5.
Strobe and Navigation Light Circuit Breakers – OUT
6.
Pitot Heat Circuit Breakers – OUT
7.
Master Switch – ON (if necessary)
8.
Put the aircraft on the ground immediately. Land As Soon As Possible.
ELECTRICAL FIRE
Circuit breakers protect most electrical circuits and automatically interrupt power
to prevent a fire when a short occurs. If necessary, however, turn MASTER
Power Switch OFF to remove power from all electrical equipment, and land as
soon as possible. If electrical power is essential, as during an instrument flight,
an attempt to identify and isolate the defective system may be possible.
SMOKE/FUMES ELIMINATION
Should smoke or fumes enter the cockpit, proceed as follows:
If originating in cabin:
1.
Cockpit Air Control – OPEN
2.
Air Outlets – OPEN
3.
Windshield and canopy defrost control handle – ON
5. Deflate the door seal
6. O2 mask on --check O2 flow “ON”
If oil/exhaust smell:
1.
Air to pressurization – CLOSE
2.
Pressurization dump switch – OPEN
3.
Deflate the door seal
4.
O2 mask on --check O2 flow “ON”
TURBOCHARGER FAILURE
‐