Your purchase and use of SR-1006 gas alarm is much appreciated. Please read these 
instructions BEFORE using the device, and make sure to keep this manual after carefully 
reading it, for the future reference.

1. Summary

The household gas alarm has been developed by adopting advanced electronic and gas 
detecting techniques. It is highly sensitive and is applicable to detect the leakage of 
household gasses, liquid gasses and natural gas. The sensor reacts with the diffused 
gases in the air directly and generates a linear voltage signal. When the detected gas 
density reaches a specific value, the alarm emits an acousto-optic alarm signal to remind 
its users to take appropriate measures in time. SR-1006 gas alarm has a modern, smart 
design, and is convenient to use.

2. Technical Parameter

• Rated voltage: AC230 V/50~60 HZ
• Power dissipation: <1,9 W
• Battery: 9 V accumulator (optional)
• Operating temperature: 0°C ~ + 50°C
• Operating humidity: 10%~95% RH
• Alarming level of gas density: 2500 PPM (+/- 1500 PPM)
• Alarm loudness / effective range: ≥85 dB @ 1 m
• Dimensions:  112 x 73 x 42 mm

3. Operation

A) Plug in the gas alarm to mains, so that it can preheat (for about 2 minutes), with red 
indicator light being turned on. During this time, the gas alarm does not detect gas. 
After the device finishes preheating, the red indicator light will turn off. That is a sign 
that shows the detector is in a testing mode (it may emit alarms when being plugged 
into mains, and will switch to normal operating mode after preheating, a few minutes 
later.)
B) Testing mode: Press the test button for a few seconds, the red indicator light will 
start to flash, and the gas alarm will emit sounds. That means the detector is working 
well. Install the gas alarm in the desired place (after testing it) and plug it into the 
power supply accordingly.
C) In case of events, the alarm has tested the corresponding density of the gas, the 
red indicator light will flash and emit sound alarms. That reminds the users to take 
appropriate measures in time.
D) Press the test button with regular intervals, to make sure the alarm is in normal 
operating mode and make sure to keep the surrounding area clean.
WARNING: If the yellow LED on the device is continuously lit, it means that the 
detector's sensor has been damaged, and it no longer performs its functions - THE 
SENSOR'S LIFECYCLE LASTS 
ABOUT 5 YEARS.
OPTIONAL: The device can be fitted with a 9 V battery (6F22), which allows 
uninterrupted operation of the device, even in case of power failure. The 200 mAh 
battery allows the device to work for about 3 hours. (Battery not included.) 

4. Installation

A) If this particular device is used to detect natural gas, please install the alarm in place 
at least 50 centimeters away from the ceiling, as well as, within 1,5m distance from the 
nature gas source. The main component of natural gas is methane, which is lighter than 
air, therefore the gas alarm should be mounted on the walls should not be placed below 
the top frame of doors or windows.

B) If this particular device is used to detect compressed petroleum gasses or city coal 
gasses, their main components are propane or butane, which are heavier than air, hence 
the alarm should be mounted in lower places, generally installed at a distance of less 
than 30 cm from the ground and within a distance of 1.5m away from the LPG source. 
On top of that, there should be no doors or windows located, between the alarm and 
LPG source, because that prevents the leakage of the gas, from reaching the alarm for 
the first time.

Gas alarm CANNOT be installed in the following places:

A) Do NOT install the alarm at the top of the cooker (similar kitchen appliances), as 
smoke, fat and /or dirt may negatively affect alarm’s functionality.

B) Do NOT install the alarm above the sinks (or any water containers), as water splashes 
(humidity) and /or dust may negatively affect alarm’s functionality.

C) Do NOT install the alarm in places, where there are air / vent holes, fans or any other 
ventilated places nearby. This may prevent the leakage of gas from reaching the alarm 
for first time.

D) Do NOT install the alarm in tightly-covered concealed places. This may delay the 
proper detection of gas leakage.

E) Do NOT install the alarm outdoors or in places with humidity being lower than 10% 
or higher than 95%.

5. Warning

A) Do use special fittings for any possible repairs, to avoid damaging the product.
B)  Do  not  repair  the  gas  alarm  by  yourself.  Let  the  professionals  handle  the 
maintenance.
C) Make sure to keep the household gas alarm and its packaging materials, out of reach 
of the children.
D) The product warranty does not cover any improper use or human-made damage.

6. Warranty

The product is covered by 24-month warranty.

EN

PL

Summary of Contents for SR-1006

Page 1: ...SR 1006 ELECTROCHEMICAL GAS ALARM ELEKTROCHEMICZNY CZUJNIK GAZU USER MANUAL INSTRUKCJA OBSŁUGI ...

Page 2: ...k 3 min Zostanie wydany pojedynczy sygnał dźwiękowy i czerwona lampka oznaczona ALARM będzie mrugać wskazując działanie czujnika w trybie uruchamiania Przez ten okres czasu czujnik nie będzie w stanie wykryć gazu Po nagrzaniu czerwona lampka na urządzeniu zgaśnie w jej miejsce zapali się lampka zielona oznaczona POWER sygnalizując iż czujnik działa w trybie normalnym B Stan testowy urządzenia Wciś...

Page 3: ...LPG Należy pamiętać o tym aby pomiędzy umieszczonym alarmem gazowym a miejscem wycieku gazu nie znajdowały się drzwi lub okno dokładne i precyzyjne wykrywanie gazu nie będzie wtedy możliwe Nie wolno montować urządzenia w miejscach A Nad kuchenką gazową dym tłuszcz oraz brud mogą zakłócić prawidłową pracę urządzenia B Nad zlewami rozbryzgi wody również wilgoć oraz kurz mogą wpłynąć negatywnie na po...

Page 4: ...ght being turned on During this time the gas alarm does not detect gas After the device finishes preheating the red indicator light will turn off That is a sign that shows the detector is in a testing mode it may emit alarms when being plugged into mains and will switch to normal operating mode after preheating a few minutes later B Testing mode Press the test button for a few seconds the red indica...

Page 5: ...talled in the following places A Do NOT install the alarm at the top of the cooker similar kitchen appliances as smoke fat and or dirt may negatively affect alarm s functionality B Do NOT install the alarm above the sinks or any water containers as water splashes humidity and or dust may negatively affect alarm s functionality C Do NOT install the alarm in places where there are air vent holes fans ...

Page 6: ...e contact your retailer or a local authority Użycie symbolu WEEE przekreślony kosz oznacza że niniejszy produkt nie może być traktowany jako odpad domowy Prawidłowa utylizacja zużytego sprzętu pozwala uniknąć zagrożeń dla zdrowia ludzi i środowiska naturalnego wynikających z możliwej obecności w sprzęcie niebezpiecznych substancji mieszanin oraz części składowych a także niewłaściwego składowania ...

Reviews: