LANDI RENZO S.p.A.

INSTALLATION AND ADJUSTMENT MANUAL LAMBDA CONTROL SYSTEM A1 V05

18 / 33

GB

LCS A1 V05 progr. functions

7.2 LCS A1 V05 PROGRAMMABLE FUNCTIONS
Here below are indicated the programmable
functions of LCS A1 V05 with relevant
programming  menu  and  options in which are
pointed out in bold type the standard parameters
settled with Computer new or resetted.

- NUMBER OF CYLINDER / TYPE OF IGNITION:
DOUBLE-COIL, SINGLE-COIL, 4/5/6/8 CYLINDERS

- RPM SIGNAL:
STANDARD, WEAK

- PETROL/GAS AUTOMATIC CHANGE:
IN 

DECELERATION, IN ACCELERATION, GAS

STARTING (only if enabled)

- PRIMING TIME: (only if enabled gas starting)
0,0 – 5,0 sec (0,8 sec)

- TEMPERATURE FOR CHANGE: (only if enabled)
20° - 40° (30°)

- RPM FOR AUTOMATIC CHANGE:
400 - 9.000 RP

(2.000 RPM)

- FUEL OVERLAPPING TIME DURING AUTOMATIC
CHANGE:
0,000 - 1,000 SEC. (0,400 SEC.)

- TPS (THROTTLE POSITION SENSOR):
LINEAR 0-5V, LINEAR 5 - 0V, SWITCH 0 - 12V,
SWITCH 12 - 0V, MONO BOSCH, TPS ADAPTER

- GAS LEVEL SENSOR:
LANDI RENZO, A.E.B., 0-90 OH

- LAMBDA SENSOR:
0 - 1V, 0,8 - 1,6V, 0 - 5V ‘A’, 0 - 5V ‘B’,
5 - 0V ‘A’, 5 - 0V ‘B,

- LAMBDA SENSOR READING DELAY:
0 - 1.250 SEC. (5 SEC.)

- LAMBDA SENSOR EMULATION:
SQUARE WAVE, DISCONNECTED, GROUND

- SQUARE WAVE EMULATION (only if selected previous
option): HIGH TIM

(0,36 SEC.), LOW TIME (0,36 SEC.),

DISCONNECTED SENSOR TIME (0,00 SEC.), NUMBER
OF WAVES AFTER DISCONNECTION (0)

- ACTUATOR-MAX DEVIATION IN ACCELERATION:
NOT ENABLED, 40 - 240 STEPS (100 

STEPS 

if

enabled)

- TPS DURING DEVIATION: (only if selected previous
option) 1,5 - 5,0V 

(2,8V)

LCS A1 V05 programmation
Malfunctioning diagnosis

- ACTUATOR-MAX HIGH POSITION:
20 - 240 STEPS (240 STEPS )

- TPS TO RELEASE LIMITATION: (only if selected
relevant options) 0,0 - 5,0V 

(2,8V)

- ACTUATOR-MAX LOW POSITION:
20 - 240 STEPS (20 STEPS )

- CUT-OFF OPTION:
NOT ENABLED, ENABLED

- MINIMUM RPM FOR CUT-OFF: (only if selected
previous option) 400 - 9.000 RP

(1.500 RPM)

- ACTUATOR-MAX POSITION FOR CUT- OFF: (only if
selected previous option) 40 - 240 STEPS 

(80 STEPS)

- ACTUATOR-MAX INCREASE IN ACCELERATION:
NOT ENABLED, ENABLED

- TPS DEVIATION FOR INCREASE: (only if selected
previous option) 0,1 - 3,0V 

(0,3V)

- NUMBER STEPS FOR INCREASE: (only if selected
previous option) 0 - 30 STEPS 

(5 STEPS)

- ACTUATOR-MAX POSITION FOR FIXED DEFAULT:
NOT ENABLED,  20  -  240  STEPS    (100 STEPS if
enabled)

- LCS A1 V05 MEMORY RESETTING: OK TO CONFIRM
allows to re-set the standard values (in bold type) of LCS
A1 V05 Computer

7.3  NOTES  CONCERNING  THE  LCS  A1 V05
PROGRAMMATION
The standard emulation of the lambda sensor is
settled as TYPE OF LAMBDA 

SENSOR

EMULATION 

Ì

 SQUARE WAVE. This kind of

emulation is used for the main part of the vehicles
and must be changed only if allowed from the
TECHNICAL MANUAL LANDI RENZO MT012.

The lambda sensor emulation of vehicles with

Monoinjector Bosch 

(for which the parameter

TYPE OF TPS 

Ì

 MONO BOSCH) is made

programming 

the 

parameter TYPE OF

EMULATION 

Ì

  GROUND.  On  this  vehicles the

yellow-blue  wire  of  LCS  A1  V05 must be
connected  to  the  wire  n.  2  (and  not to the wire n.
4) of the TPS connector at side of the throttle
body.

Summary of Contents for A1 V05

Page 1: ...TALLATION ET REGLAGE page 20 GUIA INSTALLACION Y REGULACION pag 27 LAMBDA CONTROL SYSTEM A1 V05 LPG CNG CONVERSION SYSTEMS FOR VEHICLES LANDI RENZO S p A Via F lli Cervi 75 2 42100 Reggio Emilia Italy...

Page 2: ...LANDI RENZO S p A LAMBDA CONTROL SYSTEM A1 V05 2 33 I Schema Tecnico Gpl GB Lpg Technical Drawing F Sch ma Technique Gpl E Esquema T cnico Glp Fig 1...

Page 3: ...S Y S T E M A 1 IT A LY LA N D I RE N ZO S p a LA N D I RE N ZO S p a LC S A G D G M 4 8 5 2 2 G PL D EL 2 4 1 9 4 LC S A G D G M 4 8 5 2 2 G PL D EL 2 4 1 9 4 LC S A M D G M 4 8 5 2 3 G M D EL 2 4 1...

Page 4: ...TROL SYSTEM A1 V05 5 33 I Schemi Tecnici GB Technical Drawings F Sch mas Techniques E Esquemas T cnicos 1 2 3 12 V 5 V Segnale TPS TPS signal Signal TPS Se al TPS Segnale TPS TPS signal Signal TPS Se...

Page 5: ...tem using a diagnostic connector with a diagnostic and programming instrument Programmer Tester V05 or Interface Kit V05 with dedicated software and serial interface for personal Computer Parts instal...

Page 6: ...mmended to solder listed wire connections and insulate them properly 6 1 RED BLACK AND BLACK WIRES lt N Fig 1 and 2 COMPUTERLCSA1V05 POWER SUPPL To deliver a continuous power to the system made follow...

Page 7: ...ellow wire of the LCS A1 V05 Electrical connections 6 4 BROWN WIRE lt M Fig 1 and 2 ENGINE RPM SIGNAL CONNECTION Connect the brown wire of LCS A1 V05 to the negative of the ignition coil or as an alte...

Page 8: ...functions of LCS A1 V05 can be set only by the Programmer Tester V05 or by a personal computer with Interface Kit V05 and dedicated software Also when the LCS A1 V05 is not fed ex batter disconnected...

Page 9: ...ed TPS DURING DEVIATION only if selected previous option 1 5 5 0V 2 8V LCS A1 V05 programmation Malfunctioning diagnosis ACTUATOR MAX HIGH POSITION 20 240 STEPS 240 STEPS TPS TO RELEASE LIMITATION onl...

Page 10: ...adequate option per option the parameters of LCS A1 V05 Computer to the specification of the vehicles see par 7 2 Carburation learning procedure GB d Check that the set values on LCS A1 V05 Computer...

Reviews: