, mounting place hot side (only in connection
with temperature sensor Pt500)
G
Cooling meter for two wire temperature measure-
ment, mounting place cold side
H
2. Nominal flowrate
Code
Nominal flowrate 0.6 m³/h, length 110 mm, nominal
pressure PN16, connection G ¾ B
05
Nominal flowrate 1.5 m³/h, length 110 mm, nominal
pressure PN16, connection G ¾ B
21
Nominal flowrate 1.5 m³/h, length 130 mm, nominal
pressure PN16, connection G 1
26
Nominal flowrate 2.5 m³/h, length 130 mm, nominal
pressure PN16, connection G 1 B
36
3. Control cable / type / electronic unit
Code
Split version with 1.5 m control cable
C
4. County / where used
Code
Dial plate for Middle East (English)
AE
Dial plate for Austria (German)
AT
Dial plate for Belarus (Russian)
BY
Dial plate for Switzerland (German/French)
CH
Dial plate for China (Chinese)
CN
Dial plate for Czech Republic (Czech)
CZ
Dial plate for Germany (German)
DE
Dial plate for Denmark (Danish)
DK
Dial plate English neutral
EN
Dial plate for Spain (Spanish)
ES
Dial plate for Great Britain (English)
GB
Dial plate for Italy (Italian)
IT
Dial plate for Norway (Norwegian)
NO
Dial plate for Poland (Polish)
PL
Dial plate for Russia (Russian)
RU
Dial plate for Sweden (Swedish)
SE
Dial plate for Slovenia (Slovenian)
SI
Dial plate for Slovak Republic (Slovakian)
SK
Dial plate for Uzbekistan (Russian)
UZ
5.
Manufacturer’s label
Code
Logo Gyr
00
Other labels on request
xx
6. Sensor type and method of connection
Code
Sensor Pt500, not removable, mounted in the tube
P
Sensor Pt500, not removable, mounting in the tube
as an option
Z
Hardware-dependent features
7. Sensor type
Code
Type PS, 16 bar / 95 °C / Ø5.0x45 mm, cable length
1.5 m
0F
Type PS, 16 bar / 95 °C/ Ø5.0x45 mm, cable length 5
m
0G
Type PS, 16 bar / 95 °C / Ø5.2x45 mm, cable length
1.5 m
0H
Type PS, 16 bar / 95 °C / Ø5.2x45 mm, cable length
5 m
0J
8. Power supply
Code
Standard battery for 6 years (1xAA cell)
A
Battery for 6 years (3xAA cells)
C
Battery for 11 years (2xAA cells)
E
Battery for 11 years (3xAA cells)
F
9. Communication
Code
No module
0
M-Bus module
B
Wireless M-Bus module 868 MHz
E
Pulse module
L
12. Calibration / conformity
Code
Certified acc. to national regulations
CL
Compliant to MID class 2
M2
Compliant to MID class 3
M3
Compliant with CEN 1434, class 2
T2
Compliant with CEN 1434, class 3
T3
Compliant acc. to national regulations
TL
13. Energy unit
Code
Display: kWh (until qp 2.5)
A
Display: MWh with 3 decimal places (until qp 2.5)
B
Display: MJ (until qp 2.5)
C
Display: GJ with 3 decimal places (until qp 2.5)
D
Further features
Measurement dynamics
Code
Dynamic range 1:100
C
Other ranges on request
*)
Additional ordering information needed (see page
23)
Type code:
T 2 3 0 - X X X X - X X X X - X - X X - X X - X X X
1. Meter type and mounting location
2. Nominal flowrate
3. Control cable/ type/ electronic unit
4. Country/ where used
5. Manufacturer's label
6. Sensor type and connection method
7. Sensor design
8. Power Supply
9. Communication
10. Calibration/ conformity
11. Energy unit
Mandatory data for the order designation
(label plate data)
Mandatory data for Hardware-
dependent features