background image

6

Safety

WARNING: To reduce the risk of 
injury, read operating instructions 
carefully before using.

AVERTISSEMENT: Pour réduire le 
risque de blessures, lire attentive-
ment les instructions de 
fonctionnement avant l'utilisation

1. Read the engine and this 

owner's manual thoroughly. 

Failure to follow instructions could cause malfunc-
tion of the machine and result in death, serious 
bodily injury and/or property damage.

2. Know how to stop the machine and bleed pressure 

quickly. Be thoroughly familiar with the controls.

3. Stay alert — watch what you are doing.

WARNING: Keep wand, hose, and 
water spray away from electric 
wiring or fatal electric shock may 
result.

AVERTISSEMENT: Garder la 
lance, le boyau et le jet d'eau à 
l'écart de tout câblage électrique 
ou des chocs électriques mortels 
pourraient survenir

4. All installations must comply with local codes. 

Contact your electrician, plumber, utility company 
or the selling dealer for specific details.

WARNING: This machine exceeds 
85 db appropriate ear protection 
must be worn.

AVERTISSEMENT: Cette machine 
excède 85 dB et une protection de 
l'ouïe appropriée doit être portée.

WARNING: High pressure spray 
can cause paint chips or other 
particles to become airborne and 
fly at high speeds. To avoid 
personal injury, eye, hand and 
foot safety devices must be worn.

AVERTISSEMENT: Un jet haute 
pression peut écailler la peinture 
ou provoquer l'émission d'autres 

particules dans l'air et leur projection à hautes 
vitesses. Pour éviter les lésions corporelles, une 

protection des yeux, du visage, des mains et des 
pieds doit être portée lors de l'utilisation de cet 
équipement.

5. Always wear properly rated eye protection such as 

safety goggles or face shield while spraying. 

(Safety glasses do not provide full protection).

6. Keep operating area clear of all persons.

WARNING: Flammable liquids can create fumes 
which can ignite, causing property damage or 
severe injury.

AVERTISSEMENT: Des liquides inflammables 
peuvent produire des vapeurs qui peuvent 
s'enflammer, causant ainsi des dommages à la 
propriété ou des blessures graves.

WARNING: Risk of explosion — 
Operate only where open flame or 
torch is permitted.

AVERTISSEMENT: Risque d'explo-
sion- Utiliser uniquement dans 
des endroits où l'utilisation d'une 
flamme nue ou d'une torche est 
permise.

WARNING: Risk of fire — Do not 
add fuel when the product is 
operating or still hot. 

VERTISSEMENT: Risque 
d'incendie -Ne pas ajouter de 
carburant pendant que la machine 
fonctionner ou est encore chaude.

WARNING: Do not use gasoline 
crankcase draining or oil 
containing gasoline, solvents or 

alcohol. Doing so will result in fire and/or explo-
sion.

AVERTISSEMENT: Ne pas utiliser d'essence, de 
drainage du carter de moteur ou d'essence 
contenant de l'huile, de solvants ou de l'alcool. 
Agir de la sorte risquerait de créer un incendie et/
ou une explosion.

WARNING:   Risk of fire — Do Not spray flammable 
liquids. 

AVERTISSEMENT: Risque d'incendie - Ne pas 
pulvériser de liquides inflammables.

7. Allow engine to cool for 1-2 minutes before refu-

eling. If any fuel is spilled, make sure the area is 
dry before starting the engine. (Fire and/or 
explosion may occur if this is not done.)

Landa SLT/SLX Kubota Diesel Operator’s Manual  9.807-540.0 - E

WARNING

    READ OPERATOR’S 

 MANUAL THOROUGHLY 

           PRIOR TO USE.

OPERATIONS

SAFET

Y

MAINTENANCE

DANGER

       

KEEP WATER 

 SPRAY AWAY FROM 

ELECTRICAL WIRING.

WARNING

EAR PROTECTION

MUST BE WORN

WARNING

    USE PROTECTIVE 

  EYE WEAR 

AND CLOTHING

WHEN OPERATING

 THIS EQUIPMENT.

WARNING

RISK OF EXPLOSION: 

OPERATE ONLY WHERE 

OPEN FLAME OR TORCH 

IS PERMITTED

WARNING

RISK OF FIRE. 

DO NOT ADD FUEL 

WHEN OPERATING

MACHINE.

Summary of Contents for SLT Series

Page 1: ...E INDO ORS Asse mble d in USA Use Appro ved Deter gent Only Conta ins comp onent s from one or more of the follow ing count ries Unite d States China Italy Japan and Thaila nd 8 93 2 96 8 0 MODELS SL...

Page 2: ...tenance Glow Plug When the light is on the engine is being pre heated When the light turns off the engine can be started Low Oil When the light is on it means check the oil level Add oil if needed Bat...

