![Landa ZG3-20321 Operator'S Manual Download Page 7](http://html1.mh-extra.com/html/landa/zg3-20321/zg3-20321_operators-manual_3948791007.webp)
ZG SERIES PRESSURE WASHER
OPERATOR’S MANUAL
7
LANDA ZG
•
REV. 5/02
HOW TO USE THE
DETERGENT INJECTOR
WARNING: Some detergents may
be harmful if inhaled or ingested
causing severe nausea, fainting
or poisoning. The harmful ele-
ments may cause property dam-
age or severe injury.
CAUTION: With machine off, open
spray gun to release pressure be-
fore removing discharge hose.
The machine can siphon and mix detergents with the
use of Landa's detergent injector kit.
1. Pull injector quick coupler collar back and secure on
discharge nipple. Injector valve body arrow should
point in direction of flow.
2. Connect pressure discharge hose to injector nipple
securing quick coupler.
3. Start machine as outlined in Operating Instructions.
4. Place detergent pick-up tube into container of deter-
gent solution.
5. Install the brass soap nozzle provided with the in-
jector into the quick coupler of the wand.
6. Pull trigger on spray gun. Water detergent ratio is
approximately 15 to 1.
7. When you finish washing, rinse by simply releasing
the trigger on the spray gun, removing the soap
nozzle, and replacing the pressure nozzle back into
quick coupler.
NOTE:
The detergent injector will not siphon with
the high pressure nozzle at the end of the wand.
8. For clean up, place detergent pick-up tube into con-
tainer of clear water and follow steps 5 and 7 to pre-
vent detergent deposits from damaging the injector.
WARNING
SOME DETERGENTS
MAY BE HARMFUL IF
INHALED OR
INGESTED
Spray
Gun
Trigger
High Pressure
Hose
Pressure Nozzle
Brass Soap
Nozzle
Quick Coupler
Quick
Coupler
Detergent
Injector
Collar
Detergent Bucket
(not included)
Wand
Wand
Detergent
Pick Up Tube
Summary of Contents for ZG3-20321