LANDA VHP • 8.913-949.0 • Rev. 5/13
11
PRESSURE W
ASHER
OPERA
TOR’S MANU
AL
variable pressure
Control handle
Trigger
variable pressure
Wand (vp)
high
pressure
nozzle
brass soap
nozzle
sTep 6: Selection of high or low pressure is ac-
companied by turning the handle.
note: High
pressure nozzle must be inserted at end of wand to
obtain high pressure. To apply soap read operator's
manual.
sTep 5: Release the coupler
collar and push the nozzle until
the collar clicks. Pull the nozzle to
make sure it is seated properly.
sTep 4: Pull the spring-loaded
collar of the wand coupler col-
lar back to insert your choice
of pressure nozzle.
CAUTION:
Never replace nozzles without
engaging the safety latch on
the spray gun trigger.
Coupler
Collar
operaTIng InsTruCTIons
sTep 3: Before installing nozzle, Pull
trigger on spray gun allowing water to flow
until all air has been discharged from the
system. Check for water leaks and tighten
as needed.
Grip spray gun variable pressure wand
securely. Then turn the variable pressure
control handle counterclockwise to flush
any debris out of soap nozzle.
89139490-6
pump and burner
switch
sTep 9: Turn switch to pump position and
pull the trigger on the spray gun. Turn vari-
able pressure control wand handle clockwise
to obtain pressure for cold water operation.
For hot water, turn the switch to the burner
position and pull the trigger on the spray gun.
To apply detergent, read section on Deter-
gents and General Cleaning Techniques.
sTep 7: Open valve on LP tank, then slightly depress
main gas valve control knob on the right side of the ma-
chine and turn it counterclockwise to the Pilot position.
noTe: Knob cannot be turned from “Pilot” to “OFF” unless
the knob is slightly depressed.
step 8: Depress the control knob all the way and hold it in. After
five (5) seconds, depress the red ignitor until you hear a loud click.
Repeat 3 or 4 times if necessary until pilot is lit. If pilot does not
remain lit, repeat operation allowing a longer period of time before
releasing the gas valve knob. After the pilot lights, continue to hold
the control knob down for about one (1) minute before releasing.
Look at the pilot viewing mirror at the rear of the machine.
Turn gas control knob counterclockwise to “ON.”
Control
knob
gas
valve
red
Ignitor