Chapter 4: Operation of Web- based Management
55
EN
once the power required by the PD excesses the Class, Short Circuit or
over temperature occurs.
쮿
Parameter Description:
왏
Status: Include “Normal” or “Active” two kinds of status. The former
means the port is ready to link and supply the power to the PD at any
time. The latter means the port is in the condition of supplying the
power.
왏
State: “Enable” means the manager allows the power supplied to the
PD is legal while the port linked to the PD; “Disable” means the port
does not own PoE function.
왏
Priority: Three options are offered for the user to choose, including
Normal, Low and High. Default is Normal. The switch will stop supp-
lying the power to the port based on the order of the priority
Low‡Normal‡High in case total power required by all PDs linked to
the switch excesses the power limit. As the ports have the same prio-
rity, then the switch will cease the power supplement from the port
with the highest port id (12‡1).
왏
Power(W): The power is consumed by the port.
왏
Current(mA): The current is supplied to the PD by the port.