PROCEDURE C - REGENERATION OF RESIN IN TOP CHAMBER
Follow manufacturers’ insstructions for regeneration of media. Cation exchange resin
may be regenerated in the following manner. NOTE: Due to build up of air pressure, it
is not possible to regenerate both chambers at the same time. Follow steps 1-8 to
regenerate top chamber, then procedure D to regenerate bottom chamber.
Clean
threaded area
completely
and replace
black plug in
top of
softener.
6.
At this point the resin in the top chamber should be completely
regenerated.
9.
Wash resin with
approximately 1
gallon of tap water.
8.
Attach adapter
to faucet.
7.
Remove
black plug
from top of
softener.
2.
Prepare salt
solution by
dissolving about
½ pound of salt
(sodium
chloride) in 1
quart of water.
1.
Allow to stand for about 30
minutes.
4.
30
MINUT
ES
Clamp outlet
tube.
Add salt
solution until
top chamber is
completely
full.
3.
Unclamp outlet tube
and allow salt
solution to run to
waste.
5.