background image

ZE/ZEF-ET-HD-HE • 8.914-001.0, 8.941-457.0, 9.800-088.0, 8.919-017.0 • Rev. 12/12

9

  

PRESSURE W

ASHER 

  

OPERA

T

OR’S MANU

AL

  

Pump Storage

CAUTION: Always store your pres-
sure washer in a location where the 
temperature will not fall below 32° F 
(0° C). The pump in this machine is 
susceptible to permanent damage if 
frozen. 

FREEZE DAMAGE IS NOT COV-
ERED BY WARRANTY.

If you must store your pressure washer in a location 
where the temperature is below 32° F,  you can minimize 
the chance of damage to your machine by draining your 
machine as follows:

SHUTTING DOWN AND CLEAN-UP

STEP 1:

 Remove deter-

gent suction tube from 
container and insert into 
one gallon of fresh water. 
Slide nozzle forward for 
low pressure or to connect 
black detergent nozzle. 
Pull trigger on spray gun 
and siphon water for one 
minute.

STEP 2:

 Turn off machine 

by fl ipping switch on rear 
of motor or by pressing the 
switch on the remote con-
trol box (if equipped).

STEP 5:

 Disconnect the 

garden hose from the wa-
ter inlet on the machine.

STEP 6:

 Disconnect the 

high pressure hose from 
high pressure outlet.

STEP 7:

 Engage the spray 

gun safety lock.

STEP 4:

 Press trigger to 

release water pressure.

Pump 
Water 

Inlet

High 

Pressure 

Outlet

Safety 

Latch

STORAGE

CAUTION

STEP 3:

 Turn off water 

supply.

1.    Stop the pressure washer and detach supply hose 

and high pressure hose. Squeeze the trigger of the 
spray  gun to drain all water from the wand and 
hose.

2.    Restart pressure washer and let it run briefl y (about 

5 seconds) until water no longer discharges from 
the high pressure outlet.

Summary of Contents for ZE2-11026D

Page 1: ...11026D 1 106 023 0 ZEF2 14024D 1 107 090 0 ZE2 14024D 1 106 024 0 HOME DEPOT ZE ZEF 8 914 001 0 OPERATOR S MANUAL For technical assistance or the dealer nearest you consult our web page at www landa...

Page 2: ...cord both serial number and date of purchase and keep in a safe place for future reference ZE ZEF ET HD HE 8 914 001 0 8 941 457 0 9 800 088 0 8 919 017 0 Rev 12 12 Important Safety Information 4 5 Co...

Page 3: ...ct your electrician plumber utility company or the selling distributor for specific details If your machine is rated 250 volts or less single phase will be provided with a ground fault circuit interru...

Page 4: ...PROTECT FROM FREEZING WARNING Protect machine from freezing 13 To keep machine in best operating conditions it is important you protect machine from freezing Failure to protect machine from freezing...

Page 5: ...ops high pressure Spray Gun Controls the application of water and detergent onto cleaning surface with trigger device Includes safety latch Wand Must be connected to the spray gun Flex Wand Allows ope...

Page 6: ...tach nozzle extension to spray gun wand Tighten both by hand STEP 3 Pull the spring loaded col lar of the wand coupler back to insert your choice of pressure nozzle STEP 7 Connect the garden hose to p...

Page 7: ...Trigger the spray gun to eliminate trapped air then wait for a steady flow of water to emerge from the spray nozzle Cold Water Source Garden Hose WARNING Never replace nozzles without engaging the saf...

Page 8: ...ozzle forward for low pressure or to connect black detergent nozzle Pull trigger on spray gun and siphon water for one minute STEP 2 Turn off machine by flipping switch on rear of motor or by pressing...

Page 9: ...ve spring Check and replace if necessary Foreign matter in valves Check and clean if necessary Worn bearings Check and replace if necessary Water temperature excessive Reduce to below 160o F PRESENCE...

Page 10: ...s approximately every 500 hours of operation or every 3 months whichever occurs first Keep the motor clean and the ventilation openings clear The following steps should be performed at each inspection...

Page 11: ...8 914 001 0 8 941 457 0 9 800 088 0 8 919 017 0 Rev 12 12 OPERATOR S MANUAL PRESSURE WASHER 12 OPTIONAL WALL MOUNT 8 903 613 0 Instruction label should be placed next to the machine and within easy vi...

Page 12: ...wire HO Tuff Skin ET models 1 8 739 124 0 Hose 3 8 x 25 1 wire KA Tuff Skin HD and HE 1 3 9 802 223 0 Spray Gun Shut Off 1 4 9 802 220 0 Wand Straight 1 ITEM PART NO DESCRIPTION QTY 5 9 802 164 0 Cou...

Page 13: ...enter field labor charges or freight damage WHAT YOU MUST DO TO OBTAIN WARRANTY SERVICE While not required for warranty service we request that you register your LANDA pressure washer by returning the...

Page 14: ...Form 8 914 001 0 Revised 12 12 Printed in U S A or Mexico...

Reviews: