background image

 

AquaPhoenix Scientific – WaterLink Spin Touch® Guide   

 6 

Cooling water, 4339, disk unspun, upside down

: The color in the wells is the dried reagent ready for 

testing and is normal of an unused disk. 

 

Calcium Hardness, chamber 4 

Total Iron bead, chamber 9 

Blank 

chamber

 

Dry pH reagent, 

chamber

 1 

 

 

 

 

How to read a disk lot number and other disk foil information: 

 

Series 

Product code  

Expiration date, two years and one month 
after disks were made 

Room disks were made in (Room 3) 

Last number of year disks were made (2018) 

 
 

Three digit day disks were made (029

th

 day) 

 

 

 

 

Summary of Contents for Water Link Spin Touch CW

Page 1: ...9 Tests in 60 Seconds FAQ...

Page 2: ...meter used in water testing The multiple parameters and spinning disk present unique approaches to testing However the disk is similar to other test methods like drop count titrations and colorimetric...

Page 3: ...photometer The test results are fairly precise but can be limited at times in precision The tests are highly accurate meaning you can get consistent trends over time Finally the disks are very easy to...

Page 4: ...or chlorine High level of salts and quats can affect readings My hardness numbers appear to be off what can be interfering with this Metals copper iron manganese can interfere with the hardness test U...

Page 5: ...l reagent colors Images of common problems Below is a typical spin disk with chamber numbers and parts labeled Distribution channel Fill chamber D Shaped hole Total Iron with white bead Over flow cham...

Page 6: ...e 5 The diagram for a 4339 cooling water disk is shown below Each chamber is numbered so chamber 1 is free chlorine chamber 2 is Alkalinity etc This is an example of a cooling tower disk after spin ou...

Page 7: ...l of an unused disk Calcium Hardness chamber 4 Total Iron bead chamber 9 Blank chamber Dry pH reagent chamber 1 How to read a disk lot number and other disk foil information Series Product code Expira...

Page 8: ...orine Bromine Well 1 Colorless Very low Low Medium High Alkalinity Well 2 No alkalinty Yellow low lime green Medium green High blue The alkalinity reagent well of a spun disk should never be colorless...

Page 9: ...Low Range Total Hardness Well 5 Colorless Very low Low High High Range Total Hardness Well 6 Colorless Very low Low Medium High Total Chlorine Well 7 Colorless Very Low Low Medium High Well 8 Empty I...

Page 10: ...o running the disk as the incorrect sequence meter calibration issues or a bubble in the blank chamber due to inaccurate filling of the disk see images below No alkalinty Yellow low lime green Medium...

Page 11: ...iny edges A worn hub right will have dull rounded edges that look more grey than the rest of the hub In cases of severe hub wear data may spike or read inaccuratly The hub on the right caused poor met...

Reviews: