TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
BURNER WILL NOT
LIGHT cont.
Thermostat faulty or slow engine
speed
Increase engine RPM to increase
voltage.
Flow switch malfunction
Remove, test for continuity and replace
as needed.
Flow solenoid malfunction
Replace if needed.
MACHINE SMOKES
Improper fuel or water in fuel
Drain tank and replace contaminated
fuel.
Improper air adjustment
Readjust air bands on burner assembly.
Low fuel pressure
Adjust fuel pump pressure to
specifications. Call local Landa Dealer.
Plugged, dirty or faulty burner nozzle
causing incorrect spray pattern
Replace nozzle.
Heavy accumulation of soot on coils
and burner assembly
Remove coils and burner assembly,
clean thoroughly. Call local Landa
Dealer.
Misaligned electrode setting
Realign electrodes to specifications.
Obstruction in smoke stack
Check for insulation blockage or other
foreign objects.
Low engine RPM
Increase RPM. See serial plate for RPM.
BURNER MOTOR WILL
NOT RUN
Fuel pump seized
Replace fuel pump.
Burner fan loose or misaligned
Position correctly, tighten set screws.
Defective control switch
Replace switch.
Loose wire
Check and replace or tighten wiring.
Defective burner motor
Replace motor.
LOW WATER
TEMPERATURE
Improper fuel or water in fuel
Replace with clean and proper fuel.
Low fuel pressure
Increase fuel pressure.
Weak fuel pump
Check fuel pump pressure. Replace
pump if needed.
Fuel filter partially clogged
Replace as needed.
Soot buildup on coils not allowing
heat transfer
Clean coils. Call local Landa Dealer.
Improper burner nozzle
See breakdown for model.
WATER
TEMPERATURE
TOO HOT
Incoming water to machine warm or hot
Lower incoming water temperature.
Fuel pump pressure too high
Call local Landa Dealer for proper fuel
pressure.
Fuel pump defective
Replace fuel pump.
Detergent line sucking air
Tighten all clamps. Check detergent
lines for holes.
Defective high limit switch
Replace.
Incorrect fuel nozzle size
See breakdown for model.
Insufficient water supplied
Check water G.P.M. to machine.
Restricted water flow
Check serial plate for proper size.
(For parts and information call your Landa Dealer)