(Continued from cover page)
WORKING PRESSURE
Minimum
30 psi (206.8 KPa)
Maximum
120 psi (827.4 KPa)
Maximum inlet pressure
80 psi (551.6 KPa)
(with boost pump)
OPERATING TEMPERATURE
Minimum
40°F (4.4°C)
Maximum
113°F (45°C)
FLOW RESTRICTOR RATIO (REJECT PRODUCT)
One (1) Membrane Unit
3:1
Two (2) Membrane Unit
2:1
Efficiency rating, as verified by testing in accordance with NSF/ANSI 58:
One Membrane
16.96%
Two Membrane
18.46%
Efficiency rating means the percentage of the influent water to the system that is available to the user as
reverse osmosis treated water under operating conditions that approximate typical daily usage.
NOTES:
This system conforms to NSF/ANSI 58 for the specific performance claims as verified and substantiated by test data.
*Testing was performed under standard laboratory conditions - actual performance may vary.
PERFORMANCE DATA
This system has been tested according to NSF/ANSI 58 for reduction of the substances listed
below. The concentration of the indicated substances in water entering the system was
reduced to a concentration less than or equal to the permissible limit for water leaving the
system, as specified in NSF/ANSI 58.
Substance
Influent Challenge
Maximum Permissible
concentration mg/L
Product Water
Concentration mg/L
Barium
10.0 + 10%
2.0
Chromium (hexavalent)
0.3 + 10%
0.1
Radium 226/228
25 pCi/L + 10%
5 pCi/L
Total Dissolved Solids (TDS)
750 + 40 mg/L
187
i
Substance
Influent Challenge
Reduction Requirement
Concentration
Cyst
Minimum 50,000/ml
99.95%