Page 3: ...t Down And Clean Up 13 Maintenance Storage 14 Engine Maintenance 14 Maintenance And Service 14 Unloader Valves 15 Winterizing Procedure 15 High Limit Hot Water Thermostat 15 Pumps 15 Cleaning of Coils...

Page 4: ...e Levels of hazards are identified that could result in product damage personal injury or severe injury resulting in death The OPERATIONS section is to familiarize the operator with the operation and...

Page 5: ...guage by the purchaser owner making sure that the operator comprehends its contents Owner and or user must study and maintain for future reference the manufacturers instructions The operator must know...

Page 6: ...le spraying Safety glasses do not provide full protection 6 Keep operating area clear of all persons WARNING Flammable liquids can create fumes which can ignite causing property damage or severe injur...

Page 7: ...l shut off valve OFF CAUTION Hot discharge fluid Do not touch or direct discharge stream at persons or animals WARNING This machine produces hot water and must have insulated components attached to pr...

Page 8: ...tr me prudence au moment d utiliser une chelle des chafaudages ou toute autre surface relativement instable La zone de nettoyage doit avoir une pente et un drainage ad quats pour r duire la possibilit...

Page 9: ...ump damage 9 80 1 42 7 0 OF F GLST DO NOT OVE RLO AD GEN ERA TOR Units equip ped with optio nal gene rator shou ld not excee d 1000 watts resis tive load See Serv ice Manu al for detai ls CA UT IO N O...

Page 10: ...o insert your choice of pressure nozzle CAUTION Never replace nozzles without engaging the safety latch on the spray gun trigger ATTENTION Ne jamais remplacer les buses sans d abord mettre le disposit...

Page 11: ...807 540 0 E 9 8 01 427 0 OFF GL ST DO NO T OV ER LO AD GE NE RA TO R Unit s equ ippe d with opti ona l gen erat or sho uld not exce ed 100 0 wat ts resi stiv e load See Serv ice Man ual for deta ils...

Page 12: ...op Allow detergent to remain on surface 1 3 minutes Do not allow detergent to dry on surface If surface appears to be drying simply wet down surface with fresh water If needed use brush to remove stub...

Page 13: ...3 Turn engine key switch off Burner Switch 9 80 1 4 27 0 OF F GL ST DO NOT OVE RLO AD GEN ERA TOR Units equi pped with optio nal gene rator shou ld not exce ed 1000 watt s resis tive load See Serv ic...

Page 14: ...r 4 Cover the pressure washer and store in a clean dry place that is well ventilated away from open flame or sparks After Extended Storage CAUTION Prior to restarting thaw out any possible ice from pr...

Page 15: ...erating temperature the high limit control will turn the burner off until the water cools then automatically reset itself The thermostat sensor is located on the discharge side of the heating coil The...

Page 16: ...e located on the fuel pump to control the flow of fuel to the combus tion chamber The solenoid which is normally closed is activated by a flow switch when water flows through it When the operator rele...

Page 17: ...not to plug or enlarge the nozzle For maximum efficiency replace the nozzle each season Electrodes Setting SLT 6 8 only Burner Air Adjustment The oil burner on this machine is preset for operation at...

Page 18: ...om each side of coil and tank assembly these bolts are used to fasten tank to chassis 5 Remove fittings connected to the 1 2 pipe nipples from inlet and discharge sides of coil 6 Remove top tank wrap...

Page 19: ...ually Replace High Pressure Nozzle Every 6 months Replace Quick Connects Annually Clean Water Screen Filter Weekly Replace HP Hose Annually Kubota Engine Maintenance Schedule Engine Oil SAE 10W 30 API...

Page 20: ...foaming oil Engine Oil Check daily before first use of your new Power Washer Change pump oil after first 50 hours and every 200 hours thereafter Use SAE 10W 30 API CF rating Cj 4 DateOilChanged Month...

Page 21: ...n X X X Engine overload X X X X X X X Excessive parasitic load X X X Valve lash insufficient excessive X X X X Injection timing out of spec advanced X X X X X Injection timing out of spec retarded X X...

Page 22: ...pressure control valve Rebuild or replace as needed Slow engine RPM Set engine speed at proper specifications Pump sucking air Check water supply and possibility of air seepage Valves sticking Check...

Page 23: ...y Engine altitude The engine is preset for operation at altitudes below 1000 feet above sea level If operated at higher altitudes it may be necessary to contact your local authorized engine sales and...

Page 24: ...place Incorrect fuel nozzle size Contact your local Landa Dealer Insufficient water supplied Check water G P M to machine Restricted water flow Check nozzle for obstruction proper size PUMP NOISY Air...

Page 25: ...s Repair hole Low detergent level Add detergent if needed PUMP RUNNING NORMALLY BUT PRESSURE LOW ON INSTALLATION Pump sucking air Check water supply and possibility of air seepage Valves sticking Chec...

Page 26: ...9 807 540 0 Printed in U S A...