FLOODLIGHT SERIE
FLOODLIGHT LED INSTRUCTIONS
SAFETY
INSTALLATION
•
Installation and maintenance must only be performed by qualified personnel.
•
Respect IP65 protection: the headlamp can not be immersed in water.
•
If the glass breaks, replace it immediately with a tempered glass.
•
Always switch off the power before installing or servicing.
•
Do not disassemble or tamper with the product to avoid electrical shocks.
•
Connect the floodlight to the ground.
•
Keep this instruction sheet.
1. Turn off the power
2. Do not mount the floodlight on surfaces subject to vibration.
3. Remove the bracket from the floodlight removing the appropriate screws (see fig.1).
4. Use the bracket to mark the holes to be made on the wall. Drill the wall in the marked
positions. Fix the bracket to the wall with suitable screws (not included) (see fig.2).
5. Mount the bracket to the floodlight , adjust the desired inclination and tighten the bolts (see fig.3).
6. Connect the mains cables to the floodlight cables keeping the IP65 protection with ≥IP65
connector (not included)
7. Turn on power
www.lampolighting.com
fig.1
fig.2
fig.3
made in p.r.c.
Code
POWER
Volt
(V)
LED
Finish
Colore Led
Viewing
Angle
IP Value
FAFLAT30WRGB
30W
200-265V
SMD
bianco
RGB
120°
IP 65
FAFLAT50WRGB
50W
200-265V
SMD
bianco
RGB
120°
IP 65
TECHNICAL DATA
parallelo
outdoor
dimmerabile
ENG
32 mm
35 mm
193 mm
233 mm
141 mm
163 mm
Versione 30W
Versione 50W
30W version