19
Call 1-888-370-6531 for Technical Support
6.3 Maintenance Procedures
The following sections provide detail on how to perform the recommended maintenance. If
you have questions or need assistance, contact Technical Support.
Inspect
compressor
and replace
air filter
annually
Remove ash
every 1000
hours or at
the end of
every heating
season.
Inspect preheater
annually. Clean
grooves and
replace gasket
when needed.
Inspect
electrode
and retention
head settings
annually
(Sect. 6.4.5)
Clean / inspect
solenoid valve
and replace O-
rings annually.
Clean / inspect
nozzle and flame
retention head
annually and
replace nozzle or
O-ring when
needed.
Clean fan
annually.
Clean fuel-fill
filter basket
annually or
as needed.
Drain water from tank as
needed. Clean tank as
needed. Inspect monthly.
Always wear personal protective equipment when performing inspection and
service. The maintenance schedule is the minimum recommended, but if you see smoke or
have trip outs then the unit must be shut down and serviced immediately before running it
again. Increase the maintenance as your situation requires.
Summary of Contents for MX 75
Page 2: ......
Page 41: ...8 Appendices 8 1 Wiring Diagram ...
Page 42: ......
Page 43: ...34 Call 1 888 370 6531 for Technical Support 8 2 Primary Control Instructions ...
Page 44: ...35 Call 1 888 370 6531 for Technical Support Not used with RES 75 kBTU h units ...
Page 45: ...36 Call 1 888 370 6531 for Technical Support No latch up with RES 75 kBTU h units ...
Page 46: ...37 Call 1 888 370 6531 for Technical Support ...
Page 54: ...45 Call 1 888 370 6531 for Technical Support 9 ...