![Lancaster LRO-35 Installation, Operation And Service Manual Download Page 11](http://html1.mh-extra.com/html/lancaster/lro-35/lro-35_installation-operation-and-service-manual_672557011.webp)
11
•Turn the handle to expose the lance no more
than
3
/
16
" beyond the rubber gasket.
•Place the body of the valve over the hole so
that the lance fits into the hole.
•Assemble and tighten the brass screw.
•Turn the Valve Handle clockwise (inward)
until firmly seated. The valve is closed.
3. With the Feed Water Saddle Valve closed,
open the sink faucet and the water supply
and allow the water to run for a few minutes
to flush any debris caused by the installation.
•Close the faucet and check the Feed Water
Saddle Valve for leaks.
FEED WATER SADDLE VALVE
Cold Water
Line
Saddle
Valve
Handle
Insert
Plastic
Ferrule
Red Tubing To
Manifold
Inlet
Compression
Nut
Tightening
Screw
Reversible
Back Plate
Figure 3
C. Drain Clamp Installation
Choose the drain outlet location per Sec. III, C.5,
page 8.
The following are instructions for discharging into
the sink drain pipe. (Refer to Fig. 1, page 5.)
1. Position the Drain Clamp on the sink drain
pipe above the drain trap. Allow room for
drilling. Tighten securely.
2. Use a battery powered or properly grounded
drill. Using the Clamp port as a drill guide,
drill a
7
/
32
" hole through the wall of the drain
pipe. Do NOT penetrate the opposite side of
the pipe.
3. Locate the
3
/
8
" Black Drain Tubing connected
to the Dispensing Faucet. Route to the tubing
to the Drain Clamp and trim to length.
NOTE:
When cutting the polytubing make
clean, square cuts, failing to do so could
result in poor connections and possible leaks.
CAUTION:
The lowest point of the line
should be the point of connection to the Drain
Clamp. There should be no sag in the line as
this may cause excessive noise as the reject
water is flowing to drain.
•Refer to Fig. 4, page 12. Insert the tubing
into the Drain Clamp. Make sure the
tubing is pressed all the way in to create a
pressure tight connection.
NOTE: If you want to pull the tubing out for
some reason, push the ring around the
tubing in and pull the tubing out.
D. R.O. Manifold Assembly Installation
Locate the site per Sec. III, C.3, page 7. Various
installation sites will require different types
of mounting fasteners; be sure the fastener
selected will provide a firm, solid mounting.
A support panel may be necessary on thin
cabinet walls or to span between wall studs on
particleboard or drywall.
Do not drill through exterior cabinet walls or
leave sharp wood screw points exposed in
readily accessible cabinet interiors.
The close proximity of a dishwasher or a trash