14

 

DO NOT PLUG UNIT INTO GROUNDED ELECTRICAL 
OUTLET AT THIS TIME. 

Make sure that all water lines 

are tight and unit is dry before making any electrical 
connections.

WARNING

11.  Connect each syrup line to appropriate syrup inlet in the 

front of the unit (see 

Plumbing Diagrams

 on the front of the 

unit or on pages 29-32 for reference). 

 

Drain line must be insulated with a closed cell  
insulation. Insulation must cover the entire length of 
the drain hose, including fittings. The drain should be 
installed in such a manner that water does not collect 
in sags or other low points, as condensation will form.

CAUTION

Pouring hot water down the drain may cause the drain 
tube to collapse. Allow only warm or cold water to  
enter the drain tube.

 

Pouring coffee, tea, or other  

similar substances down the drain may cause the 
drain tube to become clogged.

ATTENTION

 

If installing a 6-Valve unit, two of the syrup lines will be 
capped. DO NOT remove the caps from the two syrup 
lines. See plumbing diagram for reference.

ATTENTION

12.  Connect each syrup line to individual syrup pump outlet 

fitting.

13.  Install BIB connectors to the syrup supply line tubing.

16.  Install PVC drain fitting to back left ice bin drain line.

17.  Install drain lines to both front and back drain fittings then 

tee the two drain lines together at the back of the unit.

18.  Route tee’d drain hose to designated open type drain.

19.  Install power supply assembly to bottom plate of free  

standing conversion kit or under counter.

20.  Route the power supply cord to a grounded electrical outlet 

of the proper voltage and amperage rating.

A. Syrup Supply Line
B. BIB Connector
C. BIB Syrup Container

A

B

C

 

Use proper connector for syrup manufacturer.

ATTENTION

A. Syrup Supply Line
B. BIB Connector

A

B

15.  Install threaded drain fitting (PN: 01-1612), included in  

accessory kit, to front drain line.

14.  Attach BIB connectors on syrup supply line to BIB. Repeat 

for each syrup line/pump.  

Summary of Contents for 23300 Series

Page 1: ...sit lancerworldwide com or call Tech Support Warranty 800 729 1550 6655 Lancer Boulevard San Antonio TX 78219 custserv lancerworldwide com 2018 2020 2022 Lancer Corp Lancer PN 28 3007 Revision 00 4 06...

Page 2: ...ing the Note signal provides you with information that may help you more effectively perform the installation procedures within this manual Disregarding information will not cause damage or injury how...

Page 3: ...ith a light pungent odor High percentages of CO2 may displace oxygen in the blood Prolonged exposure to CO2 can be harmful Personnel exposed to high concentrations of CO2 gas will experience tremors w...

Page 4: ...dth 15 25 inches 387 mm Depth 23 25 inches 591 mm PLAIN WATER SUPPLY Min Flowing Pressure 40 PSI 0 276 MPA Max Flowing Pressure 80 PSI 0 552 MPA CARBON DIOXIDE CO2 SUPPLY Min Pressure 90 PSI 0 621 MPA...

Page 5: ...COUNTER CUTOUT Width 23 25 inches 591 mm Depth 23 25 inches 591 mm PLAIN WATER SUPPLY Min Flowing Pressure 40 psi 0 276 MPa Max Flowing Pressure 80 psi 0 552 MPa CARBON DIOXIDE CO2 SUPPLY Min Pressure...

Page 6: ...s 124 kg Ice Capacity 100 lbs 45 kg 10 valve Shipping 255 lbs 116 kg Operating with Ice 304 lbs 138 kg Ice Capacity 100 lbs 45 kg CARBON DIOXIDE CO2 SUPPLY Min Pressure 90 psi 0 621 MPa Max Pressure 1...

Page 7: ...PLY Min Flowing Pressure 40 PSI 0 276 MPA Max Flowing Pressure 80 PSI 0 552 MPA CARBON DIOXIDE CO2 SUPPLY Min Pressure 90 PSI 0 621 MPA Max Pressure 110 PSI 0 758 MPA FITTINGS Carbonated Water Inlet 3...

Page 8: ...y A B C D E F F F F F F G G G G G G I H J J K 105 65 CO2 Line Carb Water Line Electrical Drain Line Plain Water Line Syrup Line A Water Source B Water Booster C Floor Drain D Water Regulator E Remote...

Page 9: ...weight of an ice machine plus weight of ice if necessary Is dispenser located away from direct sunlight or overhead lighting TOOLS REQUIRED Oetiker Pliers Tubing Cutters Wrench Slotted Screwdriver Phi...

Page 10: ...ting 2 The selected location should be able to support the weight of the dispenser and ice after the counter cutout is made Total weight with ice for this unit could exceed 400 pounds 181 4 kg 3 If in...

Page 11: ...23 inches 58 42 cm below the counter including the shipping risers which Lancer recommends be left attached to the unit Should the dispenser ever require removal the shipping risers will protect the i...

Page 12: ...may cause the drain tube to become clogged ATTENTION 13 Attach BIB connectors on syrup supply line to BIB Repeat for each syrup line pump 16 Install drain lines to both front and back drain fittings t...

Page 13: ...Tubing B Soda Water Inlet 4 Route the soda and plain water lines through the shipping riser legs in the back of the unit 1 If using freestanding conversion kit install per kit instruc tions then inse...

Page 14: ...ing a 6 Valve unit two of the syrup lines will be capped DO NOT remove the caps from the two syrup lines See plumbing diagram for reference ATTENTION 12 Connect each syrup line to individual syrup pum...

Page 15: ...lator at syrup pumps 4 Turn the knob on the CO2 regulator at the source all the way to the left counterclockwise to close the regulator Repeat for CO2 regulator at the syrup pumps DO NOT TURN ON CO2 S...

Page 16: ...gas out 9 Plug in the remote carbonator 10 When carbonator stops activate each valve until the car bonator pump comes on Release the button allow carbon ator to fill and stop Repeat this process unti...

Page 17: ...Verify that the syrup level is even with the water level Use a screwdriver to adjust if needed 6 Remove syrup separator and reinstall nozzle Replace valve ID cover 7 Repeat steps 2 6 for each valve 11...

Page 18: ...tizing agent recommended in the instructions by the manufacturer shall comply with 40 CFR 180 940 The solution must provide 200 parts per million PPM chlorine e g Sodium Hypochlorite or bleach and a m...

Page 19: ...solution from the dispenser 10 Taste the drink to verify that there is no off taste If off taste is found flush syrup system again Following sanitation rinse with end use product until there is no aft...

Page 20: ...e pump 6 Remove kink or replace line 7 Repair or replace CO2 regulator as required Syrup only dispensed no water but CO2 gas dispensed with syrup 1 Improper water flow to dispenser 2 Carbonator pump m...

Page 21: ...shutoff fully 3 Remove soda flow control from valve and clean out any foreign material to ensure smooth spool movement Insufficient water flow plain water drinks 1 Insufficient incoming supply pressu...

Page 22: ...utlet line 2 Defective BIB pump 1 Replace line 2 Replace BIB pump BIB pump continues to operate when bag is empty 1 Leak in suction line 2 Leaking O ring on pump inlet fitting 3 Defective syrup BIB pu...

Page 23: ...2077 for 23300 Illuminated Marquee PN 85 2301 for 2200 PN 85 2302 for 2300 PN 85 2303 for 23300 Water Spigot for Ambient Temperature Water Kit PN 82 3801 for PN 82 3903 for 2300 High Performance 2200...

Page 24: ...e Drain Assembly 5 30 11742 Lid 6 05 1512 01 Drip Tray 7 23 1214 Cup Rest 8 30 7093 Splash Plate 9 30 11907 Ice Bin Cover 10 19 0397 03 LEV without mounting block 19 0434 03 LEV Self Serve Lever witho...

Page 25: ...0405 Hole Plug 3 4 Dia SS 11 23 0862 Wire Drain Assembly Ice Cooled 12 06 4044 Plumbing Diagram Label 2323 ICDI 8 Valve SP Item Part No Description 13 23 0797 03 Cup Rest Wide Sabre Tower 14 23 1131...

Page 26: ...26 01 17 11 12 02 13 14 03 05 04 06 07 08 09 10 19 15 16 18 20 Series 2300 High Performance Drop In...

Page 27: ...Right Tower Structure Assy 10V 82 0992 Accessory Kit 2323 ICDI 82 1600 Label Kit 8 LEV ICDI 3 1 1 3 08 0510 Drain Tube CP ICDI Insulated Item Part No Description 01 30 16124 02 Sliding Bin Cover 2323...

Page 28: ...d 5 05 1092 Drip Tray 6 23 1001 01 Cup Rest 7 30 5926 01 Splash Plate 8 51 6119 01 Ice Bin Cover 9 19 0397 03 LEV without mounting block 19 0434 03 LEV Self Serve Lever without mounting block 19 0435...

Page 29: ...29 2200 Standard Performance 5 Valve 6 Valve 3 1 2 2 1 2 2200 Standard Performance 6 Valve 3 2 1 Plumbing Diagrams...

Page 30: ...30 2300 6 Valve Standard Performance 2300 8 Valve Standard Performance 2300 10 Valve Standard Performance...

Page 31: ...31 2300 6 Valve High Performance Plumbing Diagram 2300 8 Valve High Performance Plumbing Diagram 2300 10 Valve High Performance Plumbing Diagram...

Page 32: ...32 2300 Standard Performance 6 Valve 2300 Standard Performance 8 Valve 9 10 9 10 1 2 3 4 5 6 7 8 9 10 2300 Standard Performance 10 Valve Tower Plumbing Diagrams...

Page 33: ...3 PCB 2 1 2M WHITE BLACK PRESSURE SWITCH CDA SOLENOID WHITE BLACK ICE COOLED UNIVERSAL WIRING DIAGRAM WITH BIN LID SWITCH Ice Cooled Universal Wiring Diagram without Bin Lid Switch 2F 2F 2F 2F 2F M F...

Page 34: ...591 mm 25 635 mm 15 1 4 387 mm 17 432 mm FRONT 23 1 4 591 mm 25 25 641 mm 23 1 4 591 mm 25 5 648 mm FRONT View Looking Down 30 1 4 768 mm 32 813 mm 23 1 4 591 mm 25 635 mm 2200 Cutout 2323 Cutout 302...

Reviews: