DRIVE CAP ASSEMBLY, MAIN PISTON AND REGENERANT PISTON

 (refer to pages 10 for diagrams)

:

The drive assembly must be removed to access the drive cap assembly. The drive cap assembly must be removed to 

access the piston(s). The drive cap assembly is threaded into the control valve body and seals with an o-ring. To remove 

the drive cap assembly use the special plastic service spanner wrench (see page 13) or insert a ¼” to ½” flat blade 

screwdriver into one of the slots around the top 2” of the drive cap assembly so it engages the notches molded into the 

drive back plate around the top 2” of the piston cavity. See figure below. The notches are visible through the holes. Lever 

the screwdriver so the drive cap assembly turns counter clockwise. Once loosened unscrew the drive cap assembly by 

hand and pull straight out.

The drive cap assembly contains the drive cap, the main drive gear, drive cap spline, piston rod and various other parts 

that should not be dissembled in the field. The only replaceable part on the drive cap assembly is the o-ring. Attached to 

the drive cap assembly is the main piston and a regenerant piston.
The regenerant piston (the small diameter one behind the main piston) is removed from the main piston by pressing 

sideways and unsnapping it from its latch. Chemically clean in dilute sodium bisulfite or vinegar, or replace the regenerant 

piston if needed. To remove the main piston fully extend the piston rod and then unsnap the main piston from its latch by 

pressing on the side with the number. Chemically clean in dilute sodium bisulfite or vinegar, or replace the main piston.

Reattach the main piston to the drive cap assembly. Reattach the regenerant piston (if needed) to the main piston. 

Reinsert the drive cap assembly and piston into the spacer stack assembly and hand tighten the drive cap assembly. 

Continue to tighten the drive cap assembly using a screwdriver as a ratchet until the black o-ring on the spacer stack 

assembly is no longer visible through the drain port. Excessive force can break the notches molded into the drive back 

plate. Make certain that the main drive gear still turns freely. The exact position of the piston is not important as long as 

the main drive gear turns freely.
Reattach the drive assembly to the control valve and connect all plugs. After completing any valve maintenance involving 

the drive assembly or the drive cap assembly and pistons, unplug power source jack from the printed circuit board (black 
wire) and plug back in or press and hold 

NEXT

 and 

REGEN

 buttons for 3 seconds.

This resets the electronics and establishes the service piston position. The display should flash the software version and 

then reset the valve to the service position.

REFILL FLOW CONTROL ASSEMBLY

 (refer to page 11 for diagrams)

:

To clean or replace the refill flow control, pull out the elbow-locking clip and then pull straight up on the elbow. Replace the 

elbow locking clip in the slot so that it is not misplaced. Twist to remove the white flow control retainer. The flow control 

can be removed by prying upward through the side slots of the retainer with a small flat blade screwdriver. 
Chemically clean the flow control or the white flow control retainer using dilute sodium bisulfite or vinegar. Do not use a 

wire brush. If necessary, replace the flow control, o-ring on the flow control retainer, or the o-ring on the elbow.
Reset the flow control so the rounded end is visible in the flow control. Reset the white flow control retainer by pushing the 

retainer into the elbow until the o-ring seats. Remove locking clip, push down on elbow to reset and insert locking clip. 

Do not use Vaseline, oils, or other unacceptable lubricants on o-rings. A silicone lubricant may be used on the o-ring on 

the elbow or the white retainer. 

Summary of Contents for PLATINUM LINE LES X Factor Series

Page 1: ...ratulations on purchasing your new Lancaster Water Conditioner This unit is designed to give you many years of trouble free service When installed in accordance with the following instructions and if...

Page 2: ...mily Size Number of people in family Total Gallons Per Day x Grains Per Gallon of hardness Total Grains per Day INSTALLATION DATE SERIAL NUMBER INSTALLER NAME PHONE ADDRESS TABLE OF CONTENTS Job Speci...

Page 3: ...for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after treatment GENERAL INSTALLATION AND SERVICE WARNINGS PRE INSTALLATION REVIEW WAT...

Page 4: ...rs are glass filled Noryl or equivalent and the nuts and caps are glass filled polypropylene All seals are self lubricating EPDM to help prevent valve seizing after long periods of non use Internal o...

Page 5: ...tion on the control valve The control valve has a standard refill elbow to which a 3 8 flexible tube can be connected see page 6 One polytube insert is shipped on the brine line elbow s locking clip R...

Page 6: ...VALVE BEFORE AERATION SYSTEM AERATION SYSTEM A HOT WATER THERMAL EXPANSION TANK IS REQUIRED ON THE COLD WATER INLET OF A WATER HEATER TO SERVICE A HOT WATER THERMAL EXPANSION TANK IS REQUIRED ON THE C...

Page 7: ...to finish the RINSE cycle It will then advance to the FILL position The brine tank will now automatically fill with the proper volume of water for the first regeneration Allow the control to automati...

Page 8: ...y Override using or buttons number of days between regeneration 1 to 28 or OFF Press NEXT to go to step 4 Press REGEN to return to previous step STEP 4 Next Regeneration Time hour Set the hour of day...

Page 9: ...BUT AFTER ANY UNTREATED LINES AT LEAST 12 VERTICAL COLUMN OF WATER PIPE ON TOP OF CHECK VALVE BEFORE AERATION SYSTEM AERATION SYSTEM WELL PUMP SYSTEM SUPPLY GPM MUST EQUAL OR EXCEED AERATION SYSTEM S...

Page 10: ...10 1F Injector Assy F Blue 5 1 V3010 1G Injector Assy G Yellow Not Shown V3170 O Ring 011 Not Shown V3171 O Ring 013 Injector plug and injector each contain one 011 and one 013 O Ring Refer to page 17...

Page 11: ...Description Qty 1 V3151 Nut 1 QC 1 2 V3003 Meter Assy 1 3 V3118 01 Turbine Assy 1 4 V3105 0 ring 215 1 Order number V3003 includes V3118 01 Turbine Assy and V3105 O ring 215 REFILLFLOWCONTROLASSEMBLY...

Page 12: ...wing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3191 Vertical Adapter 2 INSTALLATION FITTING ASSEMBLIES 4 Water Flow Proper DLFC orient...

Page 13: ...r 2 8 V3152 O ring 135 2 9 V3155 O ring 112 2 10 V3156 O ring 214 2 BYPASS VALVE Order No V3193 Although no tools are necessary to assemble or disassemble the valve the wrench shown in various positio...

Page 14: ...Ring 2 3 V3105 O Ring 215 2 4 V3375 Fitting 1 1 Brass Sweat 2 Order No V3007 07 Description Fitting 1 1 PVC Solvent Assembly Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V...

Page 15: ...re not fully engaged the piston rod is not in hole the wires are jammed between the drive bracket and drive back plate or the gear is not engaging the drive cap assembly To inspect the drive gears the...

Page 16: ...bly and hand tighten the drive cap assembly Continue to tighten the drive cap assembly using a screwdriver as a ratchet until the black o ring on the spacer stack assembly is no longer visible through...

Page 17: ...used Sharp objects which can score the plastic should not be used to clean the injector Scoring the injector or increasing the diameter of the hole could change the operating parameters of the inject...

Page 18: ...iston not in home position d Press NEXT and REGEN for 3 seconds or unplug power source jack black wire and plug back in to reset control valve e Motor not inserted fully to engage pinion motor wires b...

Page 19: ...PAGE 19 NOTES...

Page 20: ...PAGE 20 A DIVISION OF C B TOOL CO 1340 MANHEIM PIKE LANCASTER PA 17601 3196 TEL 717 397 3521 FAX 717 392 0266 www lancasterwatertreatment com E mail info lancasterpump com 11 19...

Reviews: