25
ELECTRONICAL CONTROLLER
PLEASE NOTE:
THE IMPULSE NUMBER AUTO-
CALIBRATION MODE IS MORE ACCURATE AND
A FIELD TEST PERFORMANCE IS REQUIRED.
Auto-calibrating the speed sensor
1-
Mark 100 metres.
2-
Select channel 1 (speed).
3-
Press
and hold it while pressing
.
The screen will display “Auto”. Release it.
4-
Cover the 100 marked metres. The monitor will count the
sensor’s impulses.
5-
After finishing, press
again.
By doing this, the monitor retains the impulse number in
the memory.
10.3 TOTAL AREA /
SEED DRILL WIDTH – C2
Two independent total areas can be marked.
Displaying the total area
1-
Select channel 2.
2-
Press
to display total areas 1 and 2 on the screen.
First, “tot. 1” will be displayed and immediately afterwards
the value in Ha will be shown.
Setting to zero the total areas
1-
Select channel 2.
2-
Press
to display.
3-
Press and hold
for more than 5 seconds..
Programming the working width
1-
Select channel 2 of the area.
2-
Press and hold
for more than 5 seconds until the
width value is displayed and, without releasing it, press
the central button to modify the flickering digit.
3-
Press and hold the flickering digit for more than 5 se-
conds to modify its value.
4-
Release all buttons to return to the normal state.
Working in micro mode
When working with the distributor in the micro-dosing
mode (for small hoppers and minimal doses), press and hold
button for more than 3 seconds until the arrow indica-
ting the micro mode is displayed. In this situation, the moni-
tor will keep the speed and actual real working area.
Press and hold
for more than 5 seconds until the indi-
cating arrow disappears to resume normal position.
10.4 FRONT PANEL WITH MARKER PATHS
(OPTIONAL)
Fig. 34
The monitor provided comes programmed especially for
your model of seed drill. The user will only need to observe
the displayed values and no extra programming is required.
The monitor shows 6 different channels or readings, as well
as 3 different arrows showing the states.
C1
shows forward speed in m/sec.
C2
shows two different hectares (for example on partial
and one total hectare).
C3
tramlining.
C4
shows the fan’s rpm.
C5
shows the turning speed of the distributor’s axle’s in
rpm.
C6
shows if the hopper’s seed level is too low.