WWW.LAMPOLIGHTING.COM
made in P.R.C.
SENSPIRBI
OPERATION INSTRUCTION AND INSTALLATION
INSTALLATION
FUNCTIONS
SAFETY
IMPORTED BY: LAMPO LIGHTING TECHNOLOGY SRL
Via dell’industria 6, 47832 San Clemente RN ( ITALY )
www.lampolighting.com
• Time setting (TIME) for switching on, from 10 seconds to 8 minutes
• Light sensitivity adjustment (LUX), from a minimum of 3 lux to a ma-
ximum of 2000 LUX. Set the controller to maximum to use the sensor
during daylight hours
~ IN
fig.1
fig.2
LOAD
L (BROWN)
N (BLUE)
A (RED)
ENG
•
Installation and maintenance must only be carried out by qualified personnel
•
Always switch off the voltage before installing or servicing
•
Place the product in a suitable place for protection class IP54
•
Do not disassemble or tamper the product to avoid electrical shocks
•
Do not install on an unstable surface
The SENSPIRBI model is a switch with an infrared sensor that detects movement within its range (180 °)
at a distance of max 12mt.
Cod.
Input
Power load
Detection range
Time
Installation
IP
SENSPIRBI
AC220-240VAC 50Hz
LED 200W, INC 800W
max 12 mt 180°
10 Sec - 8 Min
H: 1.8 - 2.5mt
54
This instruction sheet have to be kept for future consultations
1.
Switch off main power
2. Unscrew the screw on the lower cover, pass the tension and load cables through the two cable glands
(see fig.1)
3.
Drill the holes in the designated place and fix the cover to the wall
4.
Make the connections of the voltage and load cable to the terminals, as shown in fig.2
5.
Mount the sensor to the cover and fix with the screw
6. Switch on main power and test the sensor