TECHNICAL SPECIFICATIONS
100%
GEOTHERMAL HEAT
HEAT COLLECTION CIRCUIT(S):
Esi 6
Esi 9
Esi 11
Esi 11
1x230V
Esi 14
Esi 14
1x230V
Esi 17
Emi 22(22P) Emi 28 (28P) Emi 43 (43P) ELi 60 (60P) ELi 90 (90P)
Energy class of brine pump
A (inverter) A (inverter) A (inverter) A (inverter) A (inverter) A (inverter) A (inverter) A (inverter) A (inverter) A (inverter) A (inverter) A (inverter)
Input power of brine pump
W
5-89
5-89
10-170
10-170
10-170
10-170
10-170
160-1330
160-1330
160-1330
30-2100
Factory setting of brine pump
%
90
90
90
90
90
90
90
90
90
90
90
100
Ground loop maximum
length, 1 ground loop
(6
Borehole,
PEH, PN6
m
500
350
450
500
-
-
-
-
-
-
-
-
Horizontal pipe,
PEM, PN10
m
450
300
-
380
-
-
-
-
-
-
-
-
Ground loop maximum
length, 2 ground loops
(6
Borehole,
PEH, PN6
m
-
900
1200
1600
900
1000
600
1050
-
-
-
-
Horizontal pipe,
PEM, PN10
m
-
750
1050
1250
650
800
500
900
-
-
-
-
Ground loop maximum
length, 3 ground loop
(6
Borehole,
PEH, PN6
m
-
-
-
-
-
-
-
-
700
-
500
-
Horizontal pipe,
PEM, PN10
m
-
-
-
-
-
-
-
-
550
-
400
-
Ground loop maximum
length, 4 ground loop
(6
Borehole,
PEH, PN6
m
-
-
-
-
-
-
-
-
-
750
900
-
Horizontal pipe,
PEM, PN10
m
-
-
-
-
-
-
-
-
-
600
700
-
Nominal flow
∆T=3K (ISO
14511)
l/s
0,64
0,79
0,94
0,91
1,18
1,11
1,34
1,65
2,19
3,41
-
700
Maximum external
pressure drop
kPa
53
48
81
82
65
71
54
203
89***
127
-
550
Nominal flow
∆T=4K
l/s
0,48
0,59
0,70
0,68
0,89
0,83
1,00
1,24
1,64
2,56
-
900
Maximum external
pressure drop
kPa
66
65
96
100
84
91
77
208
100***
152
-
750
HEAT DISTRIBUTION CIRCUIT:
Energy class of HC pump
A (inverter) A (inverter) A (inverter) A (inverter) A (inverter) A (inverter) A (inverter)
Accessory
Input power of HC pump
W
5-53
5-53
5-53
5-53
5-53
5-53
5-53
Nominal flow
∆T=5K Floor
heating
l/s
0,40
0,50
0,59
0,58
0,74
0,71
0,70**
Maximum external
pressure drop
kPa
51
42
29
30
15
18
19**
Nominal flow
∆T=10K Ra
-
diator heating
l/s
0,18
0,23
0,27
0,27
0,34
0,33
0,40
Maximum external
pressure drop
kPa
71
69
66
66
57
60
51
*Meets the energy efficiency class A+++ requirements. Meets the domestic hot water energy efficiency class A+ requirements.
**Calculated according to nominal flow at ∆T=7K.
***Maximum external pressure drop is possible to raise 191 kPa ∆T3, (204 ∆T4) when using 35 A fuses. Contact to your local dealer.
1) Tested according to ISO 3744/2010 at standard point B0/W55.
2) Tested according to ISO 14511/2013.
3) Tested according to EU 811/2013 at colder climate conditions.
4) Package means the combination of heat pump and heating regulator (EU 811/2013).
5) If conditions are requiring long cable work it is recommended to use 5x6 mm2 cable.
6) Calculated length according to nominal flow at ∆T=4K. Actual pressure drop is determined case by case.
8. ENERGY LABEL
9. HVAC SCHEMES
10. ELECTRICITY SCHEMES
Summary of Contents for ESI 6-17
Page 35: ...A A 55 C 35 C 60 dB 00 dB 58 58 58 kW 61 61 61 kW 2015 811 2013 ELi 60 A A A B C D E F G...
Page 36: ...A A A A A B C D E F G A 2015 811 2013 X ELi 60...
Page 39: ...A A 55 C 35 C 60 dB 00 dB 58 58 58 kW 61 61 61 kW 2015 811 2013 ELi 60P A A A B C D E F G...
Page 40: ...A A A A A B C D E F G A 2015 811 2013 X ELi 60P...
Page 43: ......
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ......
Page 48: ......
Page 49: ......
Page 50: ......
Page 51: ......
Page 52: ......
Page 53: ......
Page 54: ......
Page 55: ......
Page 56: ......
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ......
Page 61: ......