Landis+Gyr T450 Operating Instructions Download Page 4

 

M-Bus module 

Subject to change without prior notice 

 

5. 

Adjustable parameters directly on the me-

ter 

5.1 

Calling the parametrizing function 

Proceed as follows to parameterize the meter: 

 

Press the service button for 3 sec. until the LCD displays 

.  

 

Press button 2 to adjust the parametrization.  

5.2 

Enter M-Bus primary address  

To enter the M-Bus primary address, proceed as follows: 
1. 

Press button 1 repeatedly until the LCD displays 

2. 

Press button 2 repeatedly until the digit you want to be 

modified flashes.  

3. 

Press button 1 repeatedly until the required value is 

being displayed on the LCD.  

You  can  repeat  steps 

2.

  and 

3.

  as  many  times  as  you  want 

until the required value appears. 
4. 

To confirm the entered value, press the button 1, mak-

ing sure that no more digits are flashing. 

5.3 

Enter M-Bus secondary address 

To enter the M-Bus secondary address, proceed as follows: 
1. 

Press button 1 repeatedly until the LCD displays 

2. 

Press button 2 repeatedly until the digit you want to be 

modified flashes.  

3. 

Press button 1 repeatedly until the required value is 

being displayed on the LCD. 

You  can  repeat  steps 

2.

  and 

3

.  as  many  times  as  you  want 

until the required value appears. 
4. 

To confirm the entered value, press the button 1, mak-

ing sure that no more digits are flashing.  

5.4 

Completing parameterization 

To complete the parameterization proceeds as follows: 

 

Press button 1 repeatedly until the LCD displays 

 

To switch into normal operation switch button 2.  

6. 

Adjustable parameters via M-Bus 

The parameters, as 

 

M-Bus primary address 

 

M-Bus secondary address 

 

Date and time 

can be parameterized via M-Bus.  
 
 
 

7. 

M-Bus data telegram 

Following  data  are  available  in  the  M-Bus  data  telegram  by 
default: 

 

Block number and application number 

 

Refreshment interval 

 

Current energy 

 

Current volume 

 

Current value tariff register 1 

 

Current value tariff register 2 

 

Current value tariff register 3 

 

Pulse input 1 meter number 

 

Current volume pulse input 1 

 

Pulse input 2 meter number 

 

Current volume pulse input 2 

 

Current power 

 

Current flow 

 

Current temperature hot side 

 

Current temperature cold side 

 

Current temperature difference 

 

Serial number 

 

Customer number 

 

Current value error time 

 

Current value operating time 

 

Error flags 

 

Prev. year value energy 

 

Prev. year value volume 

 

Prev. year value tariff register 1 

 

Prev. year value tariff register 2 

 

Prev. year value tariff register 3 

 

Prev. year storage day 

 

Prev. month value energy 

 

Prev. month value volume 

 

Prev. month value tariff register 1 

 

Prev. month value tariff register 2 

 

Prev. month value tariff register 3 

 

Prev. month storage day 

 

Meter time 

8. 

Technical data 

Standard 

EN 13757-2 

Conformity 

OMS 

Separation / Connection 

Galvanically coupled 

Power consumption 

Max. 1 M-Bus load (1.5 mA) 

Addressing meter 

Primary or secondary 

Addressing pulse inputs 

Primary or secondary 

Readout speed 
 
Readout frequency 

300 baud and 2400 baud with automatic baud rate 
detection 
1 time per minute at 2400 baud 
1 time per hour at 300 baud 

Recommended cable diameter 

 6 mm 

Recommended wire cross 
section 

0.25 

 0.75 mm² 

 

Gyr GmbH 

Humboldtstrasse 64 

90459 Nuremberg 

Germany 