Lancaster 7-LXDAN-1 Installation, Operating And Service Manual Download Page 12

PAGE 12

Drawing No.

Order No.

Description

Qty

1

V3176

INJECTOR CAP

1

2

V3152

O-RING 135

1

3

V3177-01

INJECTOR SCREEN CAGE

1

4

V3010-1Z

INJECTOR ASSY Z PLUG

1

5

V3010-1C INJECTOR ASSY C VIOLET

1

V3010-1F

INJECTOR ASSY F BLUE

V3010-1H  INJECTOR ASSY H GREEN

Not Shown

V3170

O-RING 011

*

Not Shown

V3171

O-RING 013

*

* The injector plug and the injector each contain one 011 (lower) and 013 (upper) 

o-ring.

Only used with 7-LXCTAIR and 7-LXIMAIR Models. For all other models, a second 

V3010-1Z injector assy Z plug is used.

The nut and caps are designed to be unscrewed or tightened by hand or with 

the service spanner wrench (see page 16). If necessary a pliers can be used to 

unscrew the nut or cap. Do not use a pipe wrench to tighten or loosen nuts or caps. 

Do not place a screwdriver in slots on caps and/or tap with a hammer.

Refer to page 20 for detailed service instructions.

1

2

3

4

5

INJECTOR CAP, INJECTOR SCREEN, INJEECTOR, PLUG AND O-RING

Drawing 

No.

Order No.

Description

Qty

1

V3005

Spacer Stack Assembly

1

2

V3004

Drive Cap Assy

1

3

V3178LP

Back Plate

1

4

V3011

Piston Downflow Assy

1

5*

V3174

Regenerant Piston

1

6

V3135

O-ring 228

1

7

V3180

O-ring 337

1

8

V3105

O-ring 215 (Distributor Tube)

1

Not Shown

V3001

Body Assy Downflow 

1

*Only used with 7-LXCTAIR and 7-LXIMAIR models.

DRIVE CAP ASSEMBLY, DOWNFLOW PISTON, 

REGENERANT PISTON AND SPACER STACK ASSEMBLY

After completing any valve 

maintenance involving the drive 

assembly or the drive cap assembly 

and pistons, unplug power source jack 

from the printed circuit board (black 

wire) and plug back in or press and 
hold 

NEXT

 and 

REGEN

 buttons for 3 

seconds. This resets the electronics 

and establishes the service piston 

position. The display should flash the 

software version and then reset the 

valve to the service position.

Refer to pages 18-20 for detailed 

service instructions.

Do not use Vaseline, oils, other hydrocarbon lubricants 

or spray silicone anywhere. A silicone lubricant may be 

used on black o-rings but is not necessary.

 Avoid any 

type of lubricants, including silicone, on the clear 

lip seals. 

2

6

4

1

3

7

8

5

*

Summary of Contents for 7-LXDAN-1

Page 1: ...inspection purposes please file this booklet with your important documents ELECTRONIC WATER FILTER WITH THE X FACTOR CONTROL VALVE INSTALLATION OPERATING AND SERVICE MANUAL WATER FILTERS AND NEUTRALI...

Page 2: ...Instructions for 7 LXCTAIR 7 LXIMAIR 7 Placing Filter into Service 8 General Operation 8 Set Time of Day 9 Adjust Days Between Backwash or Time of Backwash 9 10 Low Battery 10 Contact Screen Programm...

Page 3: ...damage the nut split ring or o ring Solder joints should be cool and solvent cements should be set before installing the nut split ring and o ring Avoid getting primer and solvent cement on any part...

Page 4: ...lass filled Noryl or equivalent and the nuts and caps are glass filled polypropylene All seals are self lubricating EPDM to help prevent valve seizing after long periods of non use Internal o rings ca...

Page 5: ...4 When assembling the installation fitting package inlet and outlet connect the fitting to the plumbing system first and then attach the nut split ring and o ring Heat from soldering or solvent cement...

Page 6: ...HOT LOCATE WATER FILTER CLOSE TO A DRAIN AVOID OVERHEAD DRAIN LINES IF POSSIBLE TO PREVENT BACK PRESSURE ON THE SYSTEM IF OVERHEAD DRAIN LINE IS USED AND EXCEEDS 5 FEET ABOVE CONNECTION ON CONTROL VAL...

Page 7: ...NE AFTER THE AERATION SYSTEM BACKWASHES A SPUTTERING OF AIR MAY BE NOTICED AT THE FIRST WATER FIXTURE TO BE USED AFTER THE SYSTEM BACKWASHES IF THIS IS OBJECTIONABLE A CHECK VALVE CAN BE INSTALLED DIR...

Page 8: ...an air pocket to form for the filter to function properly Control will automatically advance to the FILTERING position Open the outlet valve of the filter or if using optional bypass place to NORMAL...

Page 9: ...and simultaneously for 3 seconds to access Installer Display Settings STEP 2 Day Override Set the maximum number of days between backwashes REGEN If value set to OFF backwash initiation is based solel...

Page 10: ...digit Banner Text Set the banner text up to a maximum of 44 characters Use the or to select letters of the alphabet numbers ampersand or a space in the banner text Press NEXT to forward to the next ch...

Page 11: ...sh down to fully seat Battery replacement is 3 volt lithium coin cell type 2032 Correct Battery Orientation 1 2 3 5 6 4 X FACTOR FRONT COVER AND DRIVE ASSEMBLY After completing any valve maintenance i...

Page 12: ...Drawing No Order No Description Qty 1 V3005 Spacer Stack Assembly 1 2 V3004 Drive Cap Assy 1 3 V3178LP Back Plate 1 4 V3011 Piston Downflow Assy 1 5 V3174 Regenerant Piston 1 6 V3135 O ring 228 1 7 V3...

Page 13: ...tightened by hand or with the service spanner wrench see page 16 If necessary a pliers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten or loosen nuts or caps Do not place a...

Page 14: ...dge Do not use pipe dope or other sealants on threads Teflon tape must be used on threads of 3 4 NPT connection unless using 5 8 polytubing Do not use Vaseline oils other hydrocarbon lubricants or spr...

Page 15: ...g Vertical Adapter Assembly Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3191 Vertical Adapter 2 INSTALLATION FITTING ASSEMBLIES...

Page 16: ...tools are necessary to assemble or disassemble the valve the wrench shown in various positions on the valve may be purchased to aid in assembly or disassembly Loosens Injector And Bypass Caps Loosens...

Page 17: ...antity of 24 Order No V3007 09 Description Fitting 1 1 Brass Sweat Assembly Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3375 Fit...

Page 18: ...cally depending on local conditions Pressure drop is very low DRIVE ASSEMBLY refer to pages 11 12 for diagrams Remove the valve cover to access the drive assembly Disconnect the power source plug blac...

Page 19: ...seals with an o ring To remove the drive cap assembly use the special plastic service spanner wrench see page 16 or insert a to flat blade screwdriver into one of the slots around the top 2 of the dr...

Page 20: ...iers if necessary Attached to the injector cap is a screen Remove the screen and clean if fouled The plug and or injector can be pried out with a small screwdriver The plug can be wiped clean If the p...

Page 21: ...lace meter f Defective PC Board f Replace PC Board 4 Control valve backwashes at wrong time of day a Power outage a Reset time of day If PC Board has battery back up present the battery may be deplete...

Page 22: ...tion or disconnect power supply from PC Board for 5 seconds and then reconnect b PC Board not properly snapped into drive bracket b Properly snap PC Board into drive bracket and then Press NEXT and RE...

Page 23: ...NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect Then re program valve to proper setting b...

Page 24: ...PAGE 24 A DIVISION OF C B TOOL CO 1340 MANHEIM PIKE LANCASTER PA 17601 3196 TEL 717 397 3521 FAX 717 392 0266 www lancasterwatertreatment com E mail info lancasterpump com 8 12...