Operational details
.
If the response limits are exceeded and the flow rate
and temperature difference are positive, the
quantity of heat
and the
volume
are summated.
With the
segment test,
all segments of the display
are activated to test the display itself.
On the
yearly
set day
the meter readings for the
quantity of heat and volume are placed in a
previous year's memory
identified with a
V.
*) With firmware versions 2.12 and 2.13 this function
is not possible together with fast pulses! The display
of S 00,01,-- means that the yearly set day is
deactivated).
The
flow rate,
the
heat output
, and the
differential
(temperature difference) are acquired with the
correct sign. If the lower response limit is violated, a
u
is displayed in front of the value. The current
temperatures
are displayed as integer values in °C
together on one display line.
The heat output and flow rateare averaged over the
measuring period
of, say, 60 min. The
maximum
values
of mean value calculation are marked with
an
M
in the leading position.
The 8-digit
property number
(secondary address
for M bus operation) can be set in parameterisation
mode. The most significant position is suppressed in
the display. The
unit number
is assigned by the
manufacturer.
The
time of operation
is counted from initial
connection of the power supply.
Time of downtime
is summated if a fault prevents the heat meter from
measuring. The
date
is incremented every day.
The
module type
is displayed. If an M bus module
is installed, the primary address is displayed on the
next line. A modem, analog modul or radio modul is
also displayed as M bus module.
The number of the
firmware version
is assigned by
the manufacturer.
Additional
The calculator may only be cleaned from the
outside. Use only a soft and wet cloth without any
aggressive detergent.
EC Declaration of conformity
Gyr herewith declares that this product
complies with the relevant requirements of the
following directives:
- 2004/22/EC Measuring instruments directive
- 89/336/EEC Electromagnetic compatibility
- 73/23/EEC Low voltage directive
EC type-examination certificate
DE-06-MI004-PTB005