INSTALLATION INSTRUCTIONS
ESCORT II AND III JUICE DISPENSERS
ELECTRONIC ICE BANK CONTROL (EIBC)
RETROFIT KIT (PN 82-3049)
1. REMOVAL AND INSTALLATION INSTRUCTIONS
WARNING
DISCONNECT FROM POWER SOURCE BEFORE BEGINNING THIS PROCEDURE. WATER BATH
MUST BE DRAINED AND ICE BANK MUST BE COMPLETELY MELTED. DO NOT ATTEMPT TO
CHANGE PROBE WITH ICE BANK STILL FROZEN.
1.1
Remove two (2) screws retaining Rear Lid over Agitator Deck and remove Lid.
1.2
Disconnect leads from load side of Transformer and disconnect Agitator/IBC connector at top inside
corner of dispenser.
1.3
Remove two (2) screws retaining Agitator Deck and remove Agitator Deck. Take care not to
damage Agitator propeller during retrofit.
1.4
Remove cover from Ranco IBC.
1.5
Remove three (3) leads from Ranco Control, noting which lead goes to the Junction Box and which
lead goes to the Compressor (third lead goes to Agitator Motor). The lead going to the Compressor
is on Pin 1 of the Agitator/IBC connector and the lead going to the Junction Box is on Pin 3 (see
Figure 1A).
1.6
Remove the hole plug insulation around the Ranco probe capillary tube and remove the Ranco
Probe and Ranco Control Box from the Agitator Deck.
Save screws and insulation plug for
reinstallation.
DATE: 08/10/01
P.N.:
28-0502
6655 LANCER BLVD. • SAN ANTONIO, TEXAS 78219 USA • (210) 310-7000
FAX SALES
• NORTH AMERICA – 210-310-7245 • INTERNATIONAL SALES – 210-310-7242 • CUSTOMER SERVICE – 210-310-7242 •
• LATIN AMERICA – 210-524-9567 / 210-310-7245 • EUROPE – 32-2-755-2399 • PACIFIC – 61-8-8268-1978 •
FAX ENGINEERING: • 210-310-7096
"Lancer" is the registered trademark of Lancer • Copyright — 2001 by Lancer, all rights reserved.
Figure 1